ABAP Select data from SAP table V_5UBA_COB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_5UBA_COB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_5UBA_COB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_5UBA_COB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_5UBA_COB TYPE STANDARD TABLE OF V_5UBA_COB,
      WA_V_5UBA_COB TYPE V_5UBA_COB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_5UBA_COB> TYPE V_5UBA_COB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_5UBA_COB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_5UBA_COB
  INTO TABLE IT_V_5UBA_COB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_5UBA_COB
*  INTO TABLE @DATA(IT_V_5UBA_COB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_5UBA_COB INDEX 1 INTO DATA(WA_V_5UBA_COB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_5UBA_COB ASSIGNING <V_5UBA_COB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_5UBA_COB>-MANDT = 1.
<V_5UBA_COB>-BAREA = 1.
<V_5UBA_COB>-BPLAN = 1.
<V_5UBA_COB>-ENDDA = 1.
<V_5UBA_COB>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_V_5UBA_COB INTO WA_V_5UBA_COB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_5UBA_COB-COBOK, sy-vline,
WA_V_5UBA_COB-LTEXT, sy-vline,
WA_V_5UBA_COB-BPCAT, sy-vline,
WA_V_5UBA_COB-PLTYP, sy-vline,
WA_V_5UBA_COB-CRENR, sy-vline,
WA_V_5UBA_COB-PLNNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_5UBA_COB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_5UBA_COB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_5UBA_COB INTO WA_V_5UBA_COB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_5UBA_COB_STR,
MANDT TYPE STRING,
BAREA TYPE STRING,
BPLAN TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
COBOK TYPE STRING,
LTEXT TYPE STRING,
BPCAT TYPE STRING,
PLTYP TYPE STRING,
CRENR TYPE STRING,
PLNNO TYPE STRING,
PLSTA TYPE STRING,
IMPUT TYPE STRING,
ERWTY TYPE STRING,
EEWTY TYPE STRING,
BSWTY TYPE STRING,
DEFER TYPE STRING,
FLXCR TYPE STRING,
GTLIF TYPE STRING,
LNCOD TYPE STRING,
PRWTY TYPE STRING,
TBWTY TYPE STRING,
INWTY TYPE STRING,
DEPYN TYPE STRING,
BENYN TYPE STRING,
EEBYN TYPE STRING,
CTGYN TYPE STRING,
INVYN TYPE STRING,
PREYN TYPE STRING,
PSTYN TYPE STRING,
CSTYN TYPE STRING,
CRDYN TYPE STRING,
COVYN TYPE STRING,
EECYN TYPE STRING,
ERCYN TYPE STRING,
VESYN TYPE STRING,
CSTCR TYPE STRING,
PTWTY TYPE STRING,
ERNOC TYPE STRING,
BTWTY TYPE STRING,
BEWTY TYPE STRING,
BPWTY TYPE STRING,
BRWTY TYPE STRING,
BONYN TYPE STRING,
PRDED TYPE STRING,
URLPL TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_5UBA_COB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_5UBA_COB_STR-MANDT sy-vline
WA_V_5UBA_COB_STR-BAREA sy-vline
WA_V_5UBA_COB_STR-BPLAN sy-vline
WA_V_5UBA_COB_STR-ENDDA sy-vline
WA_V_5UBA_COB_STR-BEGDA sy-vline
WA_V_5UBA_COB_STR-COBOK sy-vline
WA_V_5UBA_COB_STR-LTEXT sy-vline
WA_V_5UBA_COB_STR-BPCAT sy-vline
WA_V_5UBA_COB_STR-PLTYP sy-vline
WA_V_5UBA_COB_STR-CRENR sy-vline
WA_V_5UBA_COB_STR-PLNNO sy-vline
WA_V_5UBA_COB_STR-PLSTA sy-vline
WA_V_5UBA_COB_STR-IMPUT sy-vline
WA_V_5UBA_COB_STR-ERWTY sy-vline
WA_V_5UBA_COB_STR-EEWTY sy-vline
WA_V_5UBA_COB_STR-BSWTY sy-vline
WA_V_5UBA_COB_STR-DEFER sy-vline
WA_V_5UBA_COB_STR-FLXCR sy-vline
WA_V_5UBA_COB_STR-GTLIF sy-vline
WA_V_5UBA_COB_STR-LNCOD sy-vline
WA_V_5UBA_COB_STR-PRWTY sy-vline
WA_V_5UBA_COB_STR-TBWTY sy-vline
WA_V_5UBA_COB_STR-INWTY sy-vline
WA_V_5UBA_COB_STR-DEPYN sy-vline
WA_V_5UBA_COB_STR-BENYN sy-vline
WA_V_5UBA_COB_STR-EEBYN sy-vline
WA_V_5UBA_COB_STR-CTGYN sy-vline
WA_V_5UBA_COB_STR-INVYN sy-vline
WA_V_5UBA_COB_STR-PREYN sy-vline
WA_V_5UBA_COB_STR-PSTYN sy-vline
WA_V_5UBA_COB_STR-CSTYN sy-vline
WA_V_5UBA_COB_STR-CRDYN sy-vline
WA_V_5UBA_COB_STR-COVYN sy-vline
WA_V_5UBA_COB_STR-EECYN sy-vline
WA_V_5UBA_COB_STR-ERCYN sy-vline
WA_V_5UBA_COB_STR-VESYN sy-vline
WA_V_5UBA_COB_STR-CSTCR sy-vline
WA_V_5UBA_COB_STR-PTWTY sy-vline
WA_V_5UBA_COB_STR-ERNOC sy-vline
WA_V_5UBA_COB_STR-BTWTY sy-vline
WA_V_5UBA_COB_STR-BEWTY sy-vline
WA_V_5UBA_COB_STR-BPWTY sy-vline
WA_V_5UBA_COB_STR-BRWTY sy-vline
WA_V_5UBA_COB_STR-BONYN sy-vline
WA_V_5UBA_COB_STR-PRDED sy-vline
WA_V_5UBA_COB_STR-URLPL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.