ABAP Select data from SAP table T895PCA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP T895PCA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to T895PCA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the T895PCA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_T895PCA TYPE STANDARD TABLE OF T895PCA,
      WA_T895PCA TYPE T895PCA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <T895PCA> TYPE T895PCA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_T895PCA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM T895PCA
  INTO TABLE IT_T895PCA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM T895PCA
*  INTO TABLE @DATA(IT_T895PCA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_T895PCA INDEX 1 INTO DATA(WA_T895PCA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_T895PCA ASSIGNING <T895PCA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<T895PCA>-MANDT = 1.
<T895PCA>-KOKRS = 1.
<T895PCA>-RLDNR = 1.
<T895PCA>-RVERS = 1.
<T895PCA>-RYEAR = 1.
ENDLOOP.

LOOP AT IT_T895PCA INTO WA_T895PCA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_T895PCA-ONLKZ, sy-vline,
WA_T895PCA-EPSKZ, sy-vline,
WA_T895PCA-VSPKZ, sy-vline,
WA_T895PCA-KURST, sy-vline,
WA_T895PCA-PLDAT, sy-vline,
WA_T895PCA-VARIANT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_T895PCA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_T895PCA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_T895PCA INTO WA_T895PCA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T895PCA-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T895PCA-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T895PCA-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T895PCA-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_T895PCA-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T895PCA-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_T895PCA-VARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_T895PCA-VARIANT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_T895PCA_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
RLDNR TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
ONLKZ TYPE STRING,
EPSKZ TYPE STRING,
VSPKZ TYPE STRING,
KURST TYPE STRING,
PLDAT TYPE STRING,
VARIANT TYPE STRING,END OF T_EKKO_STR. DATA: WA_T895PCA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_T895PCA_STR-MANDT sy-vline
WA_T895PCA_STR-KOKRS sy-vline
WA_T895PCA_STR-RLDNR sy-vline
WA_T895PCA_STR-RVERS sy-vline
WA_T895PCA_STR-RYEAR sy-vline
WA_T895PCA_STR-ONLKZ sy-vline
WA_T895PCA_STR-EPSKZ sy-vline
WA_T895PCA_STR-VSPKZ sy-vline
WA_T895PCA_STR-KURST sy-vline
WA_T895PCA_STR-PLDAT sy-vline
WA_T895PCA_STR-VARIANT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.