ABAP Select data from SAP table T7EHS00_LABTESTG into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7EHS00_LABTESTG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7EHS00_LABTESTG. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T7EHS00_LABTESTG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T7EHS00_LABTESTG TYPE STANDARD TABLE OF T7EHS00_LABTESTG, WA_T7EHS00_LABTESTG TYPE T7EHS00_LABTESTG, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T7EHS00_LABTESTG> TYPE T7EHS00_LABTESTG. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T7EHS00_LABTESTG. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T7EHS00_LABTESTG INTO TABLE IT_T7EHS00_LABTESTG. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T7EHS00_LABTESTG * INTO TABLE @DATA(IT_T7EHS00_LABTESTG2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T7EHS00_LABTESTG INDEX 1 INTO DATA(WA_T7EHS00_LABTESTG2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T7EHS00_LABTESTG ASSIGNING <T7EHS00_LABTESTG>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7EHS00_LABTESTG>-MANDT = 1.
<T7EHS00_LABTESTG>-TEST_NO = 1.
<T7EHS00_LABTESTG>-GESCHLECHT = 1.
<T7EHS00_LABTESTG>-LAB_CODE = 1.
<T7EHS00_LABTESTG>-COMP_LAB_CODE = 1.
ENDLOOP. LOOP AT IT_T7EHS00_LABTESTG INTO WA_T7EHS00_LABTESTG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T7EHS00_LABTESTG-RESULT_UOM, sy-vline,
WA_T7EHS00_LABTESTG-RESULT_REF_RANGE, sy-vline,
WA_T7EHS00_LABTESTG-RESULT_NORM_L, sy-vline,
WA_T7EHS00_LABTESTG-RESULT_NORM_H, sy-vline,
WA_T7EHS00_LABTESTG-UPLOAD_FLAG, sy-vline,
WA_T7EHS00_LABTESTG-UNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7EHS00_LABTESTG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7EHS00_LABTESTG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7EHS00_LABTESTG INTO WA_T7EHS00_LABTESTG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field RESULT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_T7EHS00_LABTESTG-RESULT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T7EHS00_LABTESTG-RESULT_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7EHS00_LABTESTG_STR,
MANDT TYPE STRING,
TEST_NO TYPE STRING,
GESCHLECHT TYPE STRING,
LAB_CODE TYPE STRING,
COMP_LAB_CODE TYPE STRING,
RESULT_UOM TYPE STRING,
RESULT_REF_RANGE TYPE STRING,
RESULT_NORM_L TYPE STRING,
RESULT_NORM_H TYPE STRING,
UPLOAD_FLAG TYPE STRING,
UNAME TYPE STRING,
AEDTM TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7EHS00_LABTESTG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7EHS00_LABTESTG_STR-MANDT sy-vline
WA_T7EHS00_LABTESTG_STR-TEST_NO sy-vline
WA_T7EHS00_LABTESTG_STR-GESCHLECHT sy-vline
WA_T7EHS00_LABTESTG_STR-LAB_CODE sy-vline
WA_T7EHS00_LABTESTG_STR-COMP_LAB_CODE sy-vline
WA_T7EHS00_LABTESTG_STR-RESULT_UOM sy-vline
WA_T7EHS00_LABTESTG_STR-RESULT_REF_RANGE sy-vline
WA_T7EHS00_LABTESTG_STR-RESULT_NORM_L sy-vline
WA_T7EHS00_LABTESTG_STR-RESULT_NORM_H sy-vline
WA_T7EHS00_LABTESTG_STR-UPLOAD_FLAG sy-vline
WA_T7EHS00_LABTESTG_STR-UNAME sy-vline
WA_T7EHS00_LABTESTG_STR-AEDTM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.