ABAP Select data from SAP table RPLM_TS_POWL_NOTIF_GEN_DEF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPLM_TS_POWL_NOTIF_GEN_DEF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPLM_TS_POWL_NOTIF_GEN_DEF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RPLM_TS_POWL_NOTIF_GEN_DEF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RPLM_TS_POWL_NOTIF_GEN_DEF TYPE STANDARD TABLE OF RPLM_TS_POWL_NOTIF_GEN_DEF, WA_RPLM_TS_POWL_NOTIF_GEN_DEF TYPE RPLM_TS_POWL_NOTIF_GEN_DEF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RPLM_TS_POWL_NOTIF_GEN_DEF> TYPE RPLM_TS_POWL_NOTIF_GEN_DEF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RPLM_TS_POWL_NOTIF_GEN_DEF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RPLM_TS_POWL_NOTIF_GEN_DEF INTO TABLE IT_RPLM_TS_POWL_NOTIF_GEN_DEF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RPLM_TS_POWL_NOTIF_GEN_DEF * INTO TABLE @DATA(IT_RPLM_TS_POWL_NOTIF_GEN_DEF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RPLM_TS_POWL_NOTIF_GEN_DEF INDEX 1 INTO DATA(WA_RPLM_TS_POWL_NOTIF_GEN_DEF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RPLM_TS_POWL_NOTIF_GEN_DEF ASSIGNING <RPLM_TS_POWL_NOTIF_GEN_DEF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPLM_TS_POWL_NOTIF_GEN_DEF>-QMNUM = 1.
<RPLM_TS_POWL_NOTIF_GEN_DEF>-QMTXT = 1.
<RPLM_TS_POWL_NOTIF_GEN_DEF>-STRMN = 1.
<RPLM_TS_POWL_NOTIF_GEN_DEF>-LTRMN = 1.
<RPLM_TS_POWL_NOTIF_GEN_DEF>-MATNR = 1.
ENDLOOP. LOOP AT IT_RPLM_TS_POWL_NOTIF_GEN_DEF INTO WA_RPLM_TS_POWL_NOTIF_GEN_DEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RPLM_TS_POWL_NOTIF_GEN_DEF-MATKTX, sy-vline,
WA_RPLM_TS_POWL_NOTIF_GEN_DEF-PRIOKX, sy-vline,
WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LIGHTS, sy-vline,
WA_RPLM_TS_POWL_NOTIF_GEN_DEF-KUNUM, sy-vline,
WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LIFNUM, sy-vline,
WA_RPLM_TS_POWL_NOTIF_GEN_DEF-HERSTELLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPLM_TS_POWL_NOTIF_GEN_DEF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPLM_TS_POWL_NOTIF_GEN_DEF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPLM_TS_POWL_NOTIF_GEN_DEF INTO WA_RPLM_TS_POWL_NOTIF_GEN_DEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-QMNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-KUNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIFNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LIFNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LIFNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field HERSTELLER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-HERSTELLER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-HERSTELLER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FERTAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-FERTAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-FERTAUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-VBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LS_KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LS_KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-LS_KDAUF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRUEFLOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-PRUEFLOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-PRUEFLOS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-EBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-VORNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field FERTVORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-FERTVORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-FERTVORNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MGEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_GEN_DEF-MGEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_GEN_DEF-MGEIN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPLM_TS_POWL_NOTIF_GEN_DEF_STR,
QMNUM TYPE STRING,
QMTXT TYPE STRING,
STRMN TYPE STRING,
LTRMN TYPE STRING,
MATNR TYPE STRING,
MATKTX TYPE STRING,
PRIOKX TYPE STRING,
LIGHTS TYPE STRING,
KUNUM TYPE STRING,
LIFNUM TYPE STRING,
HERSTELLER TYPE STRING,
QMART TYPE STRING,
QMNAM TYPE STRING,
AUFNR TYPE STRING,
FERTAUFNR TYPE STRING,
VBELN TYPE STRING,
LS_KDAUF TYPE STRING,
PRUEFLOS TYPE STRING,
EBELN TYPE STRING,
ARBPLWERK TYPE STRING,
ARBPL TYPE STRING,
ARBPL_I TYPE STRING,
VORNR TYPE STRING,
VORKTEXT TYPE STRING,
FERTVORNR TYPE STRING,
FERTVORKTX TYPE STRING,
CHARG TYPE STRING,
RKMNG TYPE STRING,
BZMNG TYPE STRING,
MGEIN TYPE STRING,
QMDAT TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
QMGRP TYPE STRING,
KTXTGR TYPE STRING,
QMCOD TYPE STRING,
KTXTCD TYPE STRING,
STTXT TYPE STRING,
USTXT TYPE STRING,
OBJNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMNUM sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-STRMN sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-LTRMN sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-MATNR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-MATKTX sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-PRIOKX sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-LIGHTS sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-KUNUM sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-LIFNUM sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-HERSTELLER sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMART sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMNAM sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-AUFNR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-FERTAUFNR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-VBELN sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-LS_KDAUF sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-PRUEFLOS sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-EBELN sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-ARBPLWERK sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-ARBPL sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-ARBPL_I sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-VORNR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-VORKTEXT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-FERTVORNR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-FERTVORKTX sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-CHARG sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-RKMNG sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-BZMNG sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-MGEIN sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMDAT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-ERNAM sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-ERDAT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMGRP sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-KTXTGR sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-QMCOD sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-KTXTCD sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-STTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-USTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_GEN_DEF_STR-OBJNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.