ABAP Select data from SAP table T7UNPAD_EG_GSS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T7UNPAD_EG_GSS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T7UNPAD_EG_GSS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T7UNPAD_EG_GSS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T7UNPAD_EG_GSS TYPE STANDARD TABLE OF T7UNPAD_EG_GSS,
      WA_T7UNPAD_EG_GSS TYPE T7UNPAD_EG_GSS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T7UNPAD_EG_GSS> TYPE T7UNPAD_EG_GSS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T7UNPAD_EG_GSS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T7UNPAD_EG_GSS
  INTO TABLE IT_T7UNPAD_EG_GSS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T7UNPAD_EG_GSS
*  INTO TABLE @DATA(IT_T7UNPAD_EG_GSS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T7UNPAD_EG_GSS INDEX 1 INTO DATA(WA_T7UNPAD_EG_GSS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T7UNPAD_EG_GSS ASSIGNING <T7UNPAD_EG_GSS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T7UNPAD_EG_GSS>-MANDT = 1.
<T7UNPAD_EG_GSS>-MOLGA = 1.
<T7UNPAD_EG_GSS>-EGSEQ_GSS = 1.
<T7UNPAD_EG_GSS>-EGIND = 1.
<T7UNPAD_EG_GSS>-ENDDA = 1.
ENDLOOP.

LOOP AT IT_T7UNPAD_EG_GSS INTO WA_T7UNPAD_EG_GSS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T7UNPAD_EG_GSS-BEGDA, sy-vline,
WA_T7UNPAD_EG_GSS-LOLMT, sy-vline,
WA_T7UNPAD_EG_GSS-HILMT, sy-vline,
WA_T7UNPAD_EG_GSS-REMB_PER, sy-vline,
WA_T7UNPAD_EG_GSS-EGCUR, sy-vline,
ENDLOOP. *Add any further fields from structure WA_T7UNPAD_EG_GSS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T7UNPAD_EG_GSS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T7UNPAD_EG_GSS INTO WA_T7UNPAD_EG_GSS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T7UNPAD_EG_GSS_STR,
MANDT TYPE STRING,
MOLGA TYPE STRING,
EGSEQ_GSS TYPE STRING,
EGIND TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
LOLMT TYPE STRING,
HILMT TYPE STRING,
REMB_PER TYPE STRING,
EGCUR TYPE STRING,END OF T_EKKO_STR. DATA: WA_T7UNPAD_EG_GSS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T7UNPAD_EG_GSS_STR-MANDT sy-vline
WA_T7UNPAD_EG_GSS_STR-MOLGA sy-vline
WA_T7UNPAD_EG_GSS_STR-EGSEQ_GSS sy-vline
WA_T7UNPAD_EG_GSS_STR-EGIND sy-vline
WA_T7UNPAD_EG_GSS_STR-ENDDA sy-vline
WA_T7UNPAD_EG_GSS_STR-BEGDA sy-vline
WA_T7UNPAD_EG_GSS_STR-LOLMT sy-vline
WA_T7UNPAD_EG_GSS_STR-HILMT sy-vline
WA_T7UNPAD_EG_GSS_STR-REMB_PER sy-vline
WA_T7UNPAD_EG_GSS_STR-EGCUR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.