ABAP Select data from SAP table T5FN4DS105 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T5FN4DS105 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T5FN4DS105. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T5FN4DS105 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T5FN4DS105 TYPE STANDARD TABLE OF T5FN4DS105, WA_T5FN4DS105 TYPE T5FN4DS105, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T5FN4DS105> TYPE T5FN4DS105. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T5FN4DS105. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T5FN4DS105 INTO TABLE IT_T5FN4DS105. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T5FN4DS105 * INTO TABLE @DATA(IT_T5FN4DS1052). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T5FN4DS105 INDEX 1 INTO DATA(WA_T5FN4DS1052). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T5FN4DS105 ASSIGNING <T5FN4DS105>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T5FN4DS105>-MANDT = 1.
<T5FN4DS105>-TYPE = 1.
<T5FN4DS105>-RUNID = 1.
<T5FN4DS105>-DECLNR = 1.
<T5FN4DS105>-PERNR = 1.
ENDLOOP. LOOP AT IT_T5FN4DS105 INTO WA_T5FN4DS105. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T5FN4DS105-SEQNR, sy-vline,
WA_T5FN4DS105-SIREN, sy-vline,
WA_T5FN4DS105-PTYPE, sy-vline,
WA_T5FN4DS105-ACBEG, sy-vline,
WA_T5FN4DS105-ACSRN, sy-vline,
WA_T5FN4DS105-ACEND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T5FN4DS105 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T5FN4DS105 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T5FN4DS105 INTO WA_T5FN4DS105. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T5FN4DS105_STR,
MANDT TYPE STRING,
TYPE TYPE STRING,
RUNID TYPE STRING,
DECLNR TYPE STRING,
PERNR TYPE STRING,
SEQNR TYPE STRING,
SIREN TYPE STRING,
PTYPE TYPE STRING,
ACBEG TYPE STRING,
ACSRN TYPE STRING,
ACEND TYPE STRING,
ACERN TYPE STRING,
ACNIC TYPE STRING,
IACON TYPE STRING,
IACDE TYPE STRING,
PCOPR TYPE STRING,
PCPOP TYPE STRING,END OF T_EKKO_STR. DATA: WA_T5FN4DS105_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T5FN4DS105_STR-MANDT sy-vline
WA_T5FN4DS105_STR-TYPE sy-vline
WA_T5FN4DS105_STR-RUNID sy-vline
WA_T5FN4DS105_STR-DECLNR sy-vline
WA_T5FN4DS105_STR-PERNR sy-vline
WA_T5FN4DS105_STR-SEQNR sy-vline
WA_T5FN4DS105_STR-SIREN sy-vline
WA_T5FN4DS105_STR-PTYPE sy-vline
WA_T5FN4DS105_STR-ACBEG sy-vline
WA_T5FN4DS105_STR-ACSRN sy-vline
WA_T5FN4DS105_STR-ACEND sy-vline
WA_T5FN4DS105_STR-ACERN sy-vline
WA_T5FN4DS105_STR-ACNIC sy-vline
WA_T5FN4DS105_STR-IACON sy-vline
WA_T5FN4DS105_STR-IACDE sy-vline
WA_T5FN4DS105_STR-PCOPR sy-vline
WA_T5FN4DS105_STR-PCPOP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.