ABAP Select data from SAP table SCIF_S4_WOC_CAPX into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SCIF_S4_WOC_CAPX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SCIF_S4_WOC_CAPX. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SCIF_S4_WOC_CAPX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SCIF_S4_WOC_CAPX TYPE STANDARD TABLE OF SCIF_S4_WOC_CAPX, WA_SCIF_S4_WOC_CAPX TYPE SCIF_S4_WOC_CAPX, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SCIF_S4_WOC_CAPX> TYPE SCIF_S4_WOC_CAPX. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SCIF_S4_WOC_CAPX. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SCIF_S4_WOC_CAPX INTO TABLE IT_SCIF_S4_WOC_CAPX. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SCIF_S4_WOC_CAPX * INTO TABLE @DATA(IT_SCIF_S4_WOC_CAPX2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SCIF_S4_WOC_CAPX INDEX 1 INTO DATA(WA_SCIF_S4_WOC_CAPX2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SCIF_S4_WOC_CAPX ASSIGNING <SCIF_S4_WOC_CAPX>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SCIF_S4_WOC_CAPX>-METHOD = 1.
<SCIF_S4_WOC_CAPX>-WERKS = 1.
<SCIF_S4_WOC_CAPX>-ARBPL = 1.
<SCIF_S4_WOC_CAPX>-KAPART = 1.
<SCIF_S4_WOC_CAPX>-FORK1 = 1.
ENDLOOP. LOOP AT IT_SCIF_S4_WOC_CAPX INTO WA_SCIF_S4_WOC_CAPX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SCIF_S4_WOC_CAPX-FORK2, sy-vline,
WA_SCIF_S4_WOC_CAPX-FORK3, sy-vline,
WA_SCIF_S4_WOC_CAPX-FORKN, sy-vline,
WA_SCIF_S4_WOC_CAPX-PLANR, sy-vline,
WA_SCIF_S4_WOC_CAPX-MOSID, sy-vline,
WA_SCIF_S4_WOC_CAPX-KALID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SCIF_S4_WOC_CAPX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SCIF_S4_WOC_CAPX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SCIF_S4_WOC_CAPX INTO WA_SCIF_S4_WOC_CAPX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SCIF_S4_WOC_CAPX_STR,
METHOD TYPE STRING,
WERKS TYPE STRING,
ARBPL TYPE STRING,
KAPART TYPE STRING,
FORK1 TYPE STRING,
FORK2 TYPE STRING,
FORK3 TYPE STRING,
FORKN TYPE STRING,
PLANR TYPE STRING,
MOSID TYPE STRING,
KALID TYPE STRING,
VERSA TYPE STRING,
MEINS TYPE STRING,
BEGZT TYPE STRING,
ENDZT TYPE STRING,
PAUSE TYPE STRING,
NGRAD TYPE STRING,
AZNOR TYPE STRING,
KAPEH TYPE STRING,
KAPTER TYPE STRING,
KAPAVO TYPE STRING,
UEBERLAST TYPE STRING,
TYPE TYPE STRING,
RESTYPE TYPE STRING,
CAPACITY_A TYPE STRING,
CAPACITY_A_UNIT TYPE STRING,
NUM_OF_PERIODS TYPE STRING,
PERIOD TYPE STRING,
BUFFERTIME TYPE STRING,
BUFFERTIME_UNIT TYPE STRING,
IS_BOTTLENECK TYPE STRING,
UNDERLOAD TYPE STRING,
OVERLAP_BUCKETS TYPE STRING,
START_ON_GRID TYPE STRING,
MIN_OVERLAP TYPE STRING,
MIN_OVERLAP_UNIT TYPE STRING,
LOSS_FACTOR TYPE STRING,
SORT TYPE STRING,
SYNC_START TYPE STRING,
DEFINE_BUCKETS TYPE STRING,
LC_DAYS_MINUS TYPE STRING,
LC_DAYS_PLUS TYPE STRING,
UTIL_BUCKET TYPE STRING,
CAMPAIGN_PPDS TYPE STRING,
TSTREAM_EXTERNAL TYPE STRING,
FINITY_LEVEL TYPE STRING,
PP_DEF_BUCKETS TYPE STRING,
PP_BUCKET_SCHEMA TYPE STRING,
PP_BUCKET_FACT TYPE STRING,
MIX_PLAN_TYPE TYPE STRING,
ANG_UNIT TYPE STRING,
ANG_MIN TYPE STRING,
ANG_MAX TYPE STRING,
STORAGE_CAPABLE TYPE STRING,
DIM_STORAGE TYPE STRING,
STORAGE_UNIT TYPE STRING,
MIN_STORAGE TYPE STRING,
MAX_STORAGE TYPE STRING,
STORAGE_TO_ZERO TYPE STRING,END OF T_EKKO_STR. DATA: WA_SCIF_S4_WOC_CAPX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SCIF_S4_WOC_CAPX_STR-METHOD sy-vline
WA_SCIF_S4_WOC_CAPX_STR-WERKS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-ARBPL sy-vline
WA_SCIF_S4_WOC_CAPX_STR-KAPART sy-vline
WA_SCIF_S4_WOC_CAPX_STR-FORK1 sy-vline
WA_SCIF_S4_WOC_CAPX_STR-FORK2 sy-vline
WA_SCIF_S4_WOC_CAPX_STR-FORK3 sy-vline
WA_SCIF_S4_WOC_CAPX_STR-FORKN sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PLANR sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MOSID sy-vline
WA_SCIF_S4_WOC_CAPX_STR-KALID sy-vline
WA_SCIF_S4_WOC_CAPX_STR-VERSA sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MEINS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-BEGZT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-ENDZT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PAUSE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-NGRAD sy-vline
WA_SCIF_S4_WOC_CAPX_STR-AZNOR sy-vline
WA_SCIF_S4_WOC_CAPX_STR-KAPEH sy-vline
WA_SCIF_S4_WOC_CAPX_STR-KAPTER sy-vline
WA_SCIF_S4_WOC_CAPX_STR-KAPAVO sy-vline
WA_SCIF_S4_WOC_CAPX_STR-UEBERLAST sy-vline
WA_SCIF_S4_WOC_CAPX_STR-TYPE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-RESTYPE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-CAPACITY_A sy-vline
WA_SCIF_S4_WOC_CAPX_STR-CAPACITY_A_UNIT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-NUM_OF_PERIODS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PERIOD sy-vline
WA_SCIF_S4_WOC_CAPX_STR-BUFFERTIME sy-vline
WA_SCIF_S4_WOC_CAPX_STR-BUFFERTIME_UNIT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-IS_BOTTLENECK sy-vline
WA_SCIF_S4_WOC_CAPX_STR-UNDERLOAD sy-vline
WA_SCIF_S4_WOC_CAPX_STR-OVERLAP_BUCKETS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-START_ON_GRID sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MIN_OVERLAP sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MIN_OVERLAP_UNIT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-LOSS_FACTOR sy-vline
WA_SCIF_S4_WOC_CAPX_STR-SORT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-SYNC_START sy-vline
WA_SCIF_S4_WOC_CAPX_STR-DEFINE_BUCKETS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-LC_DAYS_MINUS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-LC_DAYS_PLUS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-UTIL_BUCKET sy-vline
WA_SCIF_S4_WOC_CAPX_STR-CAMPAIGN_PPDS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-TSTREAM_EXTERNAL sy-vline
WA_SCIF_S4_WOC_CAPX_STR-FINITY_LEVEL sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PP_DEF_BUCKETS sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PP_BUCKET_SCHEMA sy-vline
WA_SCIF_S4_WOC_CAPX_STR-PP_BUCKET_FACT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MIX_PLAN_TYPE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-ANG_UNIT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-ANG_MIN sy-vline
WA_SCIF_S4_WOC_CAPX_STR-ANG_MAX sy-vline
WA_SCIF_S4_WOC_CAPX_STR-STORAGE_CAPABLE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-DIM_STORAGE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-STORAGE_UNIT sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MIN_STORAGE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-MAX_STORAGE sy-vline
WA_SCIF_S4_WOC_CAPX_STR-STORAGE_TO_ZERO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.