ABAP Select data from SAP table SLEI_BINDING into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SLEI_BINDING table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SLEI_BINDING. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SLEI_BINDING table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SLEI_BINDING TYPE STANDARD TABLE OF SLEI_BINDING, WA_SLEI_BINDING TYPE SLEI_BINDING, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SLEI_BINDING> TYPE SLEI_BINDING. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SLEI_BINDING. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SLEI_BINDING INTO TABLE IT_SLEI_BINDING. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SLEI_BINDING * INTO TABLE @DATA(IT_SLEI_BINDING2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SLEI_BINDING INDEX 1 INTO DATA(WA_SLEI_BINDING2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SLEI_BINDING ASSIGNING <SLEI_BINDING>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SLEI_BINDING>-LNKG_ID = 1.
<SLEI_BINDING>-DATAFLOW = 1.
<SLEI_BINDING>-TAB_INDEX = 1.
<SLEI_BINDING>-SOURCEEXPR = 1.
<SLEI_BINDING>-SOURCETYPE = 1.
ENDLOOP. LOOP AT IT_SLEI_BINDING INTO WA_SLEI_BINDING. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SLEI_BINDING-TARGETEXPR, sy-vline,
WA_SLEI_BINDING-TARGETTYPE, sy-vline,
WA_SLEI_BINDING-OPERATION, sy-vline,
WA_SLEI_BINDING-OPCLASS, sy-vline,
WA_SLEI_BINDING-SKIPSNULL, sy-vline,
WA_SLEI_BINDING-SKIPSINIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SLEI_BINDING you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SLEI_BINDING TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SLEI_BINDING INTO WA_SLEI_BINDING. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SLEI_BINDING_STR,
LNKG_ID TYPE STRING,
DATAFLOW TYPE STRING,
TAB_INDEX TYPE STRING,
SOURCEEXPR TYPE STRING,
SOURCETYPE TYPE STRING,
TARGETEXPR TYPE STRING,
TARGETTYPE TYPE STRING,
OPERATION TYPE STRING,
OPCLASS TYPE STRING,
SKIPSNULL TYPE STRING,
SKIPSINIT TYPE STRING,
NOVERWRITE TYPE STRING,
SKIPERROR TYPE STRING,
MOVE_CORR TYPE STRING,
TRANSTYPE TYPE STRING,
TRANSBASE TYPE STRING,
TRANSEXT TYPE STRING,
TRANSCATID TYPE STRING,
TRANSASYNC TYPE STRING,
TRANSDIALG TYPE STRING,
TRANSLOG TYPE STRING,
TRANSDEBUG TYPE STRING,END OF T_EKKO_STR. DATA: WA_SLEI_BINDING_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SLEI_BINDING_STR-LNKG_ID sy-vline
WA_SLEI_BINDING_STR-DATAFLOW sy-vline
WA_SLEI_BINDING_STR-TAB_INDEX sy-vline
WA_SLEI_BINDING_STR-SOURCEEXPR sy-vline
WA_SLEI_BINDING_STR-SOURCETYPE sy-vline
WA_SLEI_BINDING_STR-TARGETEXPR sy-vline
WA_SLEI_BINDING_STR-TARGETTYPE sy-vline
WA_SLEI_BINDING_STR-OPERATION sy-vline
WA_SLEI_BINDING_STR-OPCLASS sy-vline
WA_SLEI_BINDING_STR-SKIPSNULL sy-vline
WA_SLEI_BINDING_STR-SKIPSINIT sy-vline
WA_SLEI_BINDING_STR-NOVERWRITE sy-vline
WA_SLEI_BINDING_STR-SKIPERROR sy-vline
WA_SLEI_BINDING_STR-MOVE_CORR sy-vline
WA_SLEI_BINDING_STR-TRANSTYPE sy-vline
WA_SLEI_BINDING_STR-TRANSBASE sy-vline
WA_SLEI_BINDING_STR-TRANSEXT sy-vline
WA_SLEI_BINDING_STR-TRANSCATID sy-vline
WA_SLEI_BINDING_STR-TRANSASYNC sy-vline
WA_SLEI_BINDING_STR-TRANSDIALG sy-vline
WA_SLEI_BINDING_STR-TRANSLOG sy-vline
WA_SLEI_BINDING_STR-TRANSDEBUG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.