ABAP Select data from SAP table SLS_PRI_ST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SLS_PRI_ST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SLS_PRI_ST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SLS_PRI_ST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SLS_PRI_ST TYPE STANDARD TABLE OF SLS_PRI_ST,
      WA_SLS_PRI_ST TYPE SLS_PRI_ST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SLS_PRI_ST> TYPE SLS_PRI_ST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SLS_PRI_ST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SLS_PRI_ST
  INTO TABLE IT_SLS_PRI_ST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SLS_PRI_ST
*  INTO TABLE @DATA(IT_SLS_PRI_ST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SLS_PRI_ST INDEX 1 INTO DATA(WA_SLS_PRI_ST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SLS_PRI_ST ASSIGNING <SLS_PRI_ST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SLS_PRI_ST>-COUNTER = 1.
<SLS_PRI_ST>-PETID = 1.
<SLS_PRI_ST>-REFIRS = 1.
<SLS_PRI_ST>-RELAST = 1.
<SLS_PRI_ST>-PATYP = 1.
ENDLOOP.

LOOP AT IT_SLS_PRI_ST INTO WA_SLS_PRI_ST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SLS_PRI_ST-PARID, sy-vline,
WA_SLS_PRI_ST-PARTX, sy-vline,
WA_SLS_PRI_ST-ORGID, sy-vline,
WA_SLS_PRI_ST-ORGTX, sy-vline,
WA_SLS_PRI_ST-TESTID, sy-vline,
WA_SLS_PRI_ST-TNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SLS_PRI_ST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SLS_PRI_ST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SLS_PRI_ST INTO WA_SLS_PRI_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SLS_PRI_ST_STR,
COUNTER TYPE STRING,
PETID TYPE STRING,
REFIRS TYPE STRING,
RELAST TYPE STRING,
PATYP TYPE STRING,
PARID TYPE STRING,
PARTX TYPE STRING,
ORGID TYPE STRING,
ORGTX TYPE STRING,
TESTID TYPE STRING,
TNAME TYPE STRING,
DESCR TYPE STRING,
VAR4 TYPE STRING,
TDATE TYPE STRING,
DYNITEM TYPE STRING,
SCORING TYPE STRING,
ITEMTREAT TYPE STRING,
LOCID TYPE STRING,
LOCSH TYPE STRING,
LOCTX TYPE STRING,
EVID TYPE STRING,
NO_TEM TYPE STRING,
EVSHT TYPE STRING,
RPT TYPE STRING,
MAXPT TYPE STRING,
RPER TYPE STRING,
CUTOFF TYPE STRING,
PRINTED TYPE STRING,
PASS TYPE STRING,
ICON TYPE STRING,
TTYSH TYPE STRING,
CERTTYPE TYPE STRING,
CERTNAME TYPE STRING,
PRINTDATE TYPE STRING,
PRINTTIME TYPE STRING,
PRINTUSER TYPE STRING,END OF T_EKKO_STR. DATA: WA_SLS_PRI_ST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SLS_PRI_ST_STR-COUNTER sy-vline
WA_SLS_PRI_ST_STR-PETID sy-vline
WA_SLS_PRI_ST_STR-REFIRS sy-vline
WA_SLS_PRI_ST_STR-RELAST sy-vline
WA_SLS_PRI_ST_STR-PATYP sy-vline
WA_SLS_PRI_ST_STR-PARID sy-vline
WA_SLS_PRI_ST_STR-PARTX sy-vline
WA_SLS_PRI_ST_STR-ORGID sy-vline
WA_SLS_PRI_ST_STR-ORGTX sy-vline
WA_SLS_PRI_ST_STR-TESTID sy-vline
WA_SLS_PRI_ST_STR-TNAME sy-vline
WA_SLS_PRI_ST_STR-DESCR sy-vline
WA_SLS_PRI_ST_STR-VAR4 sy-vline
WA_SLS_PRI_ST_STR-TDATE sy-vline
WA_SLS_PRI_ST_STR-DYNITEM sy-vline
WA_SLS_PRI_ST_STR-SCORING sy-vline
WA_SLS_PRI_ST_STR-ITEMTREAT sy-vline
WA_SLS_PRI_ST_STR-LOCID sy-vline
WA_SLS_PRI_ST_STR-LOCSH sy-vline
WA_SLS_PRI_ST_STR-LOCTX sy-vline
WA_SLS_PRI_ST_STR-EVID sy-vline
WA_SLS_PRI_ST_STR-NO_TEM sy-vline
WA_SLS_PRI_ST_STR-EVSHT sy-vline
WA_SLS_PRI_ST_STR-RPT sy-vline
WA_SLS_PRI_ST_STR-MAXPT sy-vline
WA_SLS_PRI_ST_STR-RPER sy-vline
WA_SLS_PRI_ST_STR-CUTOFF sy-vline
WA_SLS_PRI_ST_STR-PRINTED sy-vline
WA_SLS_PRI_ST_STR-PASS sy-vline
WA_SLS_PRI_ST_STR-ICON sy-vline
WA_SLS_PRI_ST_STR-TTYSH sy-vline
WA_SLS_PRI_ST_STR-CERTTYPE sy-vline
WA_SLS_PRI_ST_STR-CERTNAME sy-vline
WA_SLS_PRI_ST_STR-PRINTDATE sy-vline
WA_SLS_PRI_ST_STR-PRINTTIME sy-vline
WA_SLS_PRI_ST_STR-PRINTUSER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.