ABAP Select data from SAP table SDM_PROC_HISTORY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SDM_PROC_HISTORY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SDM_PROC_HISTORY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SDM_PROC_HISTORY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SDM_PROC_HISTORY TYPE STANDARD TABLE OF SDM_PROC_HISTORY,
      WA_SDM_PROC_HISTORY TYPE SDM_PROC_HISTORY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SDM_PROC_HISTORY> TYPE SDM_PROC_HISTORY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SDM_PROC_HISTORY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SDM_PROC_HISTORY
  INTO TABLE IT_SDM_PROC_HISTORY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SDM_PROC_HISTORY
*  INTO TABLE @DATA(IT_SDM_PROC_HISTORY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SDM_PROC_HISTORY INDEX 1 INTO DATA(WA_SDM_PROC_HISTORY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SDM_PROC_HISTORY ASSIGNING <SDM_PROC_HISTORY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SDM_PROC_HISTORY>-CLIENT = 1.
<SDM_PROC_HISTORY>-MIGRATION_CLASS = 1.
<SDM_PROC_HISTORY>-SUM_PHASE = 1.
<SDM_PROC_HISTORY>-TIMESTAMP = 1.
<SDM_PROC_HISTORY>-NUMBER_ROWS_NOT_DONE = 1.
ENDLOOP.

LOOP AT IT_SDM_PROC_HISTORY INTO WA_SDM_PROC_HISTORY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SDM_PROC_HISTORY-NUM_ACTIVE_PROCESSES, sy-vline,
WA_SDM_PROC_HISTORY-MIGRATION_STATUS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_SDM_PROC_HISTORY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SDM_PROC_HISTORY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SDM_PROC_HISTORY INTO WA_SDM_PROC_HISTORY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SDM_PROC_HISTORY_STR,
CLIENT TYPE STRING,
MIGRATION_CLASS TYPE STRING,
SUM_PHASE TYPE STRING,
TIMESTAMP TYPE STRING,
NUMBER_ROWS_NOT_DONE TYPE STRING,
NUM_ACTIVE_PROCESSES TYPE STRING,
MIGRATION_STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_SDM_PROC_HISTORY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SDM_PROC_HISTORY_STR-CLIENT sy-vline
WA_SDM_PROC_HISTORY_STR-MIGRATION_CLASS sy-vline
WA_SDM_PROC_HISTORY_STR-SUM_PHASE sy-vline
WA_SDM_PROC_HISTORY_STR-TIMESTAMP sy-vline
WA_SDM_PROC_HISTORY_STR-NUMBER_ROWS_NOT_DONE sy-vline
WA_SDM_PROC_HISTORY_STR-NUM_ACTIVE_PROCESSES sy-vline
WA_SDM_PROC_HISTORY_STR-MIGRATION_STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.