ABAP Select data from SAP table TERS_QUANT_DISPLAY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TERS_QUANT_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TERS_QUANT_DISPLAY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TERS_QUANT_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TERS_QUANT_DISPLAY TYPE STANDARD TABLE OF TERS_QUANT_DISPLAY,
      WA_TERS_QUANT_DISPLAY TYPE TERS_QUANT_DISPLAY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TERS_QUANT_DISPLAY> TYPE TERS_QUANT_DISPLAY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TERS_QUANT_DISPLAY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TERS_QUANT_DISPLAY
  INTO TABLE IT_TERS_QUANT_DISPLAY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TERS_QUANT_DISPLAY
*  INTO TABLE @DATA(IT_TERS_QUANT_DISPLAY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TERS_QUANT_DISPLAY INDEX 1 INTO DATA(WA_TERS_QUANT_DISPLAY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TERS_QUANT_DISPLAY ASSIGNING <TERS_QUANT_DISPLAY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TERS_QUANT_DISPLAY>-MARK4 = 1.
<TERS_QUANT_DISPLAY>-AMOUNT = 1.
<TERS_QUANT_DISPLAY>-CURRENCY = 1.
<TERS_QUANT_DISPLAY>-FLOWS1 = 1.
<TERS_QUANT_DISPLAY>-FLOWS1_TEXT = 1.
ENDLOOP.

LOOP AT IT_TERS_QUANT_DISPLAY INTO WA_TERS_QUANT_DISPLAY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TERS_QUANT_DISPLAY-FLOWS2, sy-vline,
WA_TERS_QUANT_DISPLAY-FLOWS2_TEXT, sy-vline,
WA_TERS_QUANT_DISPLAY-FLOWS3, sy-vline,
WA_TERS_QUANT_DISPLAY-FLOWS3_TEXT, sy-vline,
WA_TERS_QUANT_DISPLAY-COM_VAL_CLASS, sy-vline,
WA_TERS_QUANT_DISPLAY-COMPANY_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TERS_QUANT_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TERS_QUANT_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TERS_QUANT_DISPLAY INTO WA_TERS_QUANT_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SECURITY_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TERS_QUANT_DISPLAY-SECURITY_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TERS_QUANT_DISPLAY-SECURITY_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TERS_QUANT_DISPLAY-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TERS_QUANT_DISPLAY-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field WBS_ELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_TERS_QUANT_DISPLAY-WBS_ELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TERS_QUANT_DISPLAY-WBS_ELEMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COST_CENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TERS_QUANT_DISPLAY-COST_CENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TERS_QUANT_DISPLAY-COST_CENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PROFIT_CENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TERS_QUANT_DISPLAY-PROFIT_CENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TERS_QUANT_DISPLAY-PROFIT_CENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TERS_QUANT_DISPLAY_STR,
MARK4 TYPE STRING,
AMOUNT TYPE STRING,
CURRENCY TYPE STRING,
FLOWS1 TYPE STRING,
FLOWS1_TEXT TYPE STRING,
FLOWS2 TYPE STRING,
FLOWS2_TEXT TYPE STRING,
FLOWS3 TYPE STRING,
FLOWS3_TEXT TYPE STRING,
COM_VAL_CLASS TYPE STRING,
COMPANY_CODE TYPE STRING,
VALUATION_AREA TYPE STRING,
SECURITY_ACCOUNT TYPE STRING,
SECURITY_ID TYPE STRING,
PORTFOLIO TYPE STRING,
TRADER TYPE STRING,
POSITION_ACCOUNT TYPE STRING,
FLAG_LONG_SHORT TYPE STRING,
FUND TYPE STRING,
GRANT_NBR TYPE STRING,
WBS_ELEMENT TYPE STRING,
COST_CENTER TYPE STRING,
PROFIT_CENTER TYPE STRING,
FUNCTIONAL_AREA TYPE STRING,
SECURITY_ACCOUNT2 TYPE STRING,
COM_VAL_CLASS2 TYPE STRING,
PORTFOLIO2 TYPE STRING,
NOMINAL_AMT TYPE STRING,
NOMINAL_ORG_AMT TYPE STRING,
NOMINAL_CURR TYPE STRING,
UNITS TYPE STRING,
NOMINAL_ER TYPE STRING,
NOMINAL_ORG_ER TYPE STRING,
UNITS_ER TYPE STRING,
FLG_NOAUTH TYPE STRING,END OF T_EKKO_STR. DATA: WA_TERS_QUANT_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TERS_QUANT_DISPLAY_STR-MARK4 sy-vline
WA_TERS_QUANT_DISPLAY_STR-AMOUNT sy-vline
WA_TERS_QUANT_DISPLAY_STR-CURRENCY sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS1 sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS1_TEXT sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS2 sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS2_TEXT sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS3 sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLOWS3_TEXT sy-vline
WA_TERS_QUANT_DISPLAY_STR-COM_VAL_CLASS sy-vline
WA_TERS_QUANT_DISPLAY_STR-COMPANY_CODE sy-vline
WA_TERS_QUANT_DISPLAY_STR-VALUATION_AREA sy-vline
WA_TERS_QUANT_DISPLAY_STR-SECURITY_ACCOUNT sy-vline
WA_TERS_QUANT_DISPLAY_STR-SECURITY_ID sy-vline
WA_TERS_QUANT_DISPLAY_STR-PORTFOLIO sy-vline
WA_TERS_QUANT_DISPLAY_STR-TRADER sy-vline
WA_TERS_QUANT_DISPLAY_STR-POSITION_ACCOUNT sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLAG_LONG_SHORT sy-vline
WA_TERS_QUANT_DISPLAY_STR-FUND sy-vline
WA_TERS_QUANT_DISPLAY_STR-GRANT_NBR sy-vline
WA_TERS_QUANT_DISPLAY_STR-WBS_ELEMENT sy-vline
WA_TERS_QUANT_DISPLAY_STR-COST_CENTER sy-vline
WA_TERS_QUANT_DISPLAY_STR-PROFIT_CENTER sy-vline
WA_TERS_QUANT_DISPLAY_STR-FUNCTIONAL_AREA sy-vline
WA_TERS_QUANT_DISPLAY_STR-SECURITY_ACCOUNT2 sy-vline
WA_TERS_QUANT_DISPLAY_STR-COM_VAL_CLASS2 sy-vline
WA_TERS_QUANT_DISPLAY_STR-PORTFOLIO2 sy-vline
WA_TERS_QUANT_DISPLAY_STR-NOMINAL_AMT sy-vline
WA_TERS_QUANT_DISPLAY_STR-NOMINAL_ORG_AMT sy-vline
WA_TERS_QUANT_DISPLAY_STR-NOMINAL_CURR sy-vline
WA_TERS_QUANT_DISPLAY_STR-UNITS sy-vline
WA_TERS_QUANT_DISPLAY_STR-NOMINAL_ER sy-vline
WA_TERS_QUANT_DISPLAY_STR-NOMINAL_ORG_ER sy-vline
WA_TERS_QUANT_DISPLAY_STR-UNITS_ER sy-vline
WA_TERS_QUANT_DISPLAY_STR-FLG_NOAUTH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.