Below is a number of ABAP code snippets to demonstrate how to select data from SAP TEMCNV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TEMCNV. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TEMCNV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TEMCNV TYPE STANDARD TABLE OF TEMCNV, WA_TEMCNV TYPE TEMCNV, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TEMCNV> TYPE TEMCNV. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TEMCNV. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TEMCNV INTO TABLE IT_TEMCNV. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TEMCNV * INTO TABLE @DATA(IT_TEMCNV2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TEMCNV INDEX 1 INTO DATA(WA_TEMCNV2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TEMCNV ASSIGNING <TEMCNV>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TEMCNV>-CONVOBJECT = 1.
<TEMCNV>-DOMA = 1.
<TEMCNV>-LEN_INPUT = 1.
<TEMCNV>-TYPE_INPUT = 1.
<TEMCNV>-CASE_INPUT = 1.
ENDLOOP. LOOP AT IT_TEMCNV INTO WA_TEMCNV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TEMCNV-LEN_OUTPUT, sy-vline,
WA_TEMCNV-TYPE_OUTPUT, sy-vline,
WA_TEMCNV-CASE_OUTPUT, sy-vline,
WA_TEMCNV-ERR_DEFVAL, sy-vline,
WA_TEMCNV-ERR_INVAL, sy-vline,
WA_TEMCNV-ERR_INITIAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TEMCNV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TEMCNV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TEMCNV INTO WA_TEMCNV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TEMCNV_STR,
CONVOBJECT TYPE STRING,
DOMA TYPE STRING,
LEN_INPUT TYPE STRING,
TYPE_INPUT TYPE STRING,
CASE_INPUT TYPE STRING,
LEN_OUTPUT TYPE STRING,
TYPE_OUTPUT TYPE STRING,
CASE_OUTPUT TYPE STRING,
ERR_DEFVAL TYPE STRING,
ERR_INVAL TYPE STRING,
ERR_INITIAL TYPE STRING,
ERR_ERROR TYPE STRING,
DATUM1 TYPE STRING,
UNAME1 TYPE STRING,
DATUM2 TYPE STRING,
UZEIT2 TYPE STRING,
UNAME2 TYPE STRING,
DEFVAL TYPE STRING,
INITCONV TYPE STRING,END OF T_EKKO_STR. DATA: WA_TEMCNV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TEMCNV_STR-CONVOBJECT sy-vline
WA_TEMCNV_STR-DOMA sy-vline
WA_TEMCNV_STR-LEN_INPUT sy-vline
WA_TEMCNV_STR-TYPE_INPUT sy-vline
WA_TEMCNV_STR-CASE_INPUT sy-vline
WA_TEMCNV_STR-LEN_OUTPUT sy-vline
WA_TEMCNV_STR-TYPE_OUTPUT sy-vline
WA_TEMCNV_STR-CASE_OUTPUT sy-vline
WA_TEMCNV_STR-ERR_DEFVAL sy-vline
WA_TEMCNV_STR-ERR_INVAL sy-vline
WA_TEMCNV_STR-ERR_INITIAL sy-vline
WA_TEMCNV_STR-ERR_ERROR sy-vline
WA_TEMCNV_STR-DATUM1 sy-vline
WA_TEMCNV_STR-UNAME1 sy-vline
WA_TEMCNV_STR-DATUM2 sy-vline
WA_TEMCNV_STR-UZEIT2 sy-vline
WA_TEMCNV_STR-UNAME2 sy-vline
WA_TEMCNV_STR-DEFVAL sy-vline
WA_TEMCNV_STR-INITCONV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.