ABAP Select data from SAP table UABW_S_EXCCS_1PCQM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UABW_S_EXCCS_1PCQM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UABW_S_EXCCS_1PCQM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UABW_S_EXCCS_1PCQM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UABW_S_EXCCS_1PCQM TYPE STANDARD TABLE OF UABW_S_EXCCS_1PCQM,
      WA_UABW_S_EXCCS_1PCQM TYPE UABW_S_EXCCS_1PCQM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UABW_S_EXCCS_1PCQM> TYPE UABW_S_EXCCS_1PCQM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UABW_S_EXCCS_1PCQM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UABW_S_EXCCS_1PCQM
  INTO TABLE IT_UABW_S_EXCCS_1PCQM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UABW_S_EXCCS_1PCQM
*  INTO TABLE @DATA(IT_UABW_S_EXCCS_1PCQM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UABW_S_EXCCS_1PCQM INDEX 1 INTO DATA(WA_UABW_S_EXCCS_1PCQM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UABW_S_EXCCS_1PCQM ASSIGNING <UABW_S_EXCCS_1PCQM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UABW_S_EXCCS_1PCQM>-ACC_RECORDMODE = 1.
<UABW_S_EXCCS_1PCQM>-FINB_CHNG_TSTAMP = 1.
<UABW_S_EXCCS_1PCQM>-FOBJ_OBJECT_ID = 1.
<UABW_S_EXCCS_1PCQM>-UAB_COSTCOMSPLIT = 1.
<UABW_S_EXCCS_1PCQM>-/1FB/CCOMPSTRUC = 1.
ENDLOOP.

LOOP AT IT_UABW_S_EXCCS_1PCQM INTO WA_UABW_S_EXCCS_1PCQM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UABW_S_EXCCS_1PCQM-/1FB/COSTCOMP, sy-vline,
WA_UABW_S_EXCCS_1PCQM-FISCYEAR, sy-vline,
WA_UABW_S_EXCCS_1PCQM-FISCVARNT, sy-vline,
WA_UABW_S_EXCCS_1PCQM-/1FB/CECSCLVA, sy-vline,
WA_UABW_S_EXCCS_1PCQM-/1FB/CECSCLFX, sy-vline,
WA_UABW_S_EXCCS_1PCQM-/1FB/CEETTC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UABW_S_EXCCS_1PCQM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UABW_S_EXCCS_1PCQM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UABW_S_EXCCS_1PCQM INTO WA_UABW_S_EXCCS_1PCQM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field FISCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_UABW_S_EXCCS_1PCQM-FISCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UABW_S_EXCCS_1PCQM-FISCYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UABW_S_EXCCS_1PCQM-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UABW_S_EXCCS_1PCQM-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UABW_S_EXCCS_1PCQM_STR,
ACC_RECORDMODE TYPE STRING,
FINB_CHNG_TSTAMP TYPE STRING,
FOBJ_OBJECT_ID TYPE STRING,
UAB_COSTCOMSPLIT TYPE STRING,
/1FB/CCOMPSTRUC TYPE STRING,
/1FB/COSTCOMP TYPE STRING,
FISCYEAR TYPE STRING,
FISCVARNT TYPE STRING,
/1FB/CECSCLVA TYPE STRING,
/1FB/CECSCLFX TYPE STRING,
/1FB/CEETTC TYPE STRING,
/1FB/CEETTCM TYPE STRING,
/1FB/CECSCL TYPE STRING,
/1FB/CEBQRQF TYPE STRING,
/1FB/CELSIZEM TYPE STRING,
/1FB/LOTSIZE TYPE STRING,
/1FB/CECLS TYPE STRING,
/1FB/CECSTARA TYPE STRING,
/1FB/CECLSM TYPE STRING,
/1FB/CERQBQF TYPE STRING,
/1FB/CEPRCS4 TYPE STRING,
/1FB/CERVPERC TYPE STRING,
/1FB/CERVPMRG TYPE STRING,
/1FB/CEPRCS5 TYPE STRING,
/1FB/CEBQRQM TYPE STRING,
/1FB/CERVSVOL TYPE STRING,
/1FB/CEPRSIZE TYPE STRING,
/1FB/CEEAUFOR TYPE STRING,
/1FB/CEESTPR TYPE STRING,
CURRENCY TYPE STRING,
UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_UABW_S_EXCCS_1PCQM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-ACC_RECORDMODE sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-FINB_CHNG_TSTAMP sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-FOBJ_OBJECT_ID sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-UAB_COSTCOMSPLIT sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CCOMPSTRUC sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/COSTCOMP sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-FISCYEAR sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-FISCVARNT sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECSCLVA sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECSCLFX sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEETTC sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEETTCM sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECSCL sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEBQRQF sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CELSIZEM sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/LOTSIZE sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECLS sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECSTARA sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CECLSM sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CERQBQF sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEPRCS4 sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CERVPERC sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CERVPMRG sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEPRCS5 sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEBQRQM sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CERVSVOL sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEPRSIZE sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEEAUFOR sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-/1FB/CEESTPR sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-CURRENCY sy-vline
WA_UABW_S_EXCCS_1PCQM_STR-UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.