ABAP Select data from SAP table SOSUO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SOSUO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SOSUO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SOSUO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SOSUO TYPE STANDARD TABLE OF SOSUO,
      WA_SOSUO TYPE SOSUO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SOSUO> TYPE SOSUO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SOSUO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SOSUO
  INTO TABLE IT_SOSUO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SOSUO
*  INTO TABLE @DATA(IT_SOSUO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SOSUO INDEX 1 INTO DATA(WA_SOSUO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SOSUO ASSIGNING <SOSUO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SOSUO>-USRTP = 1.
<SOSUO>-USRYR = 1.
<SOSUO>-USRNO = 1.
<SOSUO>-SUBTP = 1.
<SOSUO>-SUBYR = 1.
ENDLOOP.

LOOP AT IT_SOSUO INTO WA_SOSUO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SOSUO-SUBNO, sy-vline,
WA_SOSUO-SUCNT, sy-vline,
WA_SOSUO-SBDAT, sy-vline,
WA_SOSUO-SBTIM, sy-vline,
WA_SOSUO-SEDAT, sy-vline,
WA_SOSUO-SETIM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SOSUO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SOSUO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SOSUO INTO WA_SOSUO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SOSUO_STR,
USRTP TYPE STRING,
USRYR TYPE STRING,
USRNO TYPE STRING,
SUBTP TYPE STRING,
SUBYR TYPE STRING,
SUBNO TYPE STRING,
SUCNT TYPE STRING,
SBDAT TYPE STRING,
SBTIM TYPE STRING,
SEDAT TYPE STRING,
SETIM TYPE STRING,
PSTHR1 TYPE STRING,
PSTHR2 TYPE STRING,
AUTINT TYPE STRING,
AUTEXT TYPE STRING,
AUSER TYPE STRING,
PUBDL TYPE STRING,
BCOPY TYPE STRING,
OBJAPR TYPE STRING,
OBJACO TYPE STRING,
OBJACC TYPE STRING,
OBJAFC TYPE STRING,
AUANS TYPE STRING,
RESUB TYPE STRING,
AUSSL TYPE STRING,
PUFOL TYPE STRING,
PROTI TYPE STRING,
PROTO TYPE STRING,
PROT1 TYPE STRING,
PROT2 TYPE STRING,
PROT3 TYPE STRING,
PROT4 TYPE STRING,
PROT5 TYPE STRING,
PROT6 TYPE STRING,
PROT7 TYPE STRING,
PROT8 TYPE STRING,
PROT9 TYPE STRING,
OBJTP1 TYPE STRING,
OBJYR1 TYPE STRING,
OBJNO1 TYPE STRING,
OBJTP2 TYPE STRING,
OBJYR2 TYPE STRING,
OBJNO2 TYPE STRING,
OBJTP3 TYPE STRING,
OBJYR3 TYPE STRING,
OBJNO3 TYPE STRING,
FLAG0 TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
FLAG5 TYPE STRING,
FLAG6 TYPE STRING,
FLAG7 TYPE STRING,
FLAG8 TYPE STRING,
FLAG9 TYPE STRING,
AUTFW TYPE STRING,
AUTFW1 TYPE STRING,
COMART TYPE STRING,
LFDNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_SOSUO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SOSUO_STR-USRTP sy-vline
WA_SOSUO_STR-USRYR sy-vline
WA_SOSUO_STR-USRNO sy-vline
WA_SOSUO_STR-SUBTP sy-vline
WA_SOSUO_STR-SUBYR sy-vline
WA_SOSUO_STR-SUBNO sy-vline
WA_SOSUO_STR-SUCNT sy-vline
WA_SOSUO_STR-SBDAT sy-vline
WA_SOSUO_STR-SBTIM sy-vline
WA_SOSUO_STR-SEDAT sy-vline
WA_SOSUO_STR-SETIM sy-vline
WA_SOSUO_STR-PSTHR1 sy-vline
WA_SOSUO_STR-PSTHR2 sy-vline
WA_SOSUO_STR-AUTINT sy-vline
WA_SOSUO_STR-AUTEXT sy-vline
WA_SOSUO_STR-AUSER sy-vline
WA_SOSUO_STR-PUBDL sy-vline
WA_SOSUO_STR-BCOPY sy-vline
WA_SOSUO_STR-OBJAPR sy-vline
WA_SOSUO_STR-OBJACO sy-vline
WA_SOSUO_STR-OBJACC sy-vline
WA_SOSUO_STR-OBJAFC sy-vline
WA_SOSUO_STR-AUANS sy-vline
WA_SOSUO_STR-RESUB sy-vline
WA_SOSUO_STR-AUSSL sy-vline
WA_SOSUO_STR-PUFOL sy-vline
WA_SOSUO_STR-PROTI sy-vline
WA_SOSUO_STR-PROTO sy-vline
WA_SOSUO_STR-PROT1 sy-vline
WA_SOSUO_STR-PROT2 sy-vline
WA_SOSUO_STR-PROT3 sy-vline
WA_SOSUO_STR-PROT4 sy-vline
WA_SOSUO_STR-PROT5 sy-vline
WA_SOSUO_STR-PROT6 sy-vline
WA_SOSUO_STR-PROT7 sy-vline
WA_SOSUO_STR-PROT8 sy-vline
WA_SOSUO_STR-PROT9 sy-vline
WA_SOSUO_STR-OBJTP1 sy-vline
WA_SOSUO_STR-OBJYR1 sy-vline
WA_SOSUO_STR-OBJNO1 sy-vline
WA_SOSUO_STR-OBJTP2 sy-vline
WA_SOSUO_STR-OBJYR2 sy-vline
WA_SOSUO_STR-OBJNO2 sy-vline
WA_SOSUO_STR-OBJTP3 sy-vline
WA_SOSUO_STR-OBJYR3 sy-vline
WA_SOSUO_STR-OBJNO3 sy-vline
WA_SOSUO_STR-FLAG0 sy-vline
WA_SOSUO_STR-FLAG1 sy-vline
WA_SOSUO_STR-FLAG2 sy-vline
WA_SOSUO_STR-FLAG3 sy-vline
WA_SOSUO_STR-FLAG4 sy-vline
WA_SOSUO_STR-FLAG5 sy-vline
WA_SOSUO_STR-FLAG6 sy-vline
WA_SOSUO_STR-FLAG7 sy-vline
WA_SOSUO_STR-FLAG8 sy-vline
WA_SOSUO_STR-FLAG9 sy-vline
WA_SOSUO_STR-AUTFW sy-vline
WA_SOSUO_STR-AUTFW1 sy-vline
WA_SOSUO_STR-COMART sy-vline
WA_SOSUO_STR-LFDNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.