ABAP Select data from SAP table TCRV_CTY_FWDRATE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TCRV_CTY_FWDRATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TCRV_CTY_FWDRATE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TCRV_CTY_FWDRATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TCRV_CTY_FWDRATE TYPE STANDARD TABLE OF TCRV_CTY_FWDRATE, WA_TCRV_CTY_FWDRATE TYPE TCRV_CTY_FWDRATE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TCRV_CTY_FWDRATE> TYPE TCRV_CTY_FWDRATE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TCRV_CTY_FWDRATE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TCRV_CTY_FWDRATE INTO TABLE IT_TCRV_CTY_FWDRATE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TCRV_CTY_FWDRATE * INTO TABLE @DATA(IT_TCRV_CTY_FWDRATE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TCRV_CTY_FWDRATE INDEX 1 INTO DATA(WA_TCRV_CTY_FWDRATE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TCRV_CTY_FWDRATE ASSIGNING <TCRV_CTY_FWDRATE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TCRV_CTY_FWDRATE>-MANDT = 1.
<TCRV_CTY_FWDRATE>-COMMODITY_ID = 1.
<TCRV_CTY_FWDRATE>-PROVIDER = 1.
<TCRV_CTY_FWDRATE>-QUOT_DATE = 1.
<TCRV_CTY_FWDRATE>-QUOT_TYPE = 1.
ENDLOOP. LOOP AT IT_TCRV_CTY_FWDRATE INTO WA_TCRV_CTY_FWDRATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TCRV_CTY_FWDRATE-PERIOD_START, sy-vline,
WA_TCRV_CTY_FWDRATE-PERIOD_TYPE, sy-vline,
WA_TCRV_CTY_FWDRATE-TIMESTAMP, sy-vline,
WA_TCRV_CTY_FWDRATE-QUOT_VALUE, sy-vline,
WA_TCRV_CTY_FWDRATE-QUOT_UOM, sy-vline,
WA_TCRV_CTY_FWDRATE-QUOT_CURR_UNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TCRV_CTY_FWDRATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TCRV_CTY_FWDRATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TCRV_CTY_FWDRATE INTO WA_TCRV_CTY_FWDRATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field QUOT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TCRV_CTY_FWDRATE-QUOT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TCRV_CTY_FWDRATE-QUOT_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TCRV_CTY_FWDRATE_STR,
MANDT TYPE STRING,
COMMODITY_ID TYPE STRING,
PROVIDER TYPE STRING,
QUOT_DATE TYPE STRING,
QUOT_TYPE TYPE STRING,
PERIOD_START TYPE STRING,
PERIOD_TYPE TYPE STRING,
TIMESTAMP TYPE STRING,
QUOT_VALUE TYPE STRING,
QUOT_UOM TYPE STRING,
QUOT_CURR_UNIT TYPE STRING,
ENTERED_BY TYPE STRING,
PERIOD_END TYPE STRING,
DELETED TYPE STRING,END OF T_EKKO_STR. DATA: WA_TCRV_CTY_FWDRATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TCRV_CTY_FWDRATE_STR-MANDT sy-vline
WA_TCRV_CTY_FWDRATE_STR-COMMODITY_ID sy-vline
WA_TCRV_CTY_FWDRATE_STR-PROVIDER sy-vline
WA_TCRV_CTY_FWDRATE_STR-QUOT_DATE sy-vline
WA_TCRV_CTY_FWDRATE_STR-QUOT_TYPE sy-vline
WA_TCRV_CTY_FWDRATE_STR-PERIOD_START sy-vline
WA_TCRV_CTY_FWDRATE_STR-PERIOD_TYPE sy-vline
WA_TCRV_CTY_FWDRATE_STR-TIMESTAMP sy-vline
WA_TCRV_CTY_FWDRATE_STR-QUOT_VALUE sy-vline
WA_TCRV_CTY_FWDRATE_STR-QUOT_UOM sy-vline
WA_TCRV_CTY_FWDRATE_STR-QUOT_CURR_UNIT sy-vline
WA_TCRV_CTY_FWDRATE_STR-ENTERED_BY sy-vline
WA_TCRV_CTY_FWDRATE_STR-PERIOD_END sy-vline
WA_TCRV_CTY_FWDRATE_STR-DELETED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.