ABAP Select data from SAP table UPS_S_OD_COMP_ANALYSIS_DEEP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPS_S_OD_COMP_ANALYSIS_DEEP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPS_S_OD_COMP_ANALYSIS_DEEP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UPS_S_OD_COMP_ANALYSIS_DEEP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UPS_S_OD_COMP_ANALYSIS_DEEP TYPE STANDARD TABLE OF UPS_S_OD_COMP_ANALYSIS_DEEP, WA_UPS_S_OD_COMP_ANALYSIS_DEEP TYPE UPS_S_OD_COMP_ANALYSIS_DEEP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UPS_S_OD_COMP_ANALYSIS_DEEP> TYPE UPS_S_OD_COMP_ANALYSIS_DEEP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UPS_S_OD_COMP_ANALYSIS_DEEP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UPS_S_OD_COMP_ANALYSIS_DEEP INTO TABLE IT_UPS_S_OD_COMP_ANALYSIS_DEEP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UPS_S_OD_COMP_ANALYSIS_DEEP * INTO TABLE @DATA(IT_UPS_S_OD_COMP_ANALYSIS_DEEP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UPS_S_OD_COMP_ANALYSIS_DEEP INDEX 1 INTO DATA(WA_UPS_S_OD_COMP_ANALYSIS_DEEP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UPS_S_OD_COMP_ANALYSIS_DEEP ASSIGNING <UPS_S_OD_COMP_ANALYSIS_DEEP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPS_S_OD_COMP_ANALYSIS_DEEP>-PRODUCTION_NETWORK = 1.
<UPS_S_OD_COMP_ANALYSIS_DEEP>-NETWORK_OBJECT = 1.
<UPS_S_OD_COMP_ANALYSIS_DEEP>-EFFECTIVE_FROM = 1.
<UPS_S_OD_COMP_ANALYSIS_DEEP>-EFFECTIVE_TO = 1.
<UPS_S_OD_COMP_ANALYSIS_DEEP>-ANALYSIS_BASIS = 1.
ENDLOOP. LOOP AT IT_UPS_S_OD_COMP_ANALYSIS_DEEP INTO WA_UPS_S_OD_COMP_ANALYSIS_DEEP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UPS_S_OD_COMP_ANALYSIS_DEEP-CHANGED_TST, sy-vline,
WA_UPS_S_OD_COMP_ANALYSIS_DEEP-SAMPLE_DATE, sy-vline,
WA_UPS_S_OD_COMP_ANALYSIS_DEEP-OVERRIDE_FLAG, sy-vline,
WA_UPS_S_OD_COMP_ANALYSIS_DEEP-CREATE_FLAG, sy-vline,
WA_UPS_S_OD_COMP_ANALYSIS_DEEP-AUTH_CREATE, sy-vline,
WA_UPS_S_OD_COMP_ANALYSIS_DEEP-AUTH_READ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPS_S_OD_COMP_ANALYSIS_DEEP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPS_S_OD_COMP_ANALYSIS_DEEP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPS_S_OD_COMP_ANALYSIS_DEEP INTO WA_UPS_S_OD_COMP_ANALYSIS_DEEP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TPLNR, internal->external for field PRODUCTION_NETWORK CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_UPS_S_OD_COMP_ANALYSIS_DEEP-PRODUCTION_NETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_COMP_ANALYSIS_DEEP-PRODUCTION_NETWORK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field NETWORK_OBJECT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_UPS_S_OD_COMP_ANALYSIS_DEEP-NETWORK_OBJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_COMP_ANALYSIS_DEEP-NETWORK_OBJECT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPS_S_OD_COMP_ANALYSIS_DEEP_STR,
PRODUCTION_NETWORK TYPE STRING,
NETWORK_OBJECT TYPE STRING,
EFFECTIVE_FROM TYPE STRING,
EFFECTIVE_TO TYPE STRING,
ANALYSIS_BASIS TYPE STRING,
CHANGED_TST TYPE STRING,
SAMPLE_DATE TYPE STRING,
OVERRIDE_FLAG TYPE STRING,
CREATE_FLAG TYPE STRING,
AUTH_CREATE TYPE STRING,
AUTH_READ TYPE STRING,
AUTH_UPDATE TYPE STRING,
AUTH_DELETE TYPE STRING,
INSPECTION_LOT TYPE STRING,
FDCCOMPANALYSISDETAILSET TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-PRODUCTION_NETWORK sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-NETWORK_OBJECT sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-EFFECTIVE_FROM sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-EFFECTIVE_TO sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-ANALYSIS_BASIS sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-CHANGED_TST sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-SAMPLE_DATE sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-OVERRIDE_FLAG sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-CREATE_FLAG sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-AUTH_CREATE sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-AUTH_READ sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-AUTH_UPDATE sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-AUTH_DELETE sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-INSPECTION_LOT sy-vline
WA_UPS_S_OD_COMP_ANALYSIS_DEEP_STR-FDCCOMPANALYSISDETAILSET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.