ABAP Select data from SAP table T811DS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T811DS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T811DS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T811DS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T811DS TYPE STANDARD TABLE OF T811DS, WA_T811DS TYPE T811DS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T811DS> TYPE T811DS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T811DS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T811DS INTO TABLE IT_T811DS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T811DS * INTO TABLE @DATA(IT_T811DS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T811DS INDEX 1 INTO DATA(WA_T811DS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T811DS ASSIGNING <T811DS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T811DS>-MANDT = 1.
<T811DS>-TAB = 1.
<T811DS>-CYCLE = 1.
<T811DS>-SDATE = 1.
<T811DS>-SEGMENT = 1.
ENDLOOP. LOOP AT IT_T811DS INTO WA_T811DS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T811DS-GJAHR, sy-vline,
WA_T811DS-PERIO, sy-vline,
WA_T811DS-DPOS, sy-vline,
WA_T811DS-TYPE, sy-vline,
WA_T811DS-REBOOKPER, sy-vline,
WA_T811DS-REBOOKGJHR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T811DS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T811DS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T811DS INTO WA_T811DS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_T811DS-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T811DS-GJAHR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field REBOOKGJHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_T811DS-REBOOKGJHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T811DS-REBOOKGJHR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T811DS-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T811DS-DOCNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RDOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T811DS-RDOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T811DS-RDOC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T811DS_STR,
MANDT TYPE STRING,
TAB TYPE STRING,
CYCLE TYPE STRING,
SDATE TYPE STRING,
SEGMENT TYPE STRING,
GJAHR TYPE STRING,
PERIO TYPE STRING,
DPOS TYPE STRING,
TYPE TYPE STRING,
REBOOKPER TYPE STRING,
REBOOKGJHR TYPE STRING,
DOCNR TYPE STRING,
ADATE TYPE STRING,
RDOC TYPE STRING,
RDATE TYPE STRING,
REVERSED TYPE STRING,
ETAB TYPE STRING,
BISPE TYPE STRING,
NKROBJ TYPE STRING,
NKRSUB TYPE STRING,
NKRNNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_T811DS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T811DS_STR-MANDT sy-vline
WA_T811DS_STR-TAB sy-vline
WA_T811DS_STR-CYCLE sy-vline
WA_T811DS_STR-SDATE sy-vline
WA_T811DS_STR-SEGMENT sy-vline
WA_T811DS_STR-GJAHR sy-vline
WA_T811DS_STR-PERIO sy-vline
WA_T811DS_STR-DPOS sy-vline
WA_T811DS_STR-TYPE sy-vline
WA_T811DS_STR-REBOOKPER sy-vline
WA_T811DS_STR-REBOOKGJHR sy-vline
WA_T811DS_STR-DOCNR sy-vline
WA_T811DS_STR-ADATE sy-vline
WA_T811DS_STR-RDOC sy-vline
WA_T811DS_STR-RDATE sy-vline
WA_T811DS_STR-REVERSED sy-vline
WA_T811DS_STR-ETAB sy-vline
WA_T811DS_STR-BISPE sy-vline
WA_T811DS_STR-NKROBJ sy-vline
WA_T811DS_STR-NKRSUB sy-vline
WA_T811DS_STR-NKRNNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.