ABAP Select data from SAP table SAPWLSH1SH into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SAPWLSH1SH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SAPWLSH1SH. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SAPWLSH1SH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SAPWLSH1SH TYPE STANDARD TABLE OF SAPWLSH1SH, WA_SAPWLSH1SH TYPE SAPWLSH1SH, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SAPWLSH1SH> TYPE SAPWLSH1SH. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SAPWLSH1SH. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SAPWLSH1SH INTO TABLE IT_SAPWLSH1SH. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SAPWLSH1SH * INTO TABLE @DATA(IT_SAPWLSH1SH2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SAPWLSH1SH INDEX 1 INTO DATA(WA_SAPWLSH1SH2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SAPWLSH1SH ASSIGNING <SAPWLSH1SH>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SAPWLSH1SH>-RECNO = 1.
<SAPWLSH1SH>-DISPCNT = 1.
<SAPWLSH1SH>-DATE = 1.
<SAPWLSH1SH>-STARTDATE = 1.
<SAPWLSH1SH>-STARTTIME = 1.
ENDLOOP. LOOP AT IT_SAPWLSH1SH INTO WA_SAPWLSH1SH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SAPWLSH1SH-ENDDATE, sy-vline,
WA_SAPWLSH1SH-ENDTIME, sy-vline,
WA_SAPWLSH1SH-RESPTI, sy-vline,
WA_SAPWLSH1SH-CPUTI, sy-vline,
WA_SAPWLSH1SH-QUEUETI, sy-vline,
WA_SAPWLSH1SH-WPID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SAPWLSH1SH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SAPWLSH1SH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SAPWLSH1SH INTO WA_SAPWLSH1SH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SAPWLSH1SH_STR,
RECNO TYPE STRING,
DISPCNT TYPE STRING,
DATE TYPE STRING,
STARTDATE TYPE STRING,
STARTTIME TYPE STRING,
ENDDATE TYPE STRING,
ENDTIME TYPE STRING,
RESPTI TYPE STRING,
CPUTI TYPE STRING,
QUEUETI TYPE STRING,
WPID TYPE STRING,
TASKTYPE TYPE STRING,
TABLOAD TYPE STRING,
DYNPRONR TYPE STRING,
REPORT TYPE STRING,
ACCOUNT TYPE STRING,
MANDT TYPE STRING,
ROLLKEY TYPE STRING,
INPUTLEN TYPE STRING,
OUTPUTLEN TYPE STRING,
MAXROLL TYPE STRING,
MAXPAGE TYPE STRING,
ROLLINCNT TYPE STRING,
ROLLINTI TYPE STRING,
ROLLOUTCNT TYPE STRING,
ROLLOUTTI TYPE STRING,
LOCKCNT TYPE STRING,
LOCKTI TYPE STRING,
READDIRCNT TYPE STRING,
READDIRTI TYPE STRING,
READDIRREC TYPE STRING,
READDIRBUF TYPE STRING,
READSEQCNT TYPE STRING,
READSEQTI TYPE STRING,
READSEQREC TYPE STRING,
READSEQBUF TYPE STRING,
PHYREADCNT TYPE STRING,
INSCNT TYPE STRING,
INSTI TYPE STRING,
INSREC TYPE STRING,
PHYINSCNT TYPE STRING,
UPDCNT TYPE STRING,
UPDTI TYPE STRING,
UPDREC TYPE STRING,
PHYUPDCNT TYPE STRING,
DELCNT TYPE STRING,
DELTI TYPE STRING,
DELREC TYPE STRING,
PHYDELCNT TYPE STRING,
COMMITTI TYPE STRING,
GENERATETI TYPE STRING,
REPLOADTI TYPE STRING,
CUALOADTI TYPE STRING,
DYNPLOADTI TYPE STRING,
DSQLCNT TYPE STRING,
QUECNT TYPE STRING,
QUETI TYPE STRING,
DDICTI TYPE STRING,
RFCCNT TYPE STRING,
RFCTI TYPE STRING,
MEMSUM TYPE STRING,
PRIVSUM TYPE STRING,
USEDBYTES TYPE STRING,
MAXBYTES TYPE STRING,
MAXBYTESDI TYPE STRING,
PRIVMODE TYPE STRING,
WPRESTART TYPE STRING,
TRANSID TYPE STRING,
ROLLED_OUT TYPE STRING,
DBPROCCNT TYPE STRING,
DBPROCTI TYPE STRING,
LUW_INFO TYPE STRING,
SLI_CNT TYPE STRING,
STARTSTAMP TYPE STRING,
ENDSTAMP TYPE STRING,
GUITIME TYPE STRING,
GUICNT TYPE STRING,
GUINETTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_SAPWLSH1SH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SAPWLSH1SH_STR-RECNO sy-vline
WA_SAPWLSH1SH_STR-DISPCNT sy-vline
WA_SAPWLSH1SH_STR-DATE sy-vline
WA_SAPWLSH1SH_STR-STARTDATE sy-vline
WA_SAPWLSH1SH_STR-STARTTIME sy-vline
WA_SAPWLSH1SH_STR-ENDDATE sy-vline
WA_SAPWLSH1SH_STR-ENDTIME sy-vline
WA_SAPWLSH1SH_STR-RESPTI sy-vline
WA_SAPWLSH1SH_STR-CPUTI sy-vline
WA_SAPWLSH1SH_STR-QUEUETI sy-vline
WA_SAPWLSH1SH_STR-WPID sy-vline
WA_SAPWLSH1SH_STR-TASKTYPE sy-vline
WA_SAPWLSH1SH_STR-TABLOAD sy-vline
WA_SAPWLSH1SH_STR-DYNPRONR sy-vline
WA_SAPWLSH1SH_STR-REPORT sy-vline
WA_SAPWLSH1SH_STR-ACCOUNT sy-vline
WA_SAPWLSH1SH_STR-MANDT sy-vline
WA_SAPWLSH1SH_STR-ROLLKEY sy-vline
WA_SAPWLSH1SH_STR-INPUTLEN sy-vline
WA_SAPWLSH1SH_STR-OUTPUTLEN sy-vline
WA_SAPWLSH1SH_STR-MAXROLL sy-vline
WA_SAPWLSH1SH_STR-MAXPAGE sy-vline
WA_SAPWLSH1SH_STR-ROLLINCNT sy-vline
WA_SAPWLSH1SH_STR-ROLLINTI sy-vline
WA_SAPWLSH1SH_STR-ROLLOUTCNT sy-vline
WA_SAPWLSH1SH_STR-ROLLOUTTI sy-vline
WA_SAPWLSH1SH_STR-LOCKCNT sy-vline
WA_SAPWLSH1SH_STR-LOCKTI sy-vline
WA_SAPWLSH1SH_STR-READDIRCNT sy-vline
WA_SAPWLSH1SH_STR-READDIRTI sy-vline
WA_SAPWLSH1SH_STR-READDIRREC sy-vline
WA_SAPWLSH1SH_STR-READDIRBUF sy-vline
WA_SAPWLSH1SH_STR-READSEQCNT sy-vline
WA_SAPWLSH1SH_STR-READSEQTI sy-vline
WA_SAPWLSH1SH_STR-READSEQREC sy-vline
WA_SAPWLSH1SH_STR-READSEQBUF sy-vline
WA_SAPWLSH1SH_STR-PHYREADCNT sy-vline
WA_SAPWLSH1SH_STR-INSCNT sy-vline
WA_SAPWLSH1SH_STR-INSTI sy-vline
WA_SAPWLSH1SH_STR-INSREC sy-vline
WA_SAPWLSH1SH_STR-PHYINSCNT sy-vline
WA_SAPWLSH1SH_STR-UPDCNT sy-vline
WA_SAPWLSH1SH_STR-UPDTI sy-vline
WA_SAPWLSH1SH_STR-UPDREC sy-vline
WA_SAPWLSH1SH_STR-PHYUPDCNT sy-vline
WA_SAPWLSH1SH_STR-DELCNT sy-vline
WA_SAPWLSH1SH_STR-DELTI sy-vline
WA_SAPWLSH1SH_STR-DELREC sy-vline
WA_SAPWLSH1SH_STR-PHYDELCNT sy-vline
WA_SAPWLSH1SH_STR-COMMITTI sy-vline
WA_SAPWLSH1SH_STR-GENERATETI sy-vline
WA_SAPWLSH1SH_STR-REPLOADTI sy-vline
WA_SAPWLSH1SH_STR-CUALOADTI sy-vline
WA_SAPWLSH1SH_STR-DYNPLOADTI sy-vline
WA_SAPWLSH1SH_STR-DSQLCNT sy-vline
WA_SAPWLSH1SH_STR-QUECNT sy-vline
WA_SAPWLSH1SH_STR-QUETI sy-vline
WA_SAPWLSH1SH_STR-DDICTI sy-vline
WA_SAPWLSH1SH_STR-RFCCNT sy-vline
WA_SAPWLSH1SH_STR-RFCTI sy-vline
WA_SAPWLSH1SH_STR-MEMSUM sy-vline
WA_SAPWLSH1SH_STR-PRIVSUM sy-vline
WA_SAPWLSH1SH_STR-USEDBYTES sy-vline
WA_SAPWLSH1SH_STR-MAXBYTES sy-vline
WA_SAPWLSH1SH_STR-MAXBYTESDI sy-vline
WA_SAPWLSH1SH_STR-PRIVMODE sy-vline
WA_SAPWLSH1SH_STR-WPRESTART sy-vline
WA_SAPWLSH1SH_STR-TRANSID sy-vline
WA_SAPWLSH1SH_STR-ROLLED_OUT sy-vline
WA_SAPWLSH1SH_STR-DBPROCCNT sy-vline
WA_SAPWLSH1SH_STR-DBPROCTI sy-vline
WA_SAPWLSH1SH_STR-LUW_INFO sy-vline
WA_SAPWLSH1SH_STR-SLI_CNT sy-vline
WA_SAPWLSH1SH_STR-STARTSTAMP sy-vline
WA_SAPWLSH1SH_STR-ENDSTAMP sy-vline
WA_SAPWLSH1SH_STR-GUITIME sy-vline
WA_SAPWLSH1SH_STR-GUICNT sy-vline
WA_SAPWLSH1SH_STR-GUINETTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.