ABAP Select data from SAP table U_15193 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_15193 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_15193. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_15193 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_15193 TYPE STANDARD TABLE OF U_15193,
      WA_U_15193 TYPE U_15193,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_15193> TYPE U_15193.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_15193.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_15193
  INTO TABLE IT_U_15193.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_15193
*  INTO TABLE @DATA(IT_U_151932).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_15193 INDEX 1 INTO DATA(WA_U_151932).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_15193 ASSIGNING <U_15193>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_15193>-MANDT = 1.
<U_15193>-RSNUM = 1.
<U_15193>-RSPOS = 1.
<U_15193>-RSART = 1.
<U_15193>-WERKS = 1.
ENDLOOP.

LOOP AT IT_U_15193 INTO WA_U_15193.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_15193-MATNR, sy-vline,
WA_U_15193-RSSTA, sy-vline,
WA_U_15193-EBELN, sy-vline,
WA_U_15193-EBELP, sy-vline,
WA_U_15193-EBELE, sy-vline,
WA_U_15193-XLOEK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_15193 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_15193 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_15193 INTO WA_U_15193. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_U_15193-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_15193-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_15193-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_15193-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_U_15193-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_U_15193-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_15193-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_15193-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_15193_STR,
MANDT TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
RSART TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
RSSTA TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
EBELE TYPE STRING,
XLOEK TYPE STRING,
BDTER TYPE STRING,
BDMNG TYPE STRING,
MEINS TYPE STRING,
SHKZG TYPE STRING,
BWART TYPE STRING,
SAKNR TYPE STRING,
POSTP TYPE STRING,
POSNR TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLKN TYPE STRING,
STPOZ TYPE STRING,
AENNR TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
SBTER TYPE STRING,
SCHGT TYPE STRING,
OBJNR TYPE STRING,
LGPLA TYPE STRING,
BDZTP TYPE STRING,
ALPST TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_15193_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_15193_STR-MANDT sy-vline
WA_U_15193_STR-RSNUM sy-vline
WA_U_15193_STR-RSPOS sy-vline
WA_U_15193_STR-RSART sy-vline
WA_U_15193_STR-WERKS sy-vline
WA_U_15193_STR-MATNR sy-vline
WA_U_15193_STR-RSSTA sy-vline
WA_U_15193_STR-EBELN sy-vline
WA_U_15193_STR-EBELP sy-vline
WA_U_15193_STR-EBELE sy-vline
WA_U_15193_STR-XLOEK sy-vline
WA_U_15193_STR-BDTER sy-vline
WA_U_15193_STR-BDMNG sy-vline
WA_U_15193_STR-MEINS sy-vline
WA_U_15193_STR-SHKZG sy-vline
WA_U_15193_STR-BWART sy-vline
WA_U_15193_STR-SAKNR sy-vline
WA_U_15193_STR-POSTP sy-vline
WA_U_15193_STR-POSNR sy-vline
WA_U_15193_STR-STLTY sy-vline
WA_U_15193_STR-STLNR sy-vline
WA_U_15193_STR-STLKN sy-vline
WA_U_15193_STR-STPOZ sy-vline
WA_U_15193_STR-AENNR sy-vline
WA_U_15193_STR-UMREZ sy-vline
WA_U_15193_STR-UMREN sy-vline
WA_U_15193_STR-SBTER sy-vline
WA_U_15193_STR-SCHGT sy-vline
WA_U_15193_STR-OBJNR sy-vline
WA_U_15193_STR-LGPLA sy-vline
WA_U_15193_STR-BDZTP sy-vline
WA_U_15193_STR-ALPST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.