ABAP Select data from SAP table SATC_WL_FND_DV into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SATC_WL_FND_DV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SATC_WL_FND_DV. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SATC_WL_FND_DV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SATC_WL_FND_DV TYPE STANDARD TABLE OF SATC_WL_FND_DV, WA_SATC_WL_FND_DV TYPE SATC_WL_FND_DV, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SATC_WL_FND_DV> TYPE SATC_WL_FND_DV. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SATC_WL_FND_DV. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SATC_WL_FND_DV INTO TABLE IT_SATC_WL_FND_DV. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SATC_WL_FND_DV * INTO TABLE @DATA(IT_SATC_WL_FND_DV2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SATC_WL_FND_DV INDEX 1 INTO DATA(WA_SATC_WL_FND_DV2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SATC_WL_FND_DV ASSIGNING <SATC_WL_FND_DV>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SATC_WL_FND_DV>-WORKLIST_ID = 1.
<SATC_WL_FND_DV>-OBJ_NAME = 1.
<SATC_WL_FND_DV>-OBJ_TYPE = 1.
<SATC_WL_FND_DV>-MODULE_ID = 1.
<SATC_WL_FND_DV>-MODULE_MSG_KEY = 1.
ENDLOOP. LOOP AT IT_SATC_WL_FND_DV INTO WA_SATC_WL_FND_DV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SATC_WL_FND_DV-CHECKSUM, sy-vline,
WA_SATC_WL_FND_DV-CHANGED_ON, sy-vline,
WA_SATC_WL_FND_DV-PROCESSOR, sy-vline,
WA_SATC_WL_FND_DV-HAS_QUICKFIXES, sy-vline,
WA_SATC_WL_FND_DV-EXEMPTION_ID, sy-vline,
WA_SATC_WL_FND_DV-PRIORITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SATC_WL_FND_DV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SATC_WL_FND_DV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SATC_WL_FND_DV INTO WA_SATC_WL_FND_DV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SATC_WL_FND_DV_STR,
WORKLIST_ID TYPE STRING,
OBJ_NAME TYPE STRING,
OBJ_TYPE TYPE STRING,
MODULE_ID TYPE STRING,
MODULE_MSG_KEY TYPE STRING,
CHECKSUM TYPE STRING,
CHANGED_ON TYPE STRING,
PROCESSOR TYPE STRING,
HAS_QUICKFIXES TYPE STRING,
EXEMPTION_ID TYPE STRING,
PRIORITY TYPE STRING,
EXC_KIND TYPE STRING,
EXC_VALIDITY TYPE STRING,
EXC_APPROVAL TYPE STRING,
ITEM_ID TYPE STRING,
CHECK_RUN_IX TYPE STRING,
LAST_CHANGED_BY TYPE STRING,
LAST_CHANGED_ON TYPE STRING,
CONTACT_PERSON TYPE STRING,
PACKAGE_NAME TYPE STRING,
DELETED TYPE STRING,
NAVIGATION_DATA TYPE STRING,
DESCRIPTION_DATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_SATC_WL_FND_DV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SATC_WL_FND_DV_STR-WORKLIST_ID sy-vline
WA_SATC_WL_FND_DV_STR-OBJ_NAME sy-vline
WA_SATC_WL_FND_DV_STR-OBJ_TYPE sy-vline
WA_SATC_WL_FND_DV_STR-MODULE_ID sy-vline
WA_SATC_WL_FND_DV_STR-MODULE_MSG_KEY sy-vline
WA_SATC_WL_FND_DV_STR-CHECKSUM sy-vline
WA_SATC_WL_FND_DV_STR-CHANGED_ON sy-vline
WA_SATC_WL_FND_DV_STR-PROCESSOR sy-vline
WA_SATC_WL_FND_DV_STR-HAS_QUICKFIXES sy-vline
WA_SATC_WL_FND_DV_STR-EXEMPTION_ID sy-vline
WA_SATC_WL_FND_DV_STR-PRIORITY sy-vline
WA_SATC_WL_FND_DV_STR-EXC_KIND sy-vline
WA_SATC_WL_FND_DV_STR-EXC_VALIDITY sy-vline
WA_SATC_WL_FND_DV_STR-EXC_APPROVAL sy-vline
WA_SATC_WL_FND_DV_STR-ITEM_ID sy-vline
WA_SATC_WL_FND_DV_STR-CHECK_RUN_IX sy-vline
WA_SATC_WL_FND_DV_STR-LAST_CHANGED_BY sy-vline
WA_SATC_WL_FND_DV_STR-LAST_CHANGED_ON sy-vline
WA_SATC_WL_FND_DV_STR-CONTACT_PERSON sy-vline
WA_SATC_WL_FND_DV_STR-PACKAGE_NAME sy-vline
WA_SATC_WL_FND_DV_STR-DELETED sy-vline
WA_SATC_WL_FND_DV_STR-NAVIGATION_DATA sy-vline
WA_SATC_WL_FND_DV_STR-DESCRIPTION_DATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.