ABAP Select data from SAP table ROIUX6_WY_OG001_SFHDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUX6_WY_OG001_SFHDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUX6_WY_OG001_SFHDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUX6_WY_OG001_SFHDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUX6_WY_OG001_SFHDR TYPE STANDARD TABLE OF ROIUX6_WY_OG001_SFHDR,
      WA_ROIUX6_WY_OG001_SFHDR TYPE ROIUX6_WY_OG001_SFHDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUX6_WY_OG001_SFHDR> TYPE ROIUX6_WY_OG001_SFHDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUX6_WY_OG001_SFHDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUX6_WY_OG001_SFHDR
  INTO TABLE IT_ROIUX6_WY_OG001_SFHDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUX6_WY_OG001_SFHDR
*  INTO TABLE @DATA(IT_ROIUX6_WY_OG001_SFHDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUX6_WY_OG001_SFHDR INDEX 1 INTO DATA(WA_ROIUX6_WY_OG001_SFHDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUX6_WY_OG001_SFHDR ASSIGNING <ROIUX6_WY_OG001_SFHDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUX6_WY_OG001_SFHDR>-TAXPAYER_NUMBER = 1.
<ROIUX6_WY_OG001_SFHDR>-TAXPAYER_NAME = 1.
<ROIUX6_WY_OG001_SFHDR>-ADDRESS_LINE1 = 1.
<ROIUX6_WY_OG001_SFHDR>-ADDRESS_LINE2 = 1.
<ROIUX6_WY_OG001_SFHDR>-OIL_GAS_INDICATOR = 1.
ENDLOOP.

LOOP AT IT_ROIUX6_WY_OG001_SFHDR INTO WA_ROIUX6_WY_OG001_SFHDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUX6_WY_OG001_SFHDR-REPORT_FREQUENCY, sy-vline,
WA_ROIUX6_WY_OG001_SFHDR-RPT_DT, sy-vline,
WA_ROIUX6_WY_OG001_SFHDR-PRODUCTION_PRD, sy-vline,
WA_ROIUX6_WY_OG001_SFHDR-PERIOD_ENDING, sy-vline,
WA_ROIUX6_WY_OG001_SFHDR-CONTACT_PHONE_NO, sy-vline,
WA_ROIUX6_WY_OG001_SFHDR-CONTACT_EMAIL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUX6_WY_OG001_SFHDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUX6_WY_OG001_SFHDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUX6_WY_OG001_SFHDR INTO WA_ROIUX6_WY_OG001_SFHDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI, internal->external for field RPT_DT CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_ROIUX6_WY_OG001_SFHDR-RPT_DT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_OG001_SFHDR-RPT_DT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUX6_WY_OG001_SFHDR_STR,
TAXPAYER_NUMBER TYPE STRING,
TAXPAYER_NAME TYPE STRING,
ADDRESS_LINE1 TYPE STRING,
ADDRESS_LINE2 TYPE STRING,
OIL_GAS_INDICATOR TYPE STRING,
REPORT_FREQUENCY TYPE STRING,
RPT_DT TYPE STRING,
PRODUCTION_PRD TYPE STRING,
PERIOD_ENDING TYPE STRING,
CONTACT_PHONE_NO TYPE STRING,
CONTACT_EMAIL TYPE STRING,
TAX_RATE_OIL TYPE STRING,
TAX_RATE_GAS TYPE STRING,
TAX_RATE_NGL TYPE STRING,
PG_GROSS_VOL_OIL TYPE STRING,
PG_GROSS_VOL_GAS TYPE STRING,
PG_EXEMPT_VOL_OIL TYPE STRING,
PG_EXEMPT_VOL_GAS TYPE STRING,
PG_PLANT_SHRINK_VOL TYPE STRING,
PG_TAX_VOL_OIL TYPE STRING,
PG_TAX_VOL_GAS TYPE STRING,
PG_TAX_VOL_NGL TYPE STRING,
PG_TAX_VAL_OIL TYPE STRING,
PG_TAX_VAL_GAS TYPE STRING,
PG_TAX_VAL_NGL TYPE STRING,
TOT_TAX_VAL_OIL TYPE STRING,
TOT_TAX_VAL_GAS TYPE STRING,
TOT_TAX_VAL_NGL TYPE STRING,
NET_TAX_VAL_OIL TYPE STRING,
NET_TAX_VAL_GAS TYPE STRING,
NET_TAX_VAL_NGL TYPE STRING,
TAX_DUE_OIL TYPE STRING,
TAX_DUE_GAS TYPE STRING,
TAX_DUE_NGL TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUX6_WY_OG001_SFHDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAXPAYER_NUMBER sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAXPAYER_NAME sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-ADDRESS_LINE1 sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-ADDRESS_LINE2 sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-OIL_GAS_INDICATOR sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-REPORT_FREQUENCY sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-RPT_DT sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PRODUCTION_PRD sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PERIOD_ENDING sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-CONTACT_PHONE_NO sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-CONTACT_EMAIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_RATE_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_RATE_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_RATE_NGL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_GROSS_VOL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_GROSS_VOL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_EXEMPT_VOL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_EXEMPT_VOL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_PLANT_SHRINK_VOL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VOL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VOL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VOL_NGL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VAL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VAL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-PG_TAX_VAL_NGL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TOT_TAX_VAL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TOT_TAX_VAL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TOT_TAX_VAL_NGL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-NET_TAX_VAL_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-NET_TAX_VAL_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-NET_TAX_VAL_NGL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_DUE_OIL sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_DUE_GAS sy-vline
WA_ROIUX6_WY_OG001_SFHDR_STR-TAX_DUE_NGL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.