ABAP Select data from SAP table UMR_RI128 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UMR_RI128 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UMR_RI128. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UMR_RI128 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UMR_RI128 TYPE STANDARD TABLE OF UMR_RI128, WA_UMR_RI128 TYPE UMR_RI128, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UMR_RI128> TYPE UMR_RI128. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UMR_RI128. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UMR_RI128 INTO TABLE IT_UMR_RI128. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UMR_RI128 * INTO TABLE @DATA(IT_UMR_RI1282). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UMR_RI128 INDEX 1 INTO DATA(WA_UMR_RI1282). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UMR_RI128 ASSIGNING <UMR_RI128>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UMR_RI128>-MANDT = 1.
<UMR_RI128>-APP = 1.
<UMR_RI128>-APPKEY = 1.
<UMR_RI128>-MEAS = 1.
<UMR_RI128>-TARPER = 1.
ENDLOOP. LOOP AT IT_UMR_RI128 INTO WA_UMR_RI128. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UMR_RI128-CURPER, sy-vline,
WA_UMR_RI128-RISK, sy-vline,
WA_UMR_RI128-COL, sy-vline,
WA_UMR_RI128-RACTIVITY, sy-vline,
WA_UMR_RI128-DEVIATION, sy-vline,
WA_UMR_RI128-UNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UMR_RI128 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UMR_RI128 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UMR_RI128 INTO WA_UMR_RI128. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit PERI7, internal->external for field TARPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_UMR_RI128-TARPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMR_RI128-TARPER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PERI7, internal->external for field CURPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_UMR_RI128-CURPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMR_RI128-CURPER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UMR_RI128_STR,
MANDT TYPE STRING,
APP TYPE STRING,
APPKEY TYPE STRING,
MEAS TYPE STRING,
TARPER TYPE STRING,
CURPER TYPE STRING,
RISK TYPE STRING,
COL TYPE STRING,
RACTIVITY TYPE STRING,
DEVIATION TYPE STRING,
UNIT TYPE STRING,
VALTYPE TYPE STRING,
MEASSCALE TYPE STRING,
MEASDEC TYPE STRING,
SIGNREV TYPE STRING,
DESCRIPTION TYPE STRING,
TSTPNM TYPE STRING,
TIMESTMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_UMR_RI128_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UMR_RI128_STR-MANDT sy-vline
WA_UMR_RI128_STR-APP sy-vline
WA_UMR_RI128_STR-APPKEY sy-vline
WA_UMR_RI128_STR-MEAS sy-vline
WA_UMR_RI128_STR-TARPER sy-vline
WA_UMR_RI128_STR-CURPER sy-vline
WA_UMR_RI128_STR-RISK sy-vline
WA_UMR_RI128_STR-COL sy-vline
WA_UMR_RI128_STR-RACTIVITY sy-vline
WA_UMR_RI128_STR-DEVIATION sy-vline
WA_UMR_RI128_STR-UNIT sy-vline
WA_UMR_RI128_STR-VALTYPE sy-vline
WA_UMR_RI128_STR-MEASSCALE sy-vline
WA_UMR_RI128_STR-MEASDEC sy-vline
WA_UMR_RI128_STR-SIGNREV sy-vline
WA_UMR_RI128_STR-DESCRIPTION sy-vline
WA_UMR_RI128_STR-TSTPNM sy-vline
WA_UMR_RI128_STR-TIMESTMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.