ABAP Select data from SAP table SPRXT_MESSTYPE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP SPRXT_MESSTYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SPRXT_MESSTYPE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the SPRXT_MESSTYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_SPRXT_MESSTYPE TYPE STANDARD TABLE OF SPRXT_MESSTYPE, WA_SPRXT_MESSTYPE TYPE SPRXT_MESSTYPE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <SPRXT_MESSTYPE> TYPE SPRXT_MESSTYPE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_SPRXT_MESSTYPE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM SPRXT_MESSTYPE INTO TABLE IT_SPRXT_MESSTYPE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM SPRXT_MESSTYPE * INTO TABLE @DATA(IT_SPRXT_MESSTYPE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_SPRXT_MESSTYPE INDEX 1 INTO DATA(WA_SPRXT_MESSTYPE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_SPRXT_MESSTYPE ASSIGNING <SPRXT_MESSTYPE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<SPRXT_MESSTYPE>-CONTROLLER = 1.
<SPRXT_MESSTYPE>-MESSTYPE = 1.
<SPRXT_MESSTYPE>-CONTROLLER = 1.
<SPRXT_MESSTYPE>-FELD1 = 1.
<SPRXT_MESSTYPE>-CONTROLLER = 1.
ENDLOOP. LOOP AT IT_SPRXT_MESSTYPE INTO WA_SPRXT_MESSTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_SPRXT_MESSTYPE-FELDA1, sy-vline,
WA_SPRXT_MESSTYPE-FELDA2, sy-vline,
WA_SPRXT_MESSTYPE-FELDA3, sy-vline,
WA_SPRXT_MESSTYPE-CONTROLLER, sy-vline,
WA_SPRXT_MESSTYPE-CHOICE, sy-vline,
WA_SPRXT_MESSTYPE-SELECTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SPRXT_MESSTYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SPRXT_MESSTYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SPRXT_MESSTYPE INTO WA_SPRXT_MESSTYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SPRXT_MESSTYPE_STR,
CONTROLLER TYPE STRING,
MESSTYPE TYPE STRING,
CONTROLLER TYPE STRING,
FELD1 TYPE STRING,
CONTROLLER TYPE STRING,
FELDA1 TYPE STRING,
FELDA2 TYPE STRING,
FELDA3 TYPE STRING,
CONTROLLER TYPE STRING,
CHOICE TYPE STRING,
SELECTION TYPE STRING,
CONTROLLER TYPE STRING,
C1 TYPE STRING,
C2 TYPE STRING,
FELD2 TYPE STRING,
CONTROLLER TYPE STRING,
TEXT1 TYPE STRING,
CONTROLLER TYPE STRING,
TEXTATT TYPE STRING,
CONTENT TYPE STRING,
TEXT2 TYPE STRING,
CONTROLLER TYPE STRING,
TEXTATT TYPE STRING,
CONTENT TYPE STRING,
FELD2ATTR TYPE STRING,
FELD3 TYPE STRING,
FELD4 TYPE STRING,
CONTROLLER TYPE STRING,
FELDB1 TYPE STRING,
FELDB2 TYPE STRING,
GLOBAL_ATT TYPE STRING,END OF T_EKKO_STR. DATA: WA_SPRXT_MESSTYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-MESSTYPE sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-FELD1 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-FELDA1 sy-vline
WA_SPRXT_MESSTYPE_STR-FELDA2 sy-vline
WA_SPRXT_MESSTYPE_STR-FELDA3 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-CHOICE sy-vline
WA_SPRXT_MESSTYPE_STR-SELECTION sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-C1 sy-vline
WA_SPRXT_MESSTYPE_STR-C2 sy-vline
WA_SPRXT_MESSTYPE_STR-FELD2 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-TEXT1 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-TEXTATT sy-vline
WA_SPRXT_MESSTYPE_STR-CONTENT sy-vline
WA_SPRXT_MESSTYPE_STR-TEXT2 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-TEXTATT sy-vline
WA_SPRXT_MESSTYPE_STR-CONTENT sy-vline
WA_SPRXT_MESSTYPE_STR-FELD2ATTR sy-vline
WA_SPRXT_MESSTYPE_STR-FELD3 sy-vline
WA_SPRXT_MESSTYPE_STR-FELD4 sy-vline
WA_SPRXT_MESSTYPE_STR-CONTROLLER sy-vline
WA_SPRXT_MESSTYPE_STR-FELDB1 sy-vline
WA_SPRXT_MESSTYPE_STR-FELDB2 sy-vline
WA_SPRXT_MESSTYPE_STR-GLOBAL_ATT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.