ABAP Select data from SAP table UJR_S_DIM_HANDLER into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UJR_S_DIM_HANDLER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UJR_S_DIM_HANDLER. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UJR_S_DIM_HANDLER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UJR_S_DIM_HANDLER TYPE STANDARD TABLE OF UJR_S_DIM_HANDLER, WA_UJR_S_DIM_HANDLER TYPE UJR_S_DIM_HANDLER, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UJR_S_DIM_HANDLER> TYPE UJR_S_DIM_HANDLER. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UJR_S_DIM_HANDLER. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UJR_S_DIM_HANDLER INTO TABLE IT_UJR_S_DIM_HANDLER. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UJR_S_DIM_HANDLER * INTO TABLE @DATA(IT_UJR_S_DIM_HANDLER2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UJR_S_DIM_HANDLER INDEX 1 INTO DATA(WA_UJR_S_DIM_HANDLER2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UJR_S_DIM_HANDLER ASSIGNING <UJR_S_DIM_HANDLER>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UJR_S_DIM_HANDLER>-DIM_OBJ = 1.
<UJR_S_DIM_HANDLER>-DIMENSION = 1.
<UJR_S_DIM_HANDLER>-DESCRIPTION = 1.
<UJR_S_DIM_HANDLER>-DIM_TYPE = 1.
<UJR_S_DIM_HANDLER>-DIM_TYPE_INDEX = 1.
ENDLOOP. LOOP AT IT_UJR_S_DIM_HANDLER INTO WA_UJR_S_DIM_HANDLER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UJR_S_DIM_HANDLER-DIM_TYPE_DESC, sy-vline,
WA_UJR_S_DIM_HANDLER-REF_DIM, sy-vline,
WA_UJR_S_DIM_HANDLER-T_ATTR, sy-vline,
WA_UJR_S_DIM_HANDLER-SERVER_VERSION, sy-vline,
WA_UJR_S_DIM_HANDLER-TECH_NAME, sy-vline,
WA_UJR_S_DIM_HANDLER-FILE_VERSION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UJR_S_DIM_HANDLER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UJR_S_DIM_HANDLER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UJR_S_DIM_HANDLER INTO WA_UJR_S_DIM_HANDLER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UJR_S_DIM_HANDLER_STR,
DIM_OBJ TYPE STRING,
DIMENSION TYPE STRING,
DESCRIPTION TYPE STRING,
DIM_TYPE TYPE STRING,
DIM_TYPE_INDEX TYPE STRING,
DIM_TYPE_DESC TYPE STRING,
REF_DIM TYPE STRING,
T_ATTR TYPE STRING,
SERVER_VERSION TYPE STRING,
TECH_NAME TYPE STRING,
FILE_VERSION TYPE STRING,
FILE_LOCK TYPE STRING,
FILE_PATH TYPE STRING,
PROCESS_STATE TYPE STRING,
LOCKED_BY TYPE STRING,
NUM_HIER TYPE STRING,
CAPTION TYPE STRING,
HIER_TIME_DEP TYPE STRING,
PROCESS_DATE TYPE STRING,
PROCESS_TIME TYPE STRING,
STRUC_MODIF_DATE TYPE STRING,
STRUC_MODIF_TIME TYPE STRING,
MBR_MODIF_DATE TYPE STRING,
MBR_MODIF_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_UJR_S_DIM_HANDLER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UJR_S_DIM_HANDLER_STR-DIM_OBJ sy-vline
WA_UJR_S_DIM_HANDLER_STR-DIMENSION sy-vline
WA_UJR_S_DIM_HANDLER_STR-DESCRIPTION sy-vline
WA_UJR_S_DIM_HANDLER_STR-DIM_TYPE sy-vline
WA_UJR_S_DIM_HANDLER_STR-DIM_TYPE_INDEX sy-vline
WA_UJR_S_DIM_HANDLER_STR-DIM_TYPE_DESC sy-vline
WA_UJR_S_DIM_HANDLER_STR-REF_DIM sy-vline
WA_UJR_S_DIM_HANDLER_STR-T_ATTR sy-vline
WA_UJR_S_DIM_HANDLER_STR-SERVER_VERSION sy-vline
WA_UJR_S_DIM_HANDLER_STR-TECH_NAME sy-vline
WA_UJR_S_DIM_HANDLER_STR-FILE_VERSION sy-vline
WA_UJR_S_DIM_HANDLER_STR-FILE_LOCK sy-vline
WA_UJR_S_DIM_HANDLER_STR-FILE_PATH sy-vline
WA_UJR_S_DIM_HANDLER_STR-PROCESS_STATE sy-vline
WA_UJR_S_DIM_HANDLER_STR-LOCKED_BY sy-vline
WA_UJR_S_DIM_HANDLER_STR-NUM_HIER sy-vline
WA_UJR_S_DIM_HANDLER_STR-CAPTION sy-vline
WA_UJR_S_DIM_HANDLER_STR-HIER_TIME_DEP sy-vline
WA_UJR_S_DIM_HANDLER_STR-PROCESS_DATE sy-vline
WA_UJR_S_DIM_HANDLER_STR-PROCESS_TIME sy-vline
WA_UJR_S_DIM_HANDLER_STR-STRUC_MODIF_DATE sy-vline
WA_UJR_S_DIM_HANDLER_STR-STRUC_MODIF_TIME sy-vline
WA_UJR_S_DIM_HANDLER_STR-MBR_MODIF_DATE sy-vline
WA_UJR_S_DIM_HANDLER_STR-MBR_MODIF_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.