ABAP Select data from SAP table ROXBC90115 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROXBC90115 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROXBC90115. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROXBC90115 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROXBC90115 TYPE STANDARD TABLE OF ROXBC90115, WA_ROXBC90115 TYPE ROXBC90115, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROXBC90115> TYPE ROXBC90115. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROXBC90115. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROXBC90115 INTO TABLE IT_ROXBC90115. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROXBC90115 * INTO TABLE @DATA(IT_ROXBC901152). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROXBC90115 INDEX 1 INTO DATA(WA_ROXBC901152). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROXBC90115 ASSIGNING <ROXBC90115>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROXBC90115>-GUID = 1.
<ROXBC90115>-MSGTY = 1.
<ROXBC90115>-MSGID = 1.
<ROXBC90115>-MSGNO = 1.
<ROXBC90115>-MSGV1 = 1.
ENDLOOP. LOOP AT IT_ROXBC90115 INTO WA_ROXBC90115. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROXBC90115-MSGV2, sy-vline,
WA_ROXBC90115-MSGV3, sy-vline,
WA_ROXBC90115-MSGV4, sy-vline,
WA_ROXBC90115-MESSAGE1, sy-vline,
WA_ROXBC90115-MESSAGE2, sy-vline,
WA_ROXBC90115-MESSAGE3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROXBC90115 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROXBC90115 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROXBC90115 INTO WA_ROXBC90115. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROXBC90115_STR,
GUID TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
MESSAGE1 TYPE STRING,
MESSAGE2 TYPE STRING,
MESSAGE3 TYPE STRING,
MESSAGE4 TYPE STRING,
MESSAGE5 TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROXBC90115_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROXBC90115_STR-GUID sy-vline
WA_ROXBC90115_STR-MSGTY sy-vline
WA_ROXBC90115_STR-MSGID sy-vline
WA_ROXBC90115_STR-MSGNO sy-vline
WA_ROXBC90115_STR-MSGV1 sy-vline
WA_ROXBC90115_STR-MSGV2 sy-vline
WA_ROXBC90115_STR-MSGV3 sy-vline
WA_ROXBC90115_STR-MSGV4 sy-vline
WA_ROXBC90115_STR-MESSAGE1 sy-vline
WA_ROXBC90115_STR-MESSAGE2 sy-vline
WA_ROXBC90115_STR-MESSAGE3 sy-vline
WA_ROXBC90115_STR-MESSAGE4 sy-vline
WA_ROXBC90115_STR-MESSAGE5 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.