ABAP Select data from SAP table UPOS_UDM_NETOBJ_VD_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPOS_UDM_NETOBJ_VD_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPOS_UDM_NETOBJ_VD_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UPOS_UDM_NETOBJ_VD_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UPOS_UDM_NETOBJ_VD_DATA TYPE STANDARD TABLE OF UPOS_UDM_NETOBJ_VD_DATA, WA_UPOS_UDM_NETOBJ_VD_DATA TYPE UPOS_UDM_NETOBJ_VD_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UPOS_UDM_NETOBJ_VD_DATA> TYPE UPOS_UDM_NETOBJ_VD_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UPOS_UDM_NETOBJ_VD_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UPOS_UDM_NETOBJ_VD_DATA INTO TABLE IT_UPOS_UDM_NETOBJ_VD_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UPOS_UDM_NETOBJ_VD_DATA * INTO TABLE @DATA(IT_UPOS_UDM_NETOBJ_VD_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UPOS_UDM_NETOBJ_VD_DATA INDEX 1 INTO DATA(WA_UPOS_UDM_NETOBJ_VD_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UPOS_UDM_NETOBJ_VD_DATA ASSIGNING <UPOS_UDM_NETOBJ_VD_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPOS_UDM_NETOBJ_VD_DATA>-EFFECTIVE_TO = 1.
<UPOS_UDM_NETOBJ_VD_DATA>-NETOBJ_STATUS = 1.
<UPOS_UDM_NETOBJ_VD_DATA>-BUKRS = 1.
<UPOS_UDM_NETOBJ_VD_DATA>-COST_CENTRE = 1.
<UPOS_UDM_NETOBJ_VD_DATA>-OP_FL = 1.
ENDLOOP. LOOP AT IT_UPOS_UDM_NETOBJ_VD_DATA INTO WA_UPOS_UDM_NETOBJ_VD_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UPOS_UDM_NETOBJ_VD_DATA-PN_MEAS_GRP, sy-vline,
WA_UPOS_UDM_NETOBJ_VD_DATA-OPTIONAL, sy-vline,
WA_UPOS_UDM_NETOBJ_VD_DATA-PRD_MTH_CD, sy-vline,
WA_UPOS_UDM_NETOBJ_VD_DATA-OPERATOR, sy-vline,
WA_UPOS_UDM_NETOBJ_VD_DATA-PSPNR, sy-vline,
WA_UPOS_UDM_NETOBJ_VD_DATA-GHO_WELLCLASS_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPOS_UDM_NETOBJ_VD_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPOS_UDM_NETOBJ_VD_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPOS_UDM_NETOBJ_VD_DATA INTO WA_UPOS_UDM_NETOBJ_VD_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field COST_CENTRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOS_UDM_NETOBJ_VD_DATA-COST_CENTRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_NETOBJ_VD_DATA-COST_CENTRE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OPERATOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOS_UDM_NETOBJ_VD_DATA-OPERATOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_NETOBJ_VD_DATA-OPERATOR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_UPOS_UDM_NETOBJ_VD_DATA-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_NETOBJ_VD_DATA-PSPNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOS_UDM_NETOBJ_VD_DATA-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_NETOBJ_VD_DATA-PLNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOS_UDM_NETOBJ_VD_DATA-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_NETOBJ_VD_DATA-PLNAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPOS_UDM_NETOBJ_VD_DATA_STR,
EFFECTIVE_TO TYPE STRING,
NETOBJ_STATUS TYPE STRING,
BUKRS TYPE STRING,
COST_CENTRE TYPE STRING,
OP_FL TYPE STRING,
PN_MEAS_GRP TYPE STRING,
OPTIONAL TYPE STRING,
PRD_MTH_CD TYPE STRING,
OPERATOR TYPE STRING,
PSPNR TYPE STRING,
GHO_WELLCLASS_ID TYPE STRING,
RLF_USAGE_FL_MTR TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
AUART TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPOS_UDM_NETOBJ_VD_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-EFFECTIVE_TO sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-NETOBJ_STATUS sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-BUKRS sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-COST_CENTRE sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-OP_FL sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PN_MEAS_GRP sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-OPTIONAL sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PRD_MTH_CD sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-OPERATOR sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PSPNR sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-GHO_WELLCLASS_ID sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-RLF_USAGE_FL_MTR sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PLNTY sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PLNNR sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-PLNAL sy-vline
WA_UPOS_UDM_NETOBJ_VD_DATA_STR-AUART sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.