ABAP Select data from SAP table U_26183 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_26183 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_26183. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_26183 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_26183 TYPE STANDARD TABLE OF U_26183,
      WA_U_26183 TYPE U_26183,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_26183> TYPE U_26183.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_26183.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_26183
  INTO TABLE IT_U_26183.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_26183
*  INTO TABLE @DATA(IT_U_261832).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_26183 INDEX 1 INTO DATA(WA_U_261832).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_26183 ASSIGNING <U_26183>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_26183>-MANDT = 1.
<U_26183>-BTYPB = 1.
<U_26183>-BLNRB = 1.
<U_26183>-BPOSB = 1.
<U_26183>-BTYPA = 1.
ENDLOOP.

LOOP AT IT_U_26183 INTO WA_U_26183.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_26183-BLNRA, sy-vline,
WA_U_26183-BPOSA, sy-vline,
WA_U_26183-GABLV, sy-vline,
WA_U_26183-MATNR, sy-vline,
WA_U_26183-PMENB, sy-vline,
WA_U_26183-PEINB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_26183 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_26183 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_26183 INTO WA_U_26183. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BLNRB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_26183-BLNRB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-BLNRB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BLNRA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_26183-BLNRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-BLNRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_U_26183-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-PEINB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-PEINB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-IEINB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-IEINB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-PEINA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-PEINA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-IEINA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-IEINA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EINCD CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-EINCD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-EINCD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EINFT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-EINFT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-EINFT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EINVT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-EINVT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-EINVT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EINPA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_26183-EINPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-EINPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ABNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_26183-ABNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26183-ABNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_26183_STR,
MANDT TYPE STRING,
BTYPB TYPE STRING,
BLNRB TYPE STRING,
BPOSB TYPE STRING,
BTYPA TYPE STRING,
BLNRA TYPE STRING,
BPOSA TYPE STRING,
GABLV TYPE STRING,
MATNR TYPE STRING,
PMENB TYPE STRING,
PEINB TYPE STRING,
IMNGB TYPE STRING,
IEINB TYPE STRING,
PMENA TYPE STRING,
PEINA TYPE STRING,
IMNGA TYPE STRING,
IEINA TYPE STRING,
BARTV TYPE STRING,
MNGCD TYPE STRING,
EINCD TYPE STRING,
MNGFT TYPE STRING,
EINFT TYPE STRING,
VERVF TYPE STRING,
MNGVT TYPE STRING,
EINVT TYPE STRING,
MNGPA TYPE STRING,
EINPA TYPE STRING,
WERKA TYPE STRING,
ABNTP TYPE STRING,
ABNNR TYPE STRING,
KZFSA TYPE STRING,
KZVST TYPE STRING,
STSVE TYPE STRING,
ERFDAT TYPE STRING,
ERFUSR TYPE STRING,
ERFZT TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_26183_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_26183_STR-MANDT sy-vline
WA_U_26183_STR-BTYPB sy-vline
WA_U_26183_STR-BLNRB sy-vline
WA_U_26183_STR-BPOSB sy-vline
WA_U_26183_STR-BTYPA sy-vline
WA_U_26183_STR-BLNRA sy-vline
WA_U_26183_STR-BPOSA sy-vline
WA_U_26183_STR-GABLV sy-vline
WA_U_26183_STR-MATNR sy-vline
WA_U_26183_STR-PMENB sy-vline
WA_U_26183_STR-PEINB sy-vline
WA_U_26183_STR-IMNGB sy-vline
WA_U_26183_STR-IEINB sy-vline
WA_U_26183_STR-PMENA sy-vline
WA_U_26183_STR-PEINA sy-vline
WA_U_26183_STR-IMNGA sy-vline
WA_U_26183_STR-IEINA sy-vline
WA_U_26183_STR-BARTV sy-vline
WA_U_26183_STR-MNGCD sy-vline
WA_U_26183_STR-EINCD sy-vline
WA_U_26183_STR-MNGFT sy-vline
WA_U_26183_STR-EINFT sy-vline
WA_U_26183_STR-VERVF sy-vline
WA_U_26183_STR-MNGVT sy-vline
WA_U_26183_STR-EINVT sy-vline
WA_U_26183_STR-MNGPA sy-vline
WA_U_26183_STR-EINPA sy-vline
WA_U_26183_STR-WERKA sy-vline
WA_U_26183_STR-ABNTP sy-vline
WA_U_26183_STR-ABNNR sy-vline
WA_U_26183_STR-KZFSA sy-vline
WA_U_26183_STR-KZVST sy-vline
WA_U_26183_STR-STSVE sy-vline
WA_U_26183_STR-ERFDAT sy-vline
WA_U_26183_STR-ERFUSR sy-vline
WA_U_26183_STR-ERFZT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.