ABAP Select data from SAP table U_25613 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_25613 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_25613. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_25613 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_25613 TYPE STANDARD TABLE OF U_25613,
      WA_U_25613 TYPE U_25613,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_25613> TYPE U_25613.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_25613.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_25613
  INTO TABLE IT_U_25613.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_25613
*  INTO TABLE @DATA(IT_U_256132).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_25613 INDEX 1 INTO DATA(WA_U_256132).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_25613 ASSIGNING <U_25613>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_25613>-MANDT = 1.
<U_25613>-AUFNR = 1.
<U_25613>-ARTPR = 1.
<U_25613>-PRIOK = 1.
<U_25613>-EQUNR = 1.
ENDLOOP.

LOOP AT IT_U_25613 INTO WA_U_25613.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_25613-BAUTL, sy-vline,
WA_U_25613-ILOAN, sy-vline,
WA_U_25613-ILOAI, sy-vline,
WA_U_25613-ANLZU, sy-vline,
WA_U_25613-IWERK, sy-vline,
WA_U_25613-INGPR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_25613 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_25613 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_25613 INTO WA_U_25613. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_U_25613-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-KUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GAUEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_25613-GAUEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-GAUEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WARPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-WARPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-WARPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-LAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-LAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-KOSTV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-KOSTV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CYCLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-CYCLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-CYCLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_U_25613-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCOPE, internal->external for field SCOPE CALL FUNCTION 'CONVERSION_EXIT_SCOPE_OUTPUT' EXPORTING input = WA_U_25613-SCOPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-SCOPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-AKSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-AKSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NTZUE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25613-NTZUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-NTZUE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORUE CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_U_25613-VORUE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25613-VORUE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_25613_STR,
MANDT TYPE STRING,
AUFNR TYPE STRING,
ARTPR TYPE STRING,
PRIOK TYPE STRING,
EQUNR TYPE STRING,
BAUTL TYPE STRING,
ILOAN TYPE STRING,
ILOAI TYPE STRING,
ANLZU TYPE STRING,
IWERK TYPE STRING,
INGPR TYPE STRING,
APGRP TYPE STRING,
PM_OBJTY TYPE STRING,
GEWRK TYPE STRING,
KUNUM TYPE STRING,
ANING TYPE STRING,
GAUZT TYPE STRING,
GAUEH TYPE STRING,
ANLBD TYPE STRING,
ANLVD TYPE STRING,
ANLBZ TYPE STRING,
ANLVZ TYPE STRING,
INSPK TYPE STRING,
DATAN TYPE STRING,
WARPL TYPE STRING,
ABNUM TYPE STRING,
WAPOS TYPE STRING,
LAUFN TYPE STRING,
OBKNR TYPE STRING,
REVNR TYPE STRING,
ADDAT TYPE STRING,
ADUHR TYPE STRING,
IPHAS TYPE STRING,
ILART TYPE STRING,
QMNUM TYPE STRING,
HISDA TYPE STRING,
AKKNZ TYPE STRING,
PLKNZ TYPE STRING,
AUART TYPE STRING,
AUTYP TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
KTEXT TYPE STRING,
LTEXT TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
CCKEY TYPE STRING,
KOSTV TYPE STRING,
STORT TYPE STRING,
SOWRK TYPE STRING,
ASTKZ TYPE STRING,
WAERS TYPE STRING,
ASTNR TYPE STRING,
STDAT TYPE STRING,
ESTNR TYPE STRING,
PHAS0 TYPE STRING,
PHAS1 TYPE STRING,
PHAS2 TYPE STRING,
PHAS3 TYPE STRING,
PDAT1 TYPE STRING,
PDAT2 TYPE STRING,
PDAT3 TYPE STRING,
IDAT1 TYPE STRING,
IDAT2 TYPE STRING,
IDAT3 TYPE STRING,
OBJID TYPE STRING,
VOGRP TYPE STRING,
LOEKZ TYPE STRING,
PLGKZ TYPE STRING,
KVEWE TYPE STRING,
KAPPL TYPE STRING,
KALSM TYPE STRING,
ZSCHL TYPE STRING,
ABKRS TYPE STRING,
KSTAR TYPE STRING,
KOSTL TYPE STRING,
SAKNR TYPE STRING,
SETNM TYPE STRING,
CYCLE TYPE STRING,
SDATE TYPE STRING,
SEQNR TYPE STRING,
USER0 TYPE STRING,
USER1 TYPE STRING,
USER2 TYPE STRING,
USER3 TYPE STRING,
USER4 TYPE STRING,
USER5 TYPE STRING,
USER6 TYPE STRING,
USER7 TYPE STRING,
USER8 TYPE STRING,
USER9 TYPE STRING,
OBJNR TYPE STRING,
PRCTR TYPE STRING,
PSPEL TYPE STRING,
SCOPE TYPE STRING,
PLINT TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
AKSTL TYPE STRING,
GLTRP TYPE STRING,
GSTRP TYPE STRING,
FTRMS TYPE STRING,
GLTRS TYPE STRING,
GSTRS TYPE STRING,
GSTRI TYPE STRING,
GETRI TYPE STRING,
GLTRI TYPE STRING,
FTRMI TYPE STRING,
FTRMP TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAW TYPE STRING,
PLNAL TYPE STRING,
PVERW TYPE STRING,
AUFPL TYPE STRING,
TERKZ TYPE STRING,
NTZUE TYPE STRING,
VORUE TYPE STRING,
GLUZS TYPE STRING,
GSUZS TYPE STRING,
TRMDT TYPE STRING,
GLUZP TYPE STRING,
GSUZP TYPE STRING,
GSUZI TYPE STRING,
GEUZI TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_25613_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_25613_STR-MANDT sy-vline
WA_U_25613_STR-AUFNR sy-vline
WA_U_25613_STR-ARTPR sy-vline
WA_U_25613_STR-PRIOK sy-vline
WA_U_25613_STR-EQUNR sy-vline
WA_U_25613_STR-BAUTL sy-vline
WA_U_25613_STR-ILOAN sy-vline
WA_U_25613_STR-ILOAI sy-vline
WA_U_25613_STR-ANLZU sy-vline
WA_U_25613_STR-IWERK sy-vline
WA_U_25613_STR-INGPR sy-vline
WA_U_25613_STR-APGRP sy-vline
WA_U_25613_STR-PM_OBJTY sy-vline
WA_U_25613_STR-GEWRK sy-vline
WA_U_25613_STR-KUNUM sy-vline
WA_U_25613_STR-ANING sy-vline
WA_U_25613_STR-GAUZT sy-vline
WA_U_25613_STR-GAUEH sy-vline
WA_U_25613_STR-ANLBD sy-vline
WA_U_25613_STR-ANLVD sy-vline
WA_U_25613_STR-ANLBZ sy-vline
WA_U_25613_STR-ANLVZ sy-vline
WA_U_25613_STR-INSPK sy-vline
WA_U_25613_STR-DATAN sy-vline
WA_U_25613_STR-WARPL sy-vline
WA_U_25613_STR-ABNUM sy-vline
WA_U_25613_STR-WAPOS sy-vline
WA_U_25613_STR-LAUFN sy-vline
WA_U_25613_STR-OBKNR sy-vline
WA_U_25613_STR-REVNR sy-vline
WA_U_25613_STR-ADDAT sy-vline
WA_U_25613_STR-ADUHR sy-vline
WA_U_25613_STR-IPHAS sy-vline
WA_U_25613_STR-ILART sy-vline
WA_U_25613_STR-QMNUM sy-vline
WA_U_25613_STR-HISDA sy-vline
WA_U_25613_STR-AKKNZ sy-vline
WA_U_25613_STR-PLKNZ sy-vline
WA_U_25613_STR-AUART sy-vline
WA_U_25613_STR-AUTYP sy-vline
WA_U_25613_STR-ERNAM sy-vline
WA_U_25613_STR-ERDAT sy-vline
WA_U_25613_STR-AENAM sy-vline
WA_U_25613_STR-AEDAT sy-vline
WA_U_25613_STR-KTEXT sy-vline
WA_U_25613_STR-LTEXT sy-vline
WA_U_25613_STR-BUKRS sy-vline
WA_U_25613_STR-WERKS sy-vline
WA_U_25613_STR-GSBER sy-vline
WA_U_25613_STR-KOKRS sy-vline
WA_U_25613_STR-CCKEY sy-vline
WA_U_25613_STR-KOSTV sy-vline
WA_U_25613_STR-STORT sy-vline
WA_U_25613_STR-SOWRK sy-vline
WA_U_25613_STR-ASTKZ sy-vline
WA_U_25613_STR-WAERS sy-vline
WA_U_25613_STR-ASTNR sy-vline
WA_U_25613_STR-STDAT sy-vline
WA_U_25613_STR-ESTNR sy-vline
WA_U_25613_STR-PHAS0 sy-vline
WA_U_25613_STR-PHAS1 sy-vline
WA_U_25613_STR-PHAS2 sy-vline
WA_U_25613_STR-PHAS3 sy-vline
WA_U_25613_STR-PDAT1 sy-vline
WA_U_25613_STR-PDAT2 sy-vline
WA_U_25613_STR-PDAT3 sy-vline
WA_U_25613_STR-IDAT1 sy-vline
WA_U_25613_STR-IDAT2 sy-vline
WA_U_25613_STR-IDAT3 sy-vline
WA_U_25613_STR-OBJID sy-vline
WA_U_25613_STR-VOGRP sy-vline
WA_U_25613_STR-LOEKZ sy-vline
WA_U_25613_STR-PLGKZ sy-vline
WA_U_25613_STR-KVEWE sy-vline
WA_U_25613_STR-KAPPL sy-vline
WA_U_25613_STR-KALSM sy-vline
WA_U_25613_STR-ZSCHL sy-vline
WA_U_25613_STR-ABKRS sy-vline
WA_U_25613_STR-KSTAR sy-vline
WA_U_25613_STR-KOSTL sy-vline
WA_U_25613_STR-SAKNR sy-vline
WA_U_25613_STR-SETNM sy-vline
WA_U_25613_STR-CYCLE sy-vline
WA_U_25613_STR-SDATE sy-vline
WA_U_25613_STR-SEQNR sy-vline
WA_U_25613_STR-USER0 sy-vline
WA_U_25613_STR-USER1 sy-vline
WA_U_25613_STR-USER2 sy-vline
WA_U_25613_STR-USER3 sy-vline
WA_U_25613_STR-USER4 sy-vline
WA_U_25613_STR-USER5 sy-vline
WA_U_25613_STR-USER6 sy-vline
WA_U_25613_STR-USER7 sy-vline
WA_U_25613_STR-USER8 sy-vline
WA_U_25613_STR-USER9 sy-vline
WA_U_25613_STR-OBJNR sy-vline
WA_U_25613_STR-PRCTR sy-vline
WA_U_25613_STR-PSPEL sy-vline
WA_U_25613_STR-SCOPE sy-vline
WA_U_25613_STR-PLINT sy-vline
WA_U_25613_STR-KDAUF sy-vline
WA_U_25613_STR-KDPOS sy-vline
WA_U_25613_STR-AKSTL sy-vline
WA_U_25613_STR-GLTRP sy-vline
WA_U_25613_STR-GSTRP sy-vline
WA_U_25613_STR-FTRMS sy-vline
WA_U_25613_STR-GLTRS sy-vline
WA_U_25613_STR-GSTRS sy-vline
WA_U_25613_STR-GSTRI sy-vline
WA_U_25613_STR-GETRI sy-vline
WA_U_25613_STR-GLTRI sy-vline
WA_U_25613_STR-FTRMI sy-vline
WA_U_25613_STR-FTRMP sy-vline
WA_U_25613_STR-PLNTY sy-vline
WA_U_25613_STR-PLNNR sy-vline
WA_U_25613_STR-PLNAW sy-vline
WA_U_25613_STR-PLNAL sy-vline
WA_U_25613_STR-PVERW sy-vline
WA_U_25613_STR-AUFPL sy-vline
WA_U_25613_STR-TERKZ sy-vline
WA_U_25613_STR-NTZUE sy-vline
WA_U_25613_STR-VORUE sy-vline
WA_U_25613_STR-GLUZS sy-vline
WA_U_25613_STR-GSUZS sy-vline
WA_U_25613_STR-TRMDT sy-vline
WA_U_25613_STR-GLUZP sy-vline
WA_U_25613_STR-GSUZP sy-vline
WA_U_25613_STR-GSUZI sy-vline
WA_U_25613_STR-GEUZI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.