ABAP Select data from SAP table SYCM_ATC_FND into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP SYCM_ATC_FND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to SYCM_ATC_FND. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the SYCM_ATC_FND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_SYCM_ATC_FND TYPE STANDARD TABLE OF SYCM_ATC_FND,
      WA_SYCM_ATC_FND TYPE SYCM_ATC_FND,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <SYCM_ATC_FND> TYPE SYCM_ATC_FND.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_SYCM_ATC_FND.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM SYCM_ATC_FND
  INTO TABLE IT_SYCM_ATC_FND.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM SYCM_ATC_FND
*  INTO TABLE @DATA(IT_SYCM_ATC_FND2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_SYCM_ATC_FND INDEX 1 INTO DATA(WA_SYCM_ATC_FND2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_SYCM_ATC_FND ASSIGNING <SYCM_ATC_FND>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<SYCM_ATC_FND>-ITEM_ID = 1.
<SYCM_ATC_FND>-DISPLAY_ID = 1.
<SYCM_ATC_FND>-OBJ_NAME = 1.
<SYCM_ATC_FND>-OBJ_TYPE = 1.
<SYCM_ATC_FND>-PACKAGE_NAME = 1.
ENDLOOP.

LOOP AT IT_SYCM_ATC_FND INTO WA_SYCM_ATC_FND.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_SYCM_ATC_FND-PRIORITY, sy-vline,
WA_SYCM_ATC_FND-HAS_QUICKFIXES, sy-vline,
WA_SYCM_ATC_FND-NOTE, sy-vline,
WA_SYCM_ATC_FND-REFERENCED_OBJECT_TYPE, sy-vline,
WA_SYCM_ATC_FND-REFERENCED_OBJECT_NAME, sy-vline,
WA_SYCM_ATC_FND-SIMPLIFICATION_ITEM_STATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_SYCM_ATC_FND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_SYCM_ATC_FND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_SYCM_ATC_FND INTO WA_SYCM_ATC_FND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_SYCM_ATC_FND_STR,
ITEM_ID TYPE STRING,
DISPLAY_ID TYPE STRING,
OBJ_NAME TYPE STRING,
OBJ_TYPE TYPE STRING,
PACKAGE_NAME TYPE STRING,
PRIORITY TYPE STRING,
HAS_QUICKFIXES TYPE STRING,
NOTE TYPE STRING,
REFERENCED_OBJECT_TYPE TYPE STRING,
REFERENCED_OBJECT_NAME TYPE STRING,
SIMPLIFICATION_ITEM_STATE TYPE STRING,
CHECK_CLASS TYPE STRING,
MESSAGE_CODE TYPE STRING,
USAGE_INFORMATION TYPE STRING,
SCOPE_INFORMATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_SYCM_ATC_FND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_SYCM_ATC_FND_STR-ITEM_ID sy-vline
WA_SYCM_ATC_FND_STR-DISPLAY_ID sy-vline
WA_SYCM_ATC_FND_STR-OBJ_NAME sy-vline
WA_SYCM_ATC_FND_STR-OBJ_TYPE sy-vline
WA_SYCM_ATC_FND_STR-PACKAGE_NAME sy-vline
WA_SYCM_ATC_FND_STR-PRIORITY sy-vline
WA_SYCM_ATC_FND_STR-HAS_QUICKFIXES sy-vline
WA_SYCM_ATC_FND_STR-NOTE sy-vline
WA_SYCM_ATC_FND_STR-REFERENCED_OBJECT_TYPE sy-vline
WA_SYCM_ATC_FND_STR-REFERENCED_OBJECT_NAME sy-vline
WA_SYCM_ATC_FND_STR-SIMPLIFICATION_ITEM_STATE sy-vline
WA_SYCM_ATC_FND_STR-CHECK_CLASS sy-vline
WA_SYCM_ATC_FND_STR-MESSAGE_CODE sy-vline
WA_SYCM_ATC_FND_STR-USAGE_INFORMATION sy-vline
WA_SYCM_ATC_FND_STR-SCOPE_INFORMATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.