ABAP Select data from SAP table T5FDSNRETAX into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T5FDSNRETAX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T5FDSNRETAX. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T5FDSNRETAX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T5FDSNRETAX TYPE STANDARD TABLE OF T5FDSNRETAX, WA_T5FDSNRETAX TYPE T5FDSNRETAX, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T5FDSNRETAX> TYPE T5FDSNRETAX. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T5FDSNRETAX. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T5FDSNRETAX INTO TABLE IT_T5FDSNRETAX. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T5FDSNRETAX * INTO TABLE @DATA(IT_T5FDSNRETAX2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T5FDSNRETAX INDEX 1 INTO DATA(WA_T5FDSNRETAX2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T5FDSNRETAX ASSIGNING <T5FDSNRETAX>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T5FDSNRETAX>-MANDT = 1.
<T5FDSNRETAX>-PERNR = 1.
<T5FDSNRETAX>-FPPER = 1.
<T5FDSNRETAX>-FPBEG = 1.
<T5FDSNRETAX>-FPEND = 1.
ENDLOOP. LOOP AT IT_T5FDSNRETAX INTO WA_T5FDSNRETAX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T5FDSNRETAX-INPER, sy-vline,
WA_T5FDSNRETAX-IPEND, sy-vline,
WA_T5FDSNRETAX-NUMTX, sy-vline,
WA_T5FDSNRETAX-NRCUM, sy-vline,
WA_T5FDSNRETAX-DSNZO, sy-vline,
WA_T5FDSNRETAX-CATEG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T5FDSNRETAX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T5FDSNRETAX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T5FDSNRETAX INTO WA_T5FDSNRETAX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T5FDSNRETAX_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
FPPER TYPE STRING,
FPBEG TYPE STRING,
FPEND TYPE STRING,
INPER TYPE STRING,
IPEND TYPE STRING,
NUMTX TYPE STRING,
NRCUM TYPE STRING,
DSNZO TYPE STRING,
CATEG TYPE STRING,
APZNR TYPE STRING,
CNTR1 TYPE STRING,
CNTR2 TYPE STRING,
SPLT1 TYPE STRING,
PASID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
UIDCT TYPE STRING,
CONUM TYPE STRING,
TYEAR TYPE STRING,
TPERI TYPE STRING,
DYEAR TYPE STRING,
STATS TYPE STRING,
SUBST TYPE STRING,
TAXWG TYPE STRING,
MODCD TYPE STRING,
TAXTY TYPE STRING,
TAXWT TYPE STRING,
VALUE TYPE STRING,
DELTA TYPE STRING,
WAERS TYPE STRING,
OPERA TYPE STRING,
PERCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_T5FDSNRETAX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T5FDSNRETAX_STR-MANDT sy-vline
WA_T5FDSNRETAX_STR-PERNR sy-vline
WA_T5FDSNRETAX_STR-FPPER sy-vline
WA_T5FDSNRETAX_STR-FPBEG sy-vline
WA_T5FDSNRETAX_STR-FPEND sy-vline
WA_T5FDSNRETAX_STR-INPER sy-vline
WA_T5FDSNRETAX_STR-IPEND sy-vline
WA_T5FDSNRETAX_STR-NUMTX sy-vline
WA_T5FDSNRETAX_STR-NRCUM sy-vline
WA_T5FDSNRETAX_STR-DSNZO sy-vline
WA_T5FDSNRETAX_STR-CATEG sy-vline
WA_T5FDSNRETAX_STR-APZNR sy-vline
WA_T5FDSNRETAX_STR-CNTR1 sy-vline
WA_T5FDSNRETAX_STR-CNTR2 sy-vline
WA_T5FDSNRETAX_STR-SPLT1 sy-vline
WA_T5FDSNRETAX_STR-PASID sy-vline
WA_T5FDSNRETAX_STR-BEGDA sy-vline
WA_T5FDSNRETAX_STR-ENDDA sy-vline
WA_T5FDSNRETAX_STR-UIDCT sy-vline
WA_T5FDSNRETAX_STR-CONUM sy-vline
WA_T5FDSNRETAX_STR-TYEAR sy-vline
WA_T5FDSNRETAX_STR-TPERI sy-vline
WA_T5FDSNRETAX_STR-DYEAR sy-vline
WA_T5FDSNRETAX_STR-STATS sy-vline
WA_T5FDSNRETAX_STR-SUBST sy-vline
WA_T5FDSNRETAX_STR-TAXWG sy-vline
WA_T5FDSNRETAX_STR-MODCD sy-vline
WA_T5FDSNRETAX_STR-TAXTY sy-vline
WA_T5FDSNRETAX_STR-TAXWT sy-vline
WA_T5FDSNRETAX_STR-VALUE sy-vline
WA_T5FDSNRETAX_STR-DELTA sy-vline
WA_T5FDSNRETAX_STR-WAERS sy-vline
WA_T5FDSNRETAX_STR-OPERA sy-vline
WA_T5FDSNRETAX_STR-PERCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.