ABAP Select data from SAP table T706B2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T706B2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T706B2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T706B2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T706B2 TYPE STANDARD TABLE OF T706B2,
      WA_T706B2 TYPE T706B2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T706B2> TYPE T706B2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T706B2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T706B2
  INTO TABLE IT_T706B2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T706B2
*  INTO TABLE @DATA(IT_T706B22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T706B2 INDEX 1 INTO DATA(WA_T706B22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T706B2 ASSIGNING <T706B2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T706B2>-MANDT = 1.
<T706B2>-MOREI = 1.
<T706B2>-KZREA = 1.
<T706B2>-BEREI = 1.
<T706B2>-KZTKT = 1.
ENDLOOP.

LOOP AT IT_T706B2 INTO WA_T706B2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T706B2-LNDGR, sy-vline,
WA_T706B2-RGION, sy-vline,
WA_T706B2-ERKLA, sy-vline,
WA_T706B2-ERGRU, sy-vline,
WA_T706B2-SPKZL, sy-vline,
WA_T706B2-ATYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T706B2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T706B2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T706B2 INTO WA_T706B2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T706B2_STR,
MANDT TYPE STRING,
MOREI TYPE STRING,
KZREA TYPE STRING,
BEREI TYPE STRING,
KZTKT TYPE STRING,
LNDGR TYPE STRING,
RGION TYPE STRING,
ERKLA TYPE STRING,
ERGRU TYPE STRING,
SPKZL TYPE STRING,
ATYPE TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
WAERS TYPE STRING,
BETRG TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
DVAT TYPE STRING,
MAXDIFF TYPE STRING,
MAXDIFF_CURR TYPE STRING,
PERC_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_T706B2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T706B2_STR-MANDT sy-vline
WA_T706B2_STR-MOREI sy-vline
WA_T706B2_STR-KZREA sy-vline
WA_T706B2_STR-BEREI sy-vline
WA_T706B2_STR-KZTKT sy-vline
WA_T706B2_STR-LNDGR sy-vline
WA_T706B2_STR-RGION sy-vline
WA_T706B2_STR-ERKLA sy-vline
WA_T706B2_STR-ERGRU sy-vline
WA_T706B2_STR-SPKZL sy-vline
WA_T706B2_STR-ATYPE sy-vline
WA_T706B2_STR-ENDDA sy-vline
WA_T706B2_STR-BEGDA sy-vline
WA_T706B2_STR-WAERS sy-vline
WA_T706B2_STR-BETRG sy-vline
WA_T706B2_STR-MSGID sy-vline
WA_T706B2_STR-MSGNO sy-vline
WA_T706B2_STR-DVAT sy-vline
WA_T706B2_STR-MAXDIFF sy-vline
WA_T706B2_STR-MAXDIFF_CURR sy-vline
WA_T706B2_STR-PERC_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.