ABAP Select data from SAP table ROIUY1_TX_AM1A_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUY1_TX_AM1A_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUY1_TX_AM1A_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUY1_TX_AM1A_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUY1_TX_AM1A_D TYPE STANDARD TABLE OF ROIUY1_TX_AM1A_D,
      WA_ROIUY1_TX_AM1A_D TYPE ROIUY1_TX_AM1A_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUY1_TX_AM1A_D> TYPE ROIUY1_TX_AM1A_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUY1_TX_AM1A_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUY1_TX_AM1A_D
  INTO TABLE IT_ROIUY1_TX_AM1A_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUY1_TX_AM1A_D
*  INTO TABLE @DATA(IT_ROIUY1_TX_AM1A_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUY1_TX_AM1A_D INDEX 1 INTO DATA(WA_ROIUY1_TX_AM1A_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUY1_TX_AM1A_D ASSIGNING <ROIUY1_TX_AM1A_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUY1_TX_AM1A_D>-ST_LEASE = 1.
<ROIUY1_TX_AM1A_D>-PROD_YYYYMM = 1.
<ROIUY1_TX_AM1A_D>-AMND_YY = 1.
<ROIUY1_TX_AM1A_D>-AMND_MM = 1.
<ROIUY1_TX_AM1A_D>-OIL_GAS = 1.
ENDLOOP.

LOOP AT IT_ROIUY1_TX_AM1A_D INTO WA_ROIUY1_TX_AM1A_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUY1_TX_AM1A_D-BEGSTK_O, sy-vline,
WA_ROIUY1_TX_AM1A_D-BEGSTK_N, sy-vline,
WA_ROIUY1_TX_AM1A_D-GROSSPROD_O, sy-vline,
WA_ROIUY1_TX_AM1A_D-GROSSPROD_N, sy-vline,
WA_ROIUY1_TX_AM1A_D-PIPELINE_O, sy-vline,
WA_ROIUY1_TX_AM1A_D-PIPELINE_N, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUY1_TX_AM1A_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUY1_TX_AM1A_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUY1_TX_AM1A_D INTO WA_ROIUY1_TX_AM1A_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUY1_TX_AM1A_D_STR,
ST_LEASE TYPE STRING,
PROD_YYYYMM TYPE STRING,
AMND_YY TYPE STRING,
AMND_MM TYPE STRING,
OIL_GAS TYPE STRING,
BEGSTK_O TYPE STRING,
BEGSTK_N TYPE STRING,
GROSSPROD_O TYPE STRING,
GROSSPROD_N TYPE STRING,
PIPELINE_O TYPE STRING,
PIPELINE_N TYPE STRING,
TRUCKS_O TYPE STRING,
TRUCKS_N TYPE STRING,
CODE1 TYPE STRING,
CIR_OIL_O TYPE STRING,
CIR_OIL_N TYPE STRING,
CODE2 TYPE STRING,
SKIM_OIL_O TYPE STRING,
SKIM_OIL_N TYPE STRING,
CODE3 TYPE STRING,
ENDSTK_O TYPE STRING,
ENDSTK_N TYPE STRING,
NETBARLS_N TYPE STRING,
NETBARLS_O TYPE STRING,
API_N TYPE STRING,
API_O TYPE STRING,
MARVALUE_O TYPE STRING,
MARVALUE_N TYPE STRING,
ROYDEC_N TYPE STRING,
ROYDEC_O TYPE STRING,
ROYDUE_O TYPE STRING,
ROYDUE_N TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUY1_TX_AM1A_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ST_LEASE sy-vline
WA_ROIUY1_TX_AM1A_D_STR-PROD_YYYYMM sy-vline
WA_ROIUY1_TX_AM1A_D_STR-AMND_YY sy-vline
WA_ROIUY1_TX_AM1A_D_STR-AMND_MM sy-vline
WA_ROIUY1_TX_AM1A_D_STR-OIL_GAS sy-vline
WA_ROIUY1_TX_AM1A_D_STR-BEGSTK_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-BEGSTK_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-GROSSPROD_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-GROSSPROD_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-PIPELINE_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-PIPELINE_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-TRUCKS_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-TRUCKS_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-CODE1 sy-vline
WA_ROIUY1_TX_AM1A_D_STR-CIR_OIL_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-CIR_OIL_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-CODE2 sy-vline
WA_ROIUY1_TX_AM1A_D_STR-SKIM_OIL_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-SKIM_OIL_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-CODE3 sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ENDSTK_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ENDSTK_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-NETBARLS_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-NETBARLS_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-API_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-API_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-MARVALUE_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-MARVALUE_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ROYDEC_N sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ROYDEC_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ROYDUE_O sy-vline
WA_ROIUY1_TX_AM1A_D_STR-ROYDUE_N sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.