ABAP Select data from SAP table T863Y into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP T863Y table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T863Y. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the T863Y table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_T863Y TYPE STANDARD TABLE OF T863Y, WA_T863Y TYPE T863Y, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <T863Y> TYPE T863Y. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_T863Y. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM T863Y INTO TABLE IT_T863Y. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM T863Y * INTO TABLE @DATA(IT_T863Y2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_T863Y INDEX 1 INTO DATA(WA_T863Y2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_T863Y ASSIGNING <T863Y>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<T863Y>-MANDT = 1.
<T863Y>-RSUBD = 1.
<T863Y>-RYEAR = 1.
<T863Y>-PEVON = 1.
<T863Y>-PEBIS = 1.
ENDLOOP. LOOP AT IT_T863Y INTO WA_T863Y. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_T863Y-RVERS, sy-vline,
WA_T863Y-RRCTY, sy-vline,
WA_T863Y-WATYP, sy-vline,
WA_T863Y-INDXNAME, sy-vline,
WA_T863Y-INDXNO, sy-vline,
WA_T863Y-GENDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T863Y you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T863Y TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T863Y INTO WA_T863Y. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_T863Y-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T863Y-RYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T863Y-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T863Y-RVERS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T863Y_STR,
MANDT TYPE STRING,
RSUBD TYPE STRING,
RYEAR TYPE STRING,
PEVON TYPE STRING,
PEBIS TYPE STRING,
RVERS TYPE STRING,
RRCTY TYPE STRING,
WATYP TYPE STRING,
INDXNAME TYPE STRING,
INDXNO TYPE STRING,
GENDAT TYPE STRING,
GESANT TYPE STRING,
PARTANT TYPE STRING,
GENOLD TYPE STRING,END OF T_EKKO_STR. DATA: WA_T863Y_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T863Y_STR-MANDT sy-vline
WA_T863Y_STR-RSUBD sy-vline
WA_T863Y_STR-RYEAR sy-vline
WA_T863Y_STR-PEVON sy-vline
WA_T863Y_STR-PEBIS sy-vline
WA_T863Y_STR-RVERS sy-vline
WA_T863Y_STR-RRCTY sy-vline
WA_T863Y_STR-WATYP sy-vline
WA_T863Y_STR-INDXNAME sy-vline
WA_T863Y_STR-INDXNO sy-vline
WA_T863Y_STR-GENDAT sy-vline
WA_T863Y_STR-GESANT sy-vline
WA_T863Y_STR-PARTANT sy-vline
WA_T863Y_STR-GENOLD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.