ABAP Select data from SAP table RPBEN_SE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPBEN_SE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPBEN_SE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPBEN_SE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPBEN_SE TYPE STANDARD TABLE OF RPBEN_SE,
      WA_RPBEN_SE TYPE RPBEN_SE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPBEN_SE> TYPE RPBEN_SE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPBEN_SE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPBEN_SE
  INTO TABLE IT_RPBEN_SE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPBEN_SE
*  INTO TABLE @DATA(IT_RPBEN_SE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPBEN_SE INDEX 1 INTO DATA(WA_RPBEN_SE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPBEN_SE ASSIGNING <RPBEN_SE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPBEN_SE>-PERNR = 1.
<RPBEN_SE>-BEGDA = 1.
<RPBEN_SE>-ENDDA = 1.
<RPBEN_SE>-BAREA = 1.
<RPBEN_SE>-PLTYP = 1.
ENDLOOP.

LOOP AT IT_RPBEN_SE INTO WA_RPBEN_SE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPBEN_SE-BPLAN, sy-vline,
WA_RPBEN_SE-ELIDT, sy-vline,
WA_RPBEN_SE-ELDTO, sy-vline,
WA_RPBEN_SE-PARDT, sy-vline,
WA_RPBEN_SE-ENRTY, sy-vline,
WA_RPBEN_SE-EVENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPBEN_SE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPBEN_SE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPBEN_SE INTO WA_RPBEN_SE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPBEN_SE_STR,
PERNR TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
BAREA TYPE STRING,
PLTYP TYPE STRING,
BPLAN TYPE STRING,
ELIDT TYPE STRING,
ELDTO TYPE STRING,
PARDT TYPE STRING,
ENRTY TYPE STRING,
EVENT TYPE STRING,
CURRE TYPE STRING,
PERIO TYPE STRING,
LEVL1 TYPE STRING,
SALOV TYPE STRING,
COVOV TYPE STRING,
ADDNO TYPE STRING,
EEPCT TYPE STRING,
EEAMT TYPE STRING,
EEUNT TYPE STRING,
PTPCT TYPE STRING,
PTAMT TYPE STRING,
PTUNT TYPE STRING,
PSTTX TYPE STRING,
PRETX TYPE STRING,
BCAMT TYPE STRING,
BCPCT TYPE STRING,
BCUNT TYPE STRING,
BPAMT TYPE STRING,
BPPCT TYPE STRING,
BPUNT TYPE STRING,
BPTTX TYPE STRING,
CRAMO TYPE STRING,
RLPTY TYPE STRING,
CHG_BPLAN TYPE STRING,
ADD_BPLAN TYPE STRING,
DEL_BPLAN TYPE STRING,
CHG_LEVL1 TYPE STRING,
INC_ADDNO TYPE STRING,
DEC_ADDNO TYPE STRING,
INC_PRECO TYPE STRING,
DEC_PRECO TYPE STRING,
INC_PSTCO TYPE STRING,
DEC_PSTCO TYPE STRING,
INC_BPRCO TYPE STRING,
DEC_BPRCO TYPE STRING,
INC_BPTCO TYPE STRING,
DEC_BPTCO TYPE STRING,
CHG_PSTTX TYPE STRING,
CHG_BPTTX TYPE STRING,
CHG_PRETX TYPE STRING,
CHG_DEPDT TYPE STRING,
CHG_BENEF TYPE STRING,
CHG_INVES TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPBEN_SE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPBEN_SE_STR-PERNR sy-vline
WA_RPBEN_SE_STR-BEGDA sy-vline
WA_RPBEN_SE_STR-ENDDA sy-vline
WA_RPBEN_SE_STR-BAREA sy-vline
WA_RPBEN_SE_STR-PLTYP sy-vline
WA_RPBEN_SE_STR-BPLAN sy-vline
WA_RPBEN_SE_STR-ELIDT sy-vline
WA_RPBEN_SE_STR-ELDTO sy-vline
WA_RPBEN_SE_STR-PARDT sy-vline
WA_RPBEN_SE_STR-ENRTY sy-vline
WA_RPBEN_SE_STR-EVENT sy-vline
WA_RPBEN_SE_STR-CURRE sy-vline
WA_RPBEN_SE_STR-PERIO sy-vline
WA_RPBEN_SE_STR-LEVL1 sy-vline
WA_RPBEN_SE_STR-SALOV sy-vline
WA_RPBEN_SE_STR-COVOV sy-vline
WA_RPBEN_SE_STR-ADDNO sy-vline
WA_RPBEN_SE_STR-EEPCT sy-vline
WA_RPBEN_SE_STR-EEAMT sy-vline
WA_RPBEN_SE_STR-EEUNT sy-vline
WA_RPBEN_SE_STR-PTPCT sy-vline
WA_RPBEN_SE_STR-PTAMT sy-vline
WA_RPBEN_SE_STR-PTUNT sy-vline
WA_RPBEN_SE_STR-PSTTX sy-vline
WA_RPBEN_SE_STR-PRETX sy-vline
WA_RPBEN_SE_STR-BCAMT sy-vline
WA_RPBEN_SE_STR-BCPCT sy-vline
WA_RPBEN_SE_STR-BCUNT sy-vline
WA_RPBEN_SE_STR-BPAMT sy-vline
WA_RPBEN_SE_STR-BPPCT sy-vline
WA_RPBEN_SE_STR-BPUNT sy-vline
WA_RPBEN_SE_STR-BPTTX sy-vline
WA_RPBEN_SE_STR-CRAMO sy-vline
WA_RPBEN_SE_STR-RLPTY sy-vline
WA_RPBEN_SE_STR-CHG_BPLAN sy-vline
WA_RPBEN_SE_STR-ADD_BPLAN sy-vline
WA_RPBEN_SE_STR-DEL_BPLAN sy-vline
WA_RPBEN_SE_STR-CHG_LEVL1 sy-vline
WA_RPBEN_SE_STR-INC_ADDNO sy-vline
WA_RPBEN_SE_STR-DEC_ADDNO sy-vline
WA_RPBEN_SE_STR-INC_PRECO sy-vline
WA_RPBEN_SE_STR-DEC_PRECO sy-vline
WA_RPBEN_SE_STR-INC_PSTCO sy-vline
WA_RPBEN_SE_STR-DEC_PSTCO sy-vline
WA_RPBEN_SE_STR-INC_BPRCO sy-vline
WA_RPBEN_SE_STR-DEC_BPRCO sy-vline
WA_RPBEN_SE_STR-INC_BPTCO sy-vline
WA_RPBEN_SE_STR-DEC_BPTCO sy-vline
WA_RPBEN_SE_STR-CHG_PSTTX sy-vline
WA_RPBEN_SE_STR-CHG_BPTTX sy-vline
WA_RPBEN_SE_STR-CHG_PRETX sy-vline
WA_RPBEN_SE_STR-CHG_DEPDT sy-vline
WA_RPBEN_SE_STR-CHG_BENEF sy-vline
WA_RPBEN_SE_STR-CHG_INVES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.