ABAP Select data from SAP table RPCSVBD0_PDF_STRU into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPCSVBD0_PDF_STRU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPCSVBD0_PDF_STRU. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RPCSVBD0_PDF_STRU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RPCSVBD0_PDF_STRU TYPE STANDARD TABLE OF RPCSVBD0_PDF_STRU, WA_RPCSVBD0_PDF_STRU TYPE RPCSVBD0_PDF_STRU, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RPCSVBD0_PDF_STRU> TYPE RPCSVBD0_PDF_STRU. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RPCSVBD0_PDF_STRU. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RPCSVBD0_PDF_STRU INTO TABLE IT_RPCSVBD0_PDF_STRU. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RPCSVBD0_PDF_STRU * INTO TABLE @DATA(IT_RPCSVBD0_PDF_STRU2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RPCSVBD0_PDF_STRU INDEX 1 INTO DATA(WA_RPCSVBD0_PDF_STRU2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RPCSVBD0_PDF_STRU ASSIGNING <RPCSVBD0_PDF_STRU>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPCSVBD0_PDF_STRU>-LFD_NR = 1.
<RPCSVBD0_PDF_STRU>-LIART = 1.
<RPCSVBD0_PDF_STRU>-WAERS = 1.
<RPCSVBD0_PDF_STRU>-PERNR = 1.
<RPCSVBD0_PDF_STRU>-PERID = 1.
ENDLOOP. LOOP AT IT_RPCSVBD0_PDF_STRU INTO WA_RPCSVBD0_PDF_STRU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RPCSVBD0_PDF_STRU-PABRJ, sy-vline,
WA_RPCSVBD0_PDF_STRU-PABRP, sy-vline,
WA_RPCSVBD0_PDF_STRU-CNAME, sy-vline,
WA_RPCSVBD0_PDF_STRU-RVNUM, sy-vline,
WA_RPCSVBD0_PDF_STRU-MITNR, sy-vline,
WA_RPCSVBD0_PDF_STRU-INTER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPCSVBD0_PDF_STRU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPCSVBD0_PDF_STRU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPCSVBD0_PDF_STRU INTO WA_RPCSVBD0_PDF_STRU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field PABRJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RPCSVBD0_PDF_STRU-PABRJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPCSVBD0_PDF_STRU-PABRJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPCSVBD0_PDF_STRU_STR,
LFD_NR TYPE STRING,
LIART TYPE STRING,
WAERS TYPE STRING,
PERNR TYPE STRING,
PERID TYPE STRING,
PABRJ TYPE STRING,
PABRP TYPE STRING,
CNAME TYPE STRING,
RVNUM TYPE STRING,
MITNR TYPE STRING,
INTER TYPE STRING,
SRTFD TYPE STRING,
BGRS TYPE STRING,
SELBSTZ TYPE STRING,
MFBEZ TYPE STRING,
SVGVD TYPE STRING,
ANZ01 TYPE STRING,
ANZ02 TYPE STRING,
ANZ03 TYPE STRING,
ANZ04 TYPE STRING,
BTR01 TYPE STRING,
BTR02 TYPE STRING,
BTR03 TYPE STRING,
BTR04 TYPE STRING,
BTR05 TYPE STRING,
BTR06 TYPE STRING,
BTR51 TYPE STRING,
BTR52 TYPE STRING,
BTR53 TYPE STRING,
PSTGF TYPE STRING,
STBRU TYPE STRING,
KV_RENT TYPE STRING,
PV_RENT TYPE STRING,
BTG10 TYPE STRING,
BTG20 TYPE STRING,
BTG30 TYPE STRING,
BTG40 TYPE STRING,
BTN10 TYPE STRING,
BTN20 TYPE STRING,
BTN30 TYPE STRING,
BTN40 TYPE STRING,
STATUS TYPE STRING,
ZEIL3 TYPE STRING,
ANSTAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPCSVBD0_PDF_STRU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPCSVBD0_PDF_STRU_STR-LFD_NR sy-vline
WA_RPCSVBD0_PDF_STRU_STR-LIART sy-vline
WA_RPCSVBD0_PDF_STRU_STR-WAERS sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PERNR sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PERID sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PABRJ sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PABRP sy-vline
WA_RPCSVBD0_PDF_STRU_STR-CNAME sy-vline
WA_RPCSVBD0_PDF_STRU_STR-RVNUM sy-vline
WA_RPCSVBD0_PDF_STRU_STR-MITNR sy-vline
WA_RPCSVBD0_PDF_STRU_STR-INTER sy-vline
WA_RPCSVBD0_PDF_STRU_STR-SRTFD sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BGRS sy-vline
WA_RPCSVBD0_PDF_STRU_STR-SELBSTZ sy-vline
WA_RPCSVBD0_PDF_STRU_STR-MFBEZ sy-vline
WA_RPCSVBD0_PDF_STRU_STR-SVGVD sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ANZ01 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ANZ02 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ANZ03 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ANZ04 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR01 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR02 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR03 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR04 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR05 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR06 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR51 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR52 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTR53 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PSTGF sy-vline
WA_RPCSVBD0_PDF_STRU_STR-STBRU sy-vline
WA_RPCSVBD0_PDF_STRU_STR-KV_RENT sy-vline
WA_RPCSVBD0_PDF_STRU_STR-PV_RENT sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTG10 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTG20 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTG30 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTG40 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTN10 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTN20 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTN30 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-BTN40 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-STATUS sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ZEIL3 sy-vline
WA_RPCSVBD0_PDF_STRU_STR-ANSTAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.