ABAP Select data from SAP table T706L into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T706L table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T706L. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T706L table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T706L TYPE STANDARD TABLE OF T706L, WA_T706L TYPE T706L, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T706L> TYPE T706L. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T706L. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T706L INTO TABLE IT_T706L. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T706L * INTO TABLE @DATA(IT_T706L2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T706L INDEX 1 INTO DATA(WA_T706L2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T706L ASSIGNING <T706L>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T706L>-MANDT = 1.
<T706L>-MOREI = 1.
<T706L>-LAND1 = 1.
<T706L>-RGION = 1.
<T706L>-ENDDA = 1.
ENDLOOP. LOOP AT IT_T706L INTO WA_T706L. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T706L-BEGDA, sy-vline,
WA_T706L-LGRVE, sy-vline,
WA_T706L-LGRUN, sy-vline,
WA_T706L-LGRFA, sy-vline,
WA_T706L-REGVE, sy-vline,
WA_T706L-REGUN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T706L you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T706L TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T706L INTO WA_T706L. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T706L_STR,
MANDT TYPE STRING,
MOREI TYPE STRING,
LAND1 TYPE STRING,
RGION TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
LGRVE TYPE STRING,
LGRUN TYPE STRING,
LGRFA TYPE STRING,
REGVE TYPE STRING,
REGUN TYPE STRING,
REGFA TYPE STRING,
LGRHB TYPE STRING,
REGHB TYPE STRING,END OF T_EKKO_STR. DATA: WA_T706L_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T706L_STR-MANDT sy-vline
WA_T706L_STR-MOREI sy-vline
WA_T706L_STR-LAND1 sy-vline
WA_T706L_STR-RGION sy-vline
WA_T706L_STR-ENDDA sy-vline
WA_T706L_STR-BEGDA sy-vline
WA_T706L_STR-LGRVE sy-vline
WA_T706L_STR-LGRUN sy-vline
WA_T706L_STR-LGRFA sy-vline
WA_T706L_STR-REGVE sy-vline
WA_T706L_STR-REGUN sy-vline
WA_T706L_STR-REGFA sy-vline
WA_T706L_STR-LGRHB sy-vline
WA_T706L_STR-REGHB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.