ABAP Select data from SAP table TMETRIC_ENTRY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TMETRIC_ENTRY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TMETRIC_ENTRY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TMETRIC_ENTRY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TMETRIC_ENTRY TYPE STANDARD TABLE OF TMETRIC_ENTRY, WA_TMETRIC_ENTRY TYPE TMETRIC_ENTRY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TMETRIC_ENTRY> TYPE TMETRIC_ENTRY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TMETRIC_ENTRY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TMETRIC_ENTRY INTO TABLE IT_TMETRIC_ENTRY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TMETRIC_ENTRY * INTO TABLE @DATA(IT_TMETRIC_ENTRY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TMETRIC_ENTRY INDEX 1 INTO DATA(WA_TMETRIC_ENTRY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TMETRIC_ENTRY ASSIGNING <TMETRIC_ENTRY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TMETRIC_ENTRY>-CLIENT = 1.
<TMETRIC_ENTRY>-NAME = 1.
<TMETRIC_ENTRY>-ENTRY_KEY = 1.
<TMETRIC_ENTRY>-FIELD_NAME = 1.
<TMETRIC_ENTRY>-FIELD_LOW = 1.
ENDLOOP. LOOP AT IT_TMETRIC_ENTRY INTO WA_TMETRIC_ENTRY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TMETRIC_ENTRY-FIELD_HIGH, sy-vline,
WA_TMETRIC_ENTRY-FIELD_OPTION, sy-vline,
WA_TMETRIC_ENTRY-FIELD_SIGN, sy-vline,
WA_TMETRIC_ENTRY-ORDER_NUMBER, sy-vline,
WA_TMETRIC_ENTRY-PARENT_ENTRY, sy-vline,
WA_TMETRIC_ENTRY-RESIDENCE_TIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TMETRIC_ENTRY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TMETRIC_ENTRY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TMETRIC_ENTRY INTO WA_TMETRIC_ENTRY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TMETRIC_ENTRY_STR,
CLIENT TYPE STRING,
NAME TYPE STRING,
ENTRY_KEY TYPE STRING,
FIELD_NAME TYPE STRING,
FIELD_LOW TYPE STRING,
FIELD_HIGH TYPE STRING,
FIELD_OPTION TYPE STRING,
FIELD_SIGN TYPE STRING,
ORDER_NUMBER TYPE STRING,
PARENT_ENTRY TYPE STRING,
RESIDENCE_TIME TYPE STRING,
RESIDENCE_UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_TMETRIC_ENTRY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TMETRIC_ENTRY_STR-CLIENT sy-vline
WA_TMETRIC_ENTRY_STR-NAME sy-vline
WA_TMETRIC_ENTRY_STR-ENTRY_KEY sy-vline
WA_TMETRIC_ENTRY_STR-FIELD_NAME sy-vline
WA_TMETRIC_ENTRY_STR-FIELD_LOW sy-vline
WA_TMETRIC_ENTRY_STR-FIELD_HIGH sy-vline
WA_TMETRIC_ENTRY_STR-FIELD_OPTION sy-vline
WA_TMETRIC_ENTRY_STR-FIELD_SIGN sy-vline
WA_TMETRIC_ENTRY_STR-ORDER_NUMBER sy-vline
WA_TMETRIC_ENTRY_STR-PARENT_ENTRY sy-vline
WA_TMETRIC_ENTRY_STR-RESIDENCE_TIME sy-vline
WA_TMETRIC_ENTRY_STR-RESIDENCE_UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.