ABAP Select data from SAP table UPE_YS_RSHIE_INFO_TRANSFER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPE_YS_RSHIE_INFO_TRANSFER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPE_YS_RSHIE_INFO_TRANSFER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPE_YS_RSHIE_INFO_TRANSFER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPE_YS_RSHIE_INFO_TRANSFER TYPE STANDARD TABLE OF UPE_YS_RSHIE_INFO_TRANSFER,
      WA_UPE_YS_RSHIE_INFO_TRANSFER TYPE UPE_YS_RSHIE_INFO_TRANSFER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPE_YS_RSHIE_INFO_TRANSFER> TYPE UPE_YS_RSHIE_INFO_TRANSFER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPE_YS_RSHIE_INFO_TRANSFER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPE_YS_RSHIE_INFO_TRANSFER
  INTO TABLE IT_UPE_YS_RSHIE_INFO_TRANSFER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPE_YS_RSHIE_INFO_TRANSFER
*  INTO TABLE @DATA(IT_UPE_YS_RSHIE_INFO_TRANSFER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPE_YS_RSHIE_INFO_TRANSFER INDEX 1 INTO DATA(WA_UPE_YS_RSHIE_INFO_TRANSFER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPE_YS_RSHIE_INFO_TRANSFER ASSIGNING <UPE_YS_RSHIE_INFO_TRANSFER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPE_YS_RSHIE_INFO_TRANSFER>-IOBJNM = 1.
<UPE_YS_RSHIE_INFO_TRANSFER>-OBJVERS = 1.
<UPE_YS_RSHIE_INFO_TRANSFER>-HIETYPE = 1.
<UPE_YS_RSHIE_INFO_TRANSFER>-HIENM = 1.
<UPE_YS_RSHIE_INFO_TRANSFER>-VERSION = 1.
ENDLOOP.

LOOP AT IT_UPE_YS_RSHIE_INFO_TRANSFER INTO WA_UPE_YS_RSHIE_INFO_TRANSFER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPE_YS_RSHIE_INFO_TRANSFER-DATETO, sy-vline,
WA_UPE_YS_RSHIE_INFO_TRANSFER-DATEFROM, sy-vline,
WA_UPE_YS_RSHIE_INFO_TRANSFER-OBJSTAT, sy-vline,
WA_UPE_YS_RSHIE_INFO_TRANSFER-ACTIVFL, sy-vline,
WA_UPE_YS_RSHIE_INFO_TRANSFER-HIENDTFL, sy-vline,
WA_UPE_YS_RSHIE_INFO_TRANSFER-CONSISTENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPE_YS_RSHIE_INFO_TRANSFER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPE_YS_RSHIE_INFO_TRANSFER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPE_YS_RSHIE_INFO_TRANSFER INTO WA_UPE_YS_RSHIE_INFO_TRANSFER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_UPE_YS_RSHIE_INFO_TRANSFER-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPE_YS_RSHIE_INFO_TRANSFER-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPE_YS_RSHIE_INFO_TRANSFER_STR,
IOBJNM TYPE STRING,
OBJVERS TYPE STRING,
HIETYPE TYPE STRING,
HIENM TYPE STRING,
VERSION TYPE STRING,
DATETO TYPE STRING,
DATEFROM TYPE STRING,
OBJSTAT TYPE STRING,
ACTIVFL TYPE STRING,
HIENDTFL TYPE STRING,
CONSISTENT TYPE STRING,
LANGU TYPE STRING,
TXTSH TYPE STRING,
TXTMD TYPE STRING,
TXTLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPE_YS_RSHIE_INFO_TRANSFER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-IOBJNM sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-OBJVERS sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-HIETYPE sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-HIENM sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-VERSION sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-DATETO sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-DATEFROM sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-OBJSTAT sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-ACTIVFL sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-HIENDTFL sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-CONSISTENT sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-LANGU sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-TXTSH sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-TXTMD sy-vline
WA_UPE_YS_RSHIE_INFO_TRANSFER_STR-TXTLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.