ABAP Select data from SAP table UAINVT2000 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UAINVT2000 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UAINVT2000. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UAINVT2000 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UAINVT2000 TYPE STANDARD TABLE OF UAINVT2000, WA_UAINVT2000 TYPE UAINVT2000, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UAINVT2000> TYPE UAINVT2000. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UAINVT2000. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UAINVT2000 INTO TABLE IT_UAINVT2000. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UAINVT2000 * INTO TABLE @DATA(IT_UAINVT20002). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UAINVT2000 INDEX 1 INTO DATA(WA_UAINVT20002). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UAINVT2000 ASSIGNING <UAINVT2000>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UAINVT2000>-METANAME = 1.
<UAINVT2000>-ACC_CONFIG = 1.
<UAINVT2000>-FIELDNAME = 1.
<UAINVT2000>-INFOOBJECT = 1.
<UAINVT2000>-ROLE = 1.
ENDLOOP. LOOP AT IT_UAINVT2000 INTO WA_UAINVT2000. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UAINVT2000-ROLLNAME, sy-vline,
WA_UAINVT2000-X_IS_KYF, sy-vline,
WA_UAINVT2000-REF_FIELDNAME, sy-vline,
WA_UAINVT2000-REF_INFOOBJECT, sy-vline,
WA_UAINVT2000-REF_ROLE, sy-vline,
WA_UAINVT2000-REF_ROLLNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UAINVT2000 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UAINVT2000 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UAINVT2000 INTO WA_UAINVT2000. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UAINVT2000_STR,
METANAME TYPE STRING,
ACC_CONFIG TYPE STRING,
FIELDNAME TYPE STRING,
INFOOBJECT TYPE STRING,
ROLE TYPE STRING,
ROLLNAME TYPE STRING,
X_IS_KYF TYPE STRING,
REF_FIELDNAME TYPE STRING,
REF_INFOOBJECT TYPE STRING,
REF_ROLE TYPE STRING,
REF_ROLLNAME TYPE STRING,
IS_INTEGRATED TYPE STRING,
DATA_ORIGIN TYPE STRING,
DSFIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_UAINVT2000_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UAINVT2000_STR-METANAME sy-vline
WA_UAINVT2000_STR-ACC_CONFIG sy-vline
WA_UAINVT2000_STR-FIELDNAME sy-vline
WA_UAINVT2000_STR-INFOOBJECT sy-vline
WA_UAINVT2000_STR-ROLE sy-vline
WA_UAINVT2000_STR-ROLLNAME sy-vline
WA_UAINVT2000_STR-X_IS_KYF sy-vline
WA_UAINVT2000_STR-REF_FIELDNAME sy-vline
WA_UAINVT2000_STR-REF_INFOOBJECT sy-vline
WA_UAINVT2000_STR-REF_ROLE sy-vline
WA_UAINVT2000_STR-REF_ROLLNAME sy-vline
WA_UAINVT2000_STR-IS_INTEGRATED sy-vline
WA_UAINVT2000_STR-DATA_ORIGIN sy-vline
WA_UAINVT2000_STR-DSFIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.