ABAP Select data from SAP table RPBEN_ESS_GENERIC_PLAN_DETAIL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPBEN_ESS_GENERIC_PLAN_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPBEN_ESS_GENERIC_PLAN_DETAIL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RPBEN_ESS_GENERIC_PLAN_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RPBEN_ESS_GENERIC_PLAN_DETAIL TYPE STANDARD TABLE OF RPBEN_ESS_GENERIC_PLAN_DETAIL, WA_RPBEN_ESS_GENERIC_PLAN_DETAIL TYPE RPBEN_ESS_GENERIC_PLAN_DETAIL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RPBEN_ESS_GENERIC_PLAN_DETAIL> TYPE RPBEN_ESS_GENERIC_PLAN_DETAIL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RPBEN_ESS_GENERIC_PLAN_DETAIL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RPBEN_ESS_GENERIC_PLAN_DETAIL INTO TABLE IT_RPBEN_ESS_GENERIC_PLAN_DETAIL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RPBEN_ESS_GENERIC_PLAN_DETAIL * INTO TABLE @DATA(IT_RPBEN_ESS_GENERIC_PLAN_DETAIL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RPBEN_ESS_GENERIC_PLAN_DETAIL INDEX 1 INTO DATA(WA_RPBEN_ESS_GENERIC_PLAN_DETAIL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RPBEN_ESS_GENERIC_PLAN_DETAIL ASSIGNING <RPBEN_ESS_GENERIC_PLAN_DETAIL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPBEN_ESS_GENERIC_PLAN_DETAIL>-BAREA = 1.
<RPBEN_ESS_GENERIC_PLAN_DETAIL>-BPCAT = 1.
<RPBEN_ESS_GENERIC_PLAN_DETAIL>-BPLAN = 1.
<RPBEN_ESS_GENERIC_PLAN_DETAIL>-BEGDA = 1.
<RPBEN_ESS_GENERIC_PLAN_DETAIL>-ENDDA = 1.
ENDLOOP. LOOP AT IT_RPBEN_ESS_GENERIC_PLAN_DETAIL INTO WA_RPBEN_ESS_GENERIC_PLAN_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-TXT_OPTION, sy-vline,
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-TXT_DEPCOV, sy-vline,
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-TXT_MODEL, sy-vline,
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-SPRPS, sy-vline,
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-EOGRP, sy-vline,
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL-EOIRQ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPBEN_ESS_GENERIC_PLAN_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPBEN_ESS_GENERIC_PLAN_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPBEN_ESS_GENERIC_PLAN_DETAIL INTO WA_RPBEN_ESS_GENERIC_PLAN_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR,
BAREA TYPE STRING,
BPCAT TYPE STRING,
BPLAN TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
TXT_OPTION TYPE STRING,
TXT_DEPCOV TYPE STRING,
TXT_MODEL TYPE STRING,
SPRPS TYPE STRING,
EOGRP TYPE STRING,
EOIRQ TYPE STRING,
EOIPR TYPE STRING,
CURRE TYPE STRING,
PERIO TYPE STRING,
TXT_PERIOD TYPE STRING,
CSTCR TYPE STRING,
PRETX TYPE STRING,
EECST TYPE STRING,
PTCST TYPE STRING,
IMINC TYPE STRING,
ERCST TYPE STRING,
ERNOC TYPE STRING,
FLXCR TYPE STRING,
BSCOV TYPE STRING,
ADDUN TYPE STRING,
ADDNO TYPE STRING,
COVAM TYPE STRING,
CRAMT TYPE STRING,
PREOK TYPE STRING,
PSTOK TYPE STRING,
BPROK TYPE STRING,
BPTOK TYPE STRING,
AMTOK TYPE STRING,
PCTOK TYPE STRING,
UNTOK TYPE STRING,
EEPCT TYPE STRING,
EEAMT TYPE STRING,
EEUNT TYPE STRING,
EEPRE TYPE STRING,
PTPCT TYPE STRING,
PTAMT TYPE STRING,
PTUNT TYPE STRING,
EEPST TYPE STRING,
ROLLO TYPE STRING,
PSTTX TYPE STRING,
BCPCT TYPE STRING,
BCAMT TYPE STRING,
BCUNT TYPE STRING,
BPPCT TYPE STRING,
BPAMT TYPE STRING,
BPUNT TYPE STRING,
BROLL TYPE STRING,
BPTTX TYPE STRING,
CUNIT TYPE STRING,
PDFIX TYPE STRING,
PDBEG TYPE STRING,
PDEND TYPE STRING,
PYBEG TYPE STRING,
PYEND TYPE STRING,
CAMNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BAREA sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPCAT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPLAN sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BEGDA sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ENDDA sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-TXT_OPTION sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-TXT_DEPCOV sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-TXT_MODEL sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-SPRPS sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EOGRP sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EOIRQ sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EOIPR sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-CURRE sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PERIO sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-TXT_PERIOD sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-CSTCR sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PRETX sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EECST sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PTCST sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-IMINC sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ERCST sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ERNOC sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-FLXCR sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BSCOV sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ADDUN sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ADDNO sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-COVAM sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-CRAMT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PREOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PSTOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPROK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPTOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-AMTOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PCTOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-UNTOK sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EEPCT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EEAMT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EEUNT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EEPRE sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PTPCT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PTAMT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PTUNT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-EEPST sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-ROLLO sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PSTTX sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BCPCT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BCAMT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BCUNT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPPCT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPAMT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPUNT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BROLL sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-BPTTX sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-CUNIT sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PDFIX sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PDBEG sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PDEND sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PYBEG sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-PYEND sy-vline
WA_RPBEN_ESS_GENERIC_PLAN_DETAIL_STR-CAMNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.