ABAP Select data from SAP table U_25637 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_25637 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_25637. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_25637 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_25637 TYPE STANDARD TABLE OF U_25637,
      WA_U_25637 TYPE U_25637,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_25637> TYPE U_25637.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_25637.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_25637
  INTO TABLE IT_U_25637.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_25637
*  INTO TABLE @DATA(IT_U_256372).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_25637 INDEX 1 INTO DATA(WA_U_256372).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_25637 ASSIGNING <U_25637>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_25637>-MANDT = 1.
<U_25637>-PARVW = 1.
<U_25637>-PARNR = 1.
<U_25637>-OBJNR = 1.
<U_25637>-QMNUM = 1.
ENDLOOP.

LOOP AT IT_U_25637 INTO WA_U_25637.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_25637-COUNTER, sy-vline,
WA_U_25637-OBTYP, sy-vline,
WA_U_25637-INHER, sy-vline,
WA_U_25637-ERDAT, sy-vline,
WA_U_25637-ERZEIT, sy-vline,
WA_U_25637-ERNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_25637 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_25637 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_25637 INTO WA_U_25637. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25637-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25637-PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25637-PARNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25637-PARNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25637-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25637-QMNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_25637_STR,
MANDT TYPE STRING,
PARVW TYPE STRING,
PARNR TYPE STRING,
OBJNR TYPE STRING,
QMNUM TYPE STRING,
COUNTER TYPE STRING,
OBTYP TYPE STRING,
INHER TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
KZLOESCH TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_25637_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_25637_STR-MANDT sy-vline
WA_U_25637_STR-PARVW sy-vline
WA_U_25637_STR-PARNR sy-vline
WA_U_25637_STR-OBJNR sy-vline
WA_U_25637_STR-QMNUM sy-vline
WA_U_25637_STR-COUNTER sy-vline
WA_U_25637_STR-OBTYP sy-vline
WA_U_25637_STR-INHER sy-vline
WA_U_25637_STR-ERDAT sy-vline
WA_U_25637_STR-ERZEIT sy-vline
WA_U_25637_STR-ERNAM sy-vline
WA_U_25637_STR-AEDAT sy-vline
WA_U_25637_STR-AEZEIT sy-vline
WA_U_25637_STR-AENAM sy-vline
WA_U_25637_STR-KZLOESCH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.