ABAP Select data from SAP table T7IE6 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7IE6 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7IE6. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T7IE6 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T7IE6 TYPE STANDARD TABLE OF T7IE6, WA_T7IE6 TYPE T7IE6, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T7IE6> TYPE T7IE6. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T7IE6. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T7IE6 INTO TABLE IT_T7IE6. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T7IE6 * INTO TABLE @DATA(IT_T7IE62). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T7IE6 INDEX 1 INTO DATA(WA_T7IE62). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T7IE6 ASSIGNING <T7IE6>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7IE6>-MANDT = 1.
<T7IE6>-ERNIE = 1.
<T7IE6>-ENDDA = 1.
<T7IE6>-BEGDA = 1.
<T7IE6>-ENAME = 1.
ENDLOOP. LOOP AT IT_T7IE6 INTO WA_T7IE6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T7IE6-ADDR1, sy-vline,
WA_T7IE6-ADDR2, sy-vline,
WA_T7IE6-ADDR3, sy-vline,
WA_T7IE6-EUNIE, sy-vline,
WA_T7IE6-EANIE, sy-vline,
WA_T7IE6-FLIIE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T7IE6 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7IE6 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7IE6 INTO WA_T7IE6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7IE6_STR,
MANDT TYPE STRING,
ERNIE TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
ENAME TYPE STRING,
ADDR1 TYPE STRING,
ADDR2 TYPE STRING,
ADDR3 TYPE STRING,
EUNIE TYPE STRING,
EANIE TYPE STRING,
FLIIE TYPE STRING,
ATAIN TYPE STRING,
EWSS TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7IE6_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7IE6_STR-MANDT sy-vline
WA_T7IE6_STR-ERNIE sy-vline
WA_T7IE6_STR-ENDDA sy-vline
WA_T7IE6_STR-BEGDA sy-vline
WA_T7IE6_STR-ENAME sy-vline
WA_T7IE6_STR-ADDR1 sy-vline
WA_T7IE6_STR-ADDR2 sy-vline
WA_T7IE6_STR-ADDR3 sy-vline
WA_T7IE6_STR-EUNIE sy-vline
WA_T7IE6_STR-EANIE sy-vline
WA_T7IE6_STR-FLIIE sy-vline
WA_T7IE6_STR-ATAIN sy-vline
WA_T7IE6_STR-EWSS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.