ABAP Select data from SAP table TISSR_TP_C_DYNF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TISSR_TP_C_DYNF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TISSR_TP_C_DYNF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TISSR_TP_C_DYNF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TISSR_TP_C_DYNF TYPE STANDARD TABLE OF TISSR_TP_C_DYNF, WA_TISSR_TP_C_DYNF TYPE TISSR_TP_C_DYNF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TISSR_TP_C_DYNF> TYPE TISSR_TP_C_DYNF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TISSR_TP_C_DYNF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TISSR_TP_C_DYNF INTO TABLE IT_TISSR_TP_C_DYNF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TISSR_TP_C_DYNF * INTO TABLE @DATA(IT_TISSR_TP_C_DYNF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TISSR_TP_C_DYNF INDEX 1 INTO DATA(WA_TISSR_TP_C_DYNF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TISSR_TP_C_DYNF ASSIGNING <TISSR_TP_C_DYNF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TISSR_TP_C_DYNF>-MANDT = 1.
<TISSR_TP_C_DYNF>-COUNTRY_VAR = 1.
<TISSR_TP_C_DYNF>-REPID = 1.
<TISSR_TP_C_DYNF>-DYNNR = 1.
<TISSR_TP_C_DYNF>-STRUCNAME = 1.
ENDLOOP. LOOP AT IT_TISSR_TP_C_DYNF INTO WA_TISSR_TP_C_DYNF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TISSR_TP_C_DYNF-FIELDNAME, sy-vline,
WA_TISSR_TP_C_DYNF-TXT_STRUCNAME, sy-vline,
WA_TISSR_TP_C_DYNF-INVISIBLE, sy-vline,
WA_TISSR_TP_C_DYNF-REQUIRED, sy-vline,
WA_TISSR_TP_C_DYNF-FIELD_INPUT, sy-vline,
WA_TISSR_TP_C_DYNF-FIELD_OUTPUT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TISSR_TP_C_DYNF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TISSR_TP_C_DYNF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TISSR_TP_C_DYNF INTO WA_TISSR_TP_C_DYNF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TISSR_TP_C_DYNF_STR,
MANDT TYPE STRING,
COUNTRY_VAR TYPE STRING,
REPID TYPE STRING,
DYNNR TYPE STRING,
STRUCNAME TYPE STRING,
FIELDNAME TYPE STRING,
TXT_STRUCNAME TYPE STRING,
INVISIBLE TYPE STRING,
REQUIRED TYPE STRING,
FIELD_INPUT TYPE STRING,
FIELD_OUTPUT TYPE STRING,
FIELD_INITIAL TYPE STRING,
FIELD_CHECK TYPE STRING,
CHECK_TABLE TYPE STRING,
RANKING TYPE STRING,
DISPL_RANTP_ONLY TYPE STRING,
ASSET_TYPE_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_TISSR_TP_C_DYNF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TISSR_TP_C_DYNF_STR-MANDT sy-vline
WA_TISSR_TP_C_DYNF_STR-COUNTRY_VAR sy-vline
WA_TISSR_TP_C_DYNF_STR-REPID sy-vline
WA_TISSR_TP_C_DYNF_STR-DYNNR sy-vline
WA_TISSR_TP_C_DYNF_STR-STRUCNAME sy-vline
WA_TISSR_TP_C_DYNF_STR-FIELDNAME sy-vline
WA_TISSR_TP_C_DYNF_STR-TXT_STRUCNAME sy-vline
WA_TISSR_TP_C_DYNF_STR-INVISIBLE sy-vline
WA_TISSR_TP_C_DYNF_STR-REQUIRED sy-vline
WA_TISSR_TP_C_DYNF_STR-FIELD_INPUT sy-vline
WA_TISSR_TP_C_DYNF_STR-FIELD_OUTPUT sy-vline
WA_TISSR_TP_C_DYNF_STR-FIELD_INITIAL sy-vline
WA_TISSR_TP_C_DYNF_STR-FIELD_CHECK sy-vline
WA_TISSR_TP_C_DYNF_STR-CHECK_TABLE sy-vline
WA_TISSR_TP_C_DYNF_STR-RANKING sy-vline
WA_TISSR_TP_C_DYNF_STR-DISPL_RANTP_ONLY sy-vline
WA_TISSR_TP_C_DYNF_STR-ASSET_TYPE_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.