ABAP Select data from SAP table SOST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SOST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SOST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SOST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SOST TYPE STANDARD TABLE OF SOST, WA_SOST TYPE SOST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SOST> TYPE SOST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SOST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SOST INTO TABLE IT_SOST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SOST * INTO TABLE @DATA(IT_SOST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SOST INDEX 1 INTO DATA(WA_SOST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SOST ASSIGNING <SOST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SOST>-MANDT = 1.
<SOST>-OBJTP = 1.
<SOST>-OBJYR = 1.
<SOST>-OBJNO = 1.
<SOST>-FORTP = 1.
ENDLOOP. LOOP AT IT_SOST INTO WA_SOST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SOST-FORYR, sy-vline,
WA_SOST-FORNO, sy-vline,
WA_SOST-RECTP, sy-vline,
WA_SOST-RECYR, sy-vline,
WA_SOST-RECNO, sy-vline,
WA_SOST-COUNTER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SOST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SOST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SOST INTO WA_SOST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SOST_STR,
MANDT TYPE STRING,
OBJTP TYPE STRING,
OBJYR TYPE STRING,
OBJNO TYPE STRING,
FORTP TYPE STRING,
FORYR TYPE STRING,
FORNO TYPE STRING,
RECTP TYPE STRING,
RECYR TYPE STRING,
RECNO TYPE STRING,
COUNTER TYPE STRING,
SNDART TYPE STRING,
SCOMTP TYPE STRING,
SCOMYR TYPE STRING,
SCOMNO TYPE STRING,
ENTRY_DATE TYPE STRING,
ENTRY_TIME TYPE STRING,
STAT_DATE TYPE STRING,
STAT_TIME TYPE STRING,
MSGID TYPE STRING,
MSGTY TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
CREATOR TYPE STRING,
SENDER TYPE STRING,
DIRECTION TYPE STRING,
STA_ORDER TYPE STRING,END OF T_EKKO_STR. DATA: WA_SOST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SOST_STR-MANDT sy-vline
WA_SOST_STR-OBJTP sy-vline
WA_SOST_STR-OBJYR sy-vline
WA_SOST_STR-OBJNO sy-vline
WA_SOST_STR-FORTP sy-vline
WA_SOST_STR-FORYR sy-vline
WA_SOST_STR-FORNO sy-vline
WA_SOST_STR-RECTP sy-vline
WA_SOST_STR-RECYR sy-vline
WA_SOST_STR-RECNO sy-vline
WA_SOST_STR-COUNTER sy-vline
WA_SOST_STR-SNDART sy-vline
WA_SOST_STR-SCOMTP sy-vline
WA_SOST_STR-SCOMYR sy-vline
WA_SOST_STR-SCOMNO sy-vline
WA_SOST_STR-ENTRY_DATE sy-vline
WA_SOST_STR-ENTRY_TIME sy-vline
WA_SOST_STR-STAT_DATE sy-vline
WA_SOST_STR-STAT_TIME sy-vline
WA_SOST_STR-MSGID sy-vline
WA_SOST_STR-MSGTY sy-vline
WA_SOST_STR-MSGNO sy-vline
WA_SOST_STR-MSGV1 sy-vline
WA_SOST_STR-MSGV2 sy-vline
WA_SOST_STR-MSGV3 sy-vline
WA_SOST_STR-MSGV4 sy-vline
WA_SOST_STR-CREATOR sy-vline
WA_SOST_STR-SENDER sy-vline
WA_SOST_STR-DIRECTION sy-vline
WA_SOST_STR-STA_ORDER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.