ABAP Select data from SAP table T7RU_521B into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7RU_521B table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7RU_521B. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7RU_521B table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7RU_521B TYPE STANDARD TABLE OF T7RU_521B,
      WA_T7RU_521B TYPE T7RU_521B,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7RU_521B> TYPE T7RU_521B.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7RU_521B.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7RU_521B
  INTO TABLE IT_T7RU_521B.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7RU_521B
*  INTO TABLE @DATA(IT_T7RU_521B2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7RU_521B INDEX 1 INTO DATA(WA_T7RU_521B2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7RU_521B ASSIGNING <T7RU_521B>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7RU_521B>-MANDT = 1.
<T7RU_521B>-EMFSL = 1.
<T7RU_521B>-ENDDA = 1.
<T7RU_521B>-EMFTX = 1.
<T7RU_521B>-BNKNU = 1.
ENDLOOP.

LOOP AT IT_T7RU_521B INTO WA_T7RU_521B.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7RU_521B-LAND1, sy-vline,
WA_T7RU_521B-ORT02, sy-vline,
WA_T7RU_521B-ZLSCL, sy-vline,
WA_T7RU_521B-TRANS, sy-vline,
WA_T7RU_521B-STCD1, sy-vline,
ENDLOOP. *Add any further fields from structure WA_T7RU_521B you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7RU_521B TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7RU_521B INTO WA_T7RU_521B. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7RU_521B_STR,
MANDT TYPE STRING,
EMFSL TYPE STRING,
ENDDA TYPE STRING,
EMFTX TYPE STRING,
BNKNU TYPE STRING,
LAND1 TYPE STRING,
ORT02 TYPE STRING,
ZLSCL TYPE STRING,
TRANS TYPE STRING,
STCD1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7RU_521B_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7RU_521B_STR-MANDT sy-vline
WA_T7RU_521B_STR-EMFSL sy-vline
WA_T7RU_521B_STR-ENDDA sy-vline
WA_T7RU_521B_STR-EMFTX sy-vline
WA_T7RU_521B_STR-BNKNU sy-vline
WA_T7RU_521B_STR-LAND1 sy-vline
WA_T7RU_521B_STR-ORT02 sy-vline
WA_T7RU_521B_STR-ZLSCL sy-vline
WA_T7RU_521B_STR-TRANS sy-vline
WA_T7RU_521B_STR-STCD1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.