ABAP Select data from SAP table SPERFSTA_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SPERFSTA_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SPERFSTA_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SPERFSTA_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SPERFSTA_D TYPE STANDARD TABLE OF SPERFSTA_D,
      WA_SPERFSTA_D TYPE SPERFSTA_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SPERFSTA_D> TYPE SPERFSTA_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SPERFSTA_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SPERFSTA_D
  INTO TABLE IT_SPERFSTA_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SPERFSTA_D
*  INTO TABLE @DATA(IT_SPERFSTA_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SPERFSTA_D INDEX 1 INTO DATA(WA_SPERFSTA_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SPERFSTA_D ASSIGNING <SPERFSTA_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SPERFSTA_D>-STARTDATE = 1.
<SPERFSTA_D>-STARTTIME = 1.
<SPERFSTA_D>-ENDDATE = 1.
<SPERFSTA_D>-ENDTIME = 1.
<SPERFSTA_D>-TCODE = 1.
ENDLOOP.

LOOP AT IT_SPERFSTA_D INTO WA_SPERFSTA_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SPERFSTA_D-REPORT, sy-vline,
WA_SPERFSTA_D-TASKTYPE, sy-vline,
WA_SPERFSTA_D-DYNPRONR, sy-vline,
WA_SPERFSTA_D-WPROCTIME, sy-vline,
WA_SPERFSTA_D-KBYTETRANS, sy-vline,
WA_SPERFSTA_D-RESPTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SPERFSTA_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SPERFSTA_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SPERFSTA_D INTO WA_SPERFSTA_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SPERFSTA_D_STR,
STARTDATE TYPE STRING,
STARTTIME TYPE STRING,
ENDDATE TYPE STRING,
ENDTIME TYPE STRING,
TCODE TYPE STRING,
REPORT TYPE STRING,
TASKTYPE TYPE STRING,
DYNPRONR TYPE STRING,
WPROCTIME TYPE STRING,
KBYTETRANS TYPE STRING,
RESPTIME TYPE STRING,
WAITTIME TYPE STRING,
CPUTIME TYPE STRING,
LDGENTIME TYPE STRING,
MEMORYUSED TYPE STRING,
DBTIME TYPE STRING,
DBCHANGES TYPE STRING,
ROUNDTRIPS TYPE STRING,
INDATA TYPE STRING,
OUTDATA TYPE STRING,
RECPROCNUM_ST TYPE STRING,
TOTALEX_ST TYPE STRING,END OF T_EKKO_STR. DATA: WA_SPERFSTA_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SPERFSTA_D_STR-STARTDATE sy-vline
WA_SPERFSTA_D_STR-STARTTIME sy-vline
WA_SPERFSTA_D_STR-ENDDATE sy-vline
WA_SPERFSTA_D_STR-ENDTIME sy-vline
WA_SPERFSTA_D_STR-TCODE sy-vline
WA_SPERFSTA_D_STR-REPORT sy-vline
WA_SPERFSTA_D_STR-TASKTYPE sy-vline
WA_SPERFSTA_D_STR-DYNPRONR sy-vline
WA_SPERFSTA_D_STR-WPROCTIME sy-vline
WA_SPERFSTA_D_STR-KBYTETRANS sy-vline
WA_SPERFSTA_D_STR-RESPTIME sy-vline
WA_SPERFSTA_D_STR-WAITTIME sy-vline
WA_SPERFSTA_D_STR-CPUTIME sy-vline
WA_SPERFSTA_D_STR-LDGENTIME sy-vline
WA_SPERFSTA_D_STR-MEMORYUSED sy-vline
WA_SPERFSTA_D_STR-DBTIME sy-vline
WA_SPERFSTA_D_STR-DBCHANGES sy-vline
WA_SPERFSTA_D_STR-ROUNDTRIPS sy-vline
WA_SPERFSTA_D_STR-INDATA sy-vline
WA_SPERFSTA_D_STR-OUTDATA sy-vline
WA_SPERFSTA_D_STR-RECPROCNUM_ST sy-vline
WA_SPERFSTA_D_STR-TOTALEX_ST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.