ABAP Select data from SAP table SHP_SE_FEH_OUTBDEL_COCNC_RQ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SHP_SE_FEH_OUTBDEL_COCNC_RQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SHP_SE_FEH_OUTBDEL_COCNC_RQ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SHP_SE_FEH_OUTBDEL_COCNC_RQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ TYPE STANDARD TABLE OF SHP_SE_FEH_OUTBDEL_COCNC_RQ, WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ TYPE SHP_SE_FEH_OUTBDEL_COCNC_RQ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SHP_SE_FEH_OUTBDEL_COCNC_RQ> TYPE SHP_SE_FEH_OUTBDEL_COCNC_RQ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SHP_SE_FEH_OUTBDEL_COCNC_RQ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SHP_SE_FEH_OUTBDEL_COCNC_RQ INTO TABLE IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SHP_SE_FEH_OUTBDEL_COCNC_RQ * INTO TABLE @DATA(IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ INDEX 1 INTO DATA(WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ ASSIGNING <SHP_SE_FEH_OUTBDEL_COCNC_RQ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SHP_SE_FEH_OUTBDEL_COCNC_RQ>-REQUEST_ID = 1.
<SHP_SE_FEH_OUTBDEL_COCNC_RQ>-HEADER = 1.
<SHP_SE_FEH_OUTBDEL_COCNC_RQ>-DELIV_NUMB = 1.
<SHP_SE_FEH_OUTBDEL_COCNC_RQ>-GROSS_WT = 1.
<SHP_SE_FEH_OUTBDEL_COCNC_RQ>-NET_WEIGHT = 1.
ENDLOOP. LOOP AT IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ INTO WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-UNIT_OF_WT, sy-vline,
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-UNIT_OF_WT_ISO, sy-vline,
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-VOLUME, sy-vline,
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-VOLUMEUNIT, sy-vline,
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-VOLUMEUNIT_ISO, sy-vline,
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DOOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SHP_SE_FEH_OUTBDEL_COCNC_RQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SHP_SE_FEH_OUTBDEL_COCNC_RQ INTO WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIVERY_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIVERY_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ-DELIVERY_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR,
REQUEST_ID TYPE STRING,
HEADER TYPE STRING,
DELIV_NUMB TYPE STRING,
GROSS_WT TYPE STRING,
NET_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
DOOR TYPE STRING,
INCOTERMS1 TYPE STRING,
INCOTERMS2 TYPE STRING,
ROUTE TYPE STRING,
SHIP_COND TYPE STRING,
DLV_PRIO TYPE STRING,
UNLOAD_PT TYPE STRING,
DLV_BLOCK TYPE STRING,
INCOTERMSV TYPE STRING,
INCOTERMS2L TYPE STRING,
INCOTERMS3L TYPE STRING,
HEADER_CTRL TYPE STRING,
DELIV_NUMB TYPE STRING,
GROSS_WT_FLG TYPE STRING,
NET_WT_FLG TYPE STRING,
VOLUME_FLG TYPE STRING,
DELIV_DATE_FLG TYPE STRING,
DOCK_FLG TYPE STRING,
DLV_DEL TYPE STRING,
INCO1_FLG TYPE STRING,
INCO2_FLG TYPE STRING,
ROUTE_FLG TYPE STRING,
SHIP_COND_FLG TYPE STRING,
DLV_PRIO_FLG TYPE STRING,
UNLOAD_PT_FLG TYPE STRING,
PICK_DATE_FLG TYPE STRING,
TRSP_DATE_FLG TYPE STRING,
LOAD_DATE_FLG TYPE STRING,
GDSI_DATE_FLG TYPE STRING,
SIMULATE TYPE STRING,
NO_LOCK TYPE STRING,
SPLIT_DONE_FLG TYPE STRING,
DLV_BLOCK_FLG TYPE STRING,
DLV_CHANGE_OFF TYPE STRING,
INCOV_FLG TYPE STRING,
INCO2_L_FLG TYPE STRING,
INCO3_L_FLG TYPE STRING,
HEADER_CTRL_SPL TYPE STRING,
SENDER_METHOD TYPE STRING,
DELIV_NUMB TYPE STRING,
GEOROUTE_FLG TYPE STRING,
BOP_GUID TYPE STRING,
INITIATOR_PROCESS TYPE STRING,
DELIVERY_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-REQUEST_ID sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-HEADER sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DELIV_NUMB sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-GROSS_WT sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-NET_WEIGHT sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-UNIT_OF_WT sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-UNIT_OF_WT_ISO sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-VOLUME sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-VOLUMEUNIT sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-VOLUMEUNIT_ISO sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DOOR sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOTERMS1 sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOTERMS2 sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-ROUTE sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-SHIP_COND sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_PRIO sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-UNLOAD_PT sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_BLOCK sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOTERMSV sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOTERMS2L sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOTERMS3L sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-HEADER_CTRL sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DELIV_NUMB sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-GROSS_WT_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-NET_WT_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-VOLUME_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DELIV_DATE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DOCK_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_DEL sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCO1_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCO2_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-ROUTE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-SHIP_COND_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_PRIO_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-UNLOAD_PT_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-PICK_DATE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-TRSP_DATE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-LOAD_DATE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-GDSI_DATE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-SIMULATE sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-NO_LOCK sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-SPLIT_DONE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_BLOCK_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DLV_CHANGE_OFF sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCOV_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCO2_L_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INCO3_L_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-HEADER_CTRL_SPL sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-SENDER_METHOD sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DELIV_NUMB sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-GEOROUTE_FLG sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-BOP_GUID sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-INITIATOR_PROCESS sy-vline
WA_SHP_SE_FEH_OUTBDEL_COCNC_RQ_STR-DELIVERY_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.