ABAP Select data from SAP table SOS28 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SOS28 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SOS28. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SOS28 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SOS28 TYPE STANDARD TABLE OF SOS28,
      WA_SOS28 TYPE SOS28,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SOS28> TYPE SOS28.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SOS28.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SOS28
  INTO TABLE IT_SOS28.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SOS28
*  INTO TABLE @DATA(IT_SOS282).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SOS28 INDEX 1 INTO DATA(WA_SOS282).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SOS28 ASSIGNING <SOS28>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SOS28>-COUNTER = 1.
<SOS28>-REC_TYPDES = 1.
<SOS28>-REC_TYPE = 1.
<SOS28>-REC_CADR = 1.
<SOS28>-SND_TYPDES = 1.
ENDLOOP.

LOOP AT IT_SOS28 INTO WA_SOS28.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SOS28-SND_TYPE, sy-vline,
WA_SOS28-SND_CADR, sy-vline,
WA_SOS28-RES_CADR, sy-vline,
WA_SOS28-RES_TYPDES, sy-vline,
WA_SOS28-RESULT_TYP, sy-vline,
WA_SOS28-RESULT_ADR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SOS28 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SOS28 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SOS28 INTO WA_SOS28. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SXIDN, internal->external for field REC_CADR CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_SOS28-REC_CADR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SOS28-REC_CADR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field SND_CADR CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_SOS28-SND_CADR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SOS28-SND_CADR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field RES_CADR CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_SOS28-RES_CADR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SOS28-RES_CADR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RESULT_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_SOS28-RESULT_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_SOS28-RESULT_SYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SOS28_STR,
COUNTER TYPE STRING,
REC_TYPDES TYPE STRING,
REC_TYPE TYPE STRING,
REC_CADR TYPE STRING,
SND_TYPDES TYPE STRING,
SND_TYPE TYPE STRING,
SND_CADR TYPE STRING,
RES_CADR TYPE STRING,
RES_TYPDES TYPE STRING,
RESULT_TYP TYPE STRING,
RESULT_ADR TYPE STRING,
RESULT_SYS TYPE STRING,
RESULT_CLT TYPE STRING,
DOCTYPE TYPE STRING,
ADDITIONAL TYPE STRING,
ADD_TEXT TYPE STRING,
GENERIC TYPE STRING,
DEFAULT TYPE STRING,
DEF_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_SOS28_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SOS28_STR-COUNTER sy-vline
WA_SOS28_STR-REC_TYPDES sy-vline
WA_SOS28_STR-REC_TYPE sy-vline
WA_SOS28_STR-REC_CADR sy-vline
WA_SOS28_STR-SND_TYPDES sy-vline
WA_SOS28_STR-SND_TYPE sy-vline
WA_SOS28_STR-SND_CADR sy-vline
WA_SOS28_STR-RES_CADR sy-vline
WA_SOS28_STR-RES_TYPDES sy-vline
WA_SOS28_STR-RESULT_TYP sy-vline
WA_SOS28_STR-RESULT_ADR sy-vline
WA_SOS28_STR-RESULT_SYS sy-vline
WA_SOS28_STR-RESULT_CLT sy-vline
WA_SOS28_STR-DOCTYPE sy-vline
WA_SOS28_STR-ADDITIONAL sy-vline
WA_SOS28_STR-ADD_TEXT sy-vline
WA_SOS28_STR-GENERIC sy-vline
WA_SOS28_STR-DEFAULT sy-vline
WA_SOS28_STR-DEF_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.