ABAP Select data from SAP table TN2DEVICES into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TN2DEVICES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TN2DEVICES. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TN2DEVICES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TN2DEVICES TYPE STANDARD TABLE OF TN2DEVICES, WA_TN2DEVICES TYPE TN2DEVICES, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TN2DEVICES> TYPE TN2DEVICES. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TN2DEVICES. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TN2DEVICES INTO TABLE IT_TN2DEVICES. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TN2DEVICES * INTO TABLE @DATA(IT_TN2DEVICES2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TN2DEVICES INDEX 1 INTO DATA(WA_TN2DEVICES2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TN2DEVICES ASSIGNING <TN2DEVICES>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TN2DEVICES>-MANDT = 1.
<TN2DEVICES>-EINRI = 1.
<TN2DEVICES>-SDEST = 1.
<TN2DEVICES>-TNAME = 1.
<TN2DEVICES>-SEPARATER = 1.
ENDLOOP. LOOP AT IT_TN2DEVICES INTO WA_TN2DEVICES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TN2DEVICES-DATEFORMAT, sy-vline,
WA_TN2DEVICES-TIMEFORMAT, sy-vline,
WA_TN2DEVICES-SEX_FEMALE, sy-vline,
WA_TN2DEVICES-SEX_MALE, sy-vline,
WA_TN2DEVICES-NOT_AVAILABLE, sy-vline,
WA_TN2DEVICES-OUT_OF_RANGE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TN2DEVICES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TN2DEVICES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TN2DEVICES INTO WA_TN2DEVICES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TN2DEVICES-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TN2DEVICES-EINRI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TN2DEVICES-LSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TN2DEVICES-LSYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TN2DEVICES_STR,
MANDT TYPE STRING,
EINRI TYPE STRING,
SDEST TYPE STRING,
TNAME TYPE STRING,
SEPARATER TYPE STRING,
DATEFORMAT TYPE STRING,
TIMEFORMAT TYPE STRING,
SEX_FEMALE TYPE STRING,
SEX_MALE TYPE STRING,
NOT_AVAILABLE TYPE STRING,
OUT_OF_RANGE TYPE STRING,
MIMETYPE TYPE STRING,
LSYSTEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_TN2DEVICES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TN2DEVICES_STR-MANDT sy-vline
WA_TN2DEVICES_STR-EINRI sy-vline
WA_TN2DEVICES_STR-SDEST sy-vline
WA_TN2DEVICES_STR-TNAME sy-vline
WA_TN2DEVICES_STR-SEPARATER sy-vline
WA_TN2DEVICES_STR-DATEFORMAT sy-vline
WA_TN2DEVICES_STR-TIMEFORMAT sy-vline
WA_TN2DEVICES_STR-SEX_FEMALE sy-vline
WA_TN2DEVICES_STR-SEX_MALE sy-vline
WA_TN2DEVICES_STR-NOT_AVAILABLE sy-vline
WA_TN2DEVICES_STR-OUT_OF_RANGE sy-vline
WA_TN2DEVICES_STR-MIMETYPE sy-vline
WA_TN2DEVICES_STR-LSYSTEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.