ABAP Select data from SAP table SHSMVMVLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SHSMVMVLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SHSMVMVLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SHSMVMVLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SHSMVMVLD TYPE STANDARD TABLE OF SHSMVMVLD,
      WA_SHSMVMVLD TYPE SHSMVMVLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SHSMVMVLD> TYPE SHSMVMVLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SHSMVMVLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SHSMVMVLD
  INTO TABLE IT_SHSMVMVLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SHSMVMVLD
*  INTO TABLE @DATA(IT_SHSMVMVLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SHSMVMVLD INDEX 1 INTO DATA(WA_SHSMVMVLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SHSMVMVLD ASSIGNING <SHSMVMVLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SHSMVMVLD>-MANDT = 1.
<SHSMVMVLD>-VBELN = 1.
<SHSMVMVLD>-KKBER = 1.
<SHSMVMVLD>-CMGST = 1.
<SHSMVMVLD>-SBGRP = 1.
ENDLOOP.

LOOP AT IT_SHSMVMVLD INTO WA_SHSMVMVLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SHSMVMVLD-CMNGV, sy-vline,
WA_SHSMVMVLD-KNKLI, sy-vline,
WA_SHSMVMVLD-CTLPC, sy-vline,
WA_SHSMVMVLD-GRUPP, sy-vline,
WA_SHSMVMVLD-CMFRE, sy-vline,
WA_SHSMVMVLD-VSTEL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SHSMVMVLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SHSMVMVLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SHSMVMVLD INTO WA_SHSMVMVLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHSMVMVLD-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHSMVMVLD-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KNKLI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SHSMVMVLD-KNKLI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SHSMVMVLD-KNKLI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SHSMVMVLD_STR,
MANDT TYPE STRING,
VBELN TYPE STRING,
KKBER TYPE STRING,
CMGST TYPE STRING,
SBGRP TYPE STRING,
CMNGV TYPE STRING,
KNKLI TYPE STRING,
CTLPC TYPE STRING,
GRUPP TYPE STRING,
CMFRE TYPE STRING,
VSTEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_SHSMVMVLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SHSMVMVLD_STR-MANDT sy-vline
WA_SHSMVMVLD_STR-VBELN sy-vline
WA_SHSMVMVLD_STR-KKBER sy-vline
WA_SHSMVMVLD_STR-CMGST sy-vline
WA_SHSMVMVLD_STR-SBGRP sy-vline
WA_SHSMVMVLD_STR-CMNGV sy-vline
WA_SHSMVMVLD_STR-KNKLI sy-vline
WA_SHSMVMVLD_STR-CTLPC sy-vline
WA_SHSMVMVLD_STR-GRUPP sy-vline
WA_SHSMVMVLD_STR-CMFRE sy-vline
WA_SHSMVMVLD_STR-VSTEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.